Multialkali high sensitivity side-on PMT
Spectral range: 185-900 nm,
Peak sensitivity wavelength: 400nm
Glass UV Envelope

Photocathode Area Size 8 x 24 mm
Photocathode Material Multialkali
Window Material UV glass
Dynode Structure Circular-cage
Anode to Cathode Voltage 1250 V
Average Anode Current 0.1 mA
Anode to Cathode Supply Voltage 1000 V
Luminous Sensitivity Min. 140 μA/lm
Luminous Sensitivity Typ. 250 μA/lm
Radiant Sensitivity Typ. 74 mA/W
Anode Luminous Sensitivity Min. 400 A/lm
Anode Luminous Sensitivity Typ. 2500 A/lm
Anode Radiant Sensitivity Typ. 7.4e5 A/W
Anode Dark Current (after 30min.) Typ. 3 nA
Anode Dark Current (after 30min.) Max. 50 nA
Time Response Rise Time Typ. 2.2 ns
Time Response Transit Time Typ. 22 ns
1,299.00
Multialkali high sensitivity side-on PMT
Spectral range: 185-900 nm,
Peak sensitivity wavelength: 400nm
Glass UV Envelope

Photocathode Area Size 8 x 24 mm
Photocathode Material Multialkali
Window Material UV glass
Dynode Structure Circular-cage
Anode to Cathode Voltage 1250 V
Average Anode Current 0.1 mA
Anode to Cathode Supply Voltage 1000 V
Luminous Sensitivity Min. 140 μA/lm
Luminous Sensitivity Typ. 250 μA/lm
Radiant Sensitivity Typ. 74 mA/W
Anode Luminous Sensitivity Min. 400 A/lm
Anode Luminous Sensitivity Typ. 2500 A/lm
Anode Radiant Sensitivity Typ. 7.4e5 A/W
Anode Dark Current (after 30min.) Typ. 3 nA
Anode Dark Current (after 30min.) Max. 50 nA
Time Response Rise Time Typ. 2.2 ns
Time Response Transit Time Typ. 22 ns
1,299.00 1299.0 USD
Price Valid only in North America


A 28mm, side-on type PMT Tube from Hamamatsu.
The effective range is from 185nm to 900nm.
Special feature: extra low dark current, transit time 22ns
input window: 6x8 mm

For full technical specifications, please ask your authorized Sciencetech technical sales staff member.
1,020.00
In Stock
A 28mm, side-on type PMT Tube from Hamamatsu.
The effective range is from 185nm to 900nm.
Special feature: extra low dark current, transit time 22ns
input window: 6x8 mm

For full technical specifications, please ask your authorized Sciencetech technical sales staff member.
1,020.00 1020.0 USD
Price Valid only in North America


A 28mm, side-on type PMT Tube from Hamamatsu.
The effective range is from 185nm to 710nm.

For full technical specifications, please ask your authorized Sciencetech technical sales staff member.
730.00
In Stock
A 28mm, side-on type PMT Tube from Hamamatsu.
The effective range is from 185nm to 710nm.

For full technical specifications, please ask your authorized Sciencetech technical sales staff member.
730.00 730.0 USD
Price Valid only in North America


28 mm (1-1/8 inch) transmission mode S-1 photocathode, Side-on type.
Spectral Response: 400 - 1200nm
Wavelength of Maximum Response: 800nm
Minimum Effective Area (HxW): 16 x 18

Quantum Efficiency (at 25 degrees): 0.04% (Typical)
Anode Dark Current (after 30 min storage in darkness): 350 (typical), 1000 (max) nA
1,946.00
In Stock
28 mm (1-1/8 inch) transmission mode S-1 photocathode, Side-on type.
Spectral Response: 400 - 1200nm
Wavelength of Maximum Response: 800nm
Minimum Effective Area (HxW): 16 x 18

Quantum Efficiency (at 25 degrees): 0.04% (Typical)
Anode Dark Current (after 30 min storage in darkness): 350 (typical), 1000 (max) nA
1,946.00 1946.0 USD
Price Valid only in North America


This product consists of the Sciencetech SOL-METER and our SSIVT-REF sun calibrated reference detector. The SOL-METER is a digital meter for use with solar calibrated detectors such as detector models SSIVT-REF or SC-LT. The meter converts detector measurements to a Sun value. It has a handheld meter that is compact, has a sturdy design, and is appropriate for indoor or outdoor applications.

The Sciencetech Reference Detector, which is an integral part of solar simulator calibration and solar cell I-V characterization, consists of a single element silicon detector and is designed to be used for monitoring and verifying the Sun level of solar simulators. The SSIVT-REF detector is used effective in sensing wavelengths between 190 nm and 1100 nm and is calibrated at Sciencetech against a NIST traceable calibrated reference cell. Comes with a detachable cable with 4 banana plugs for connecting to a measurement device. CE compliant.

Rise time: 0.2 μs
Effective active area: 5.7 sqmm
Dimensions: 50.8 x 50.8 x 25.4 mm
2,800.00
In Stock
This product consists of the Sciencetech SOL-METER and our SSIVT-REF sun calibrated reference detector. The SOL-METER is a digital meter for use with solar calibrated detectors such as detector models SSIVT-REF or SC-LT. The meter converts detector measurements to a Sun value. It has a handheld meter that is compact, has a sturdy design, and is appropriate for indoor or outdoor applications.

The Sciencetech Reference Detector, which is an integral part of solar simulator calibration and solar cell I-V characterization, consists of a single element silicon detector and is designed to be used for monitoring and verifying the Sun level of solar simulators. The SSIVT-REF detector is used effective in sensing wavelengths between 190 nm and 1100 nm and is calibrated at Sciencetech against a NIST traceable calibrated reference cell. Comes with a detachable cable with 4 banana plugs for connecting to a measurement device. CE compliant.

Rise time: 0.2 μs
Effective active area: 5.7 sqmm
Dimensions: 50.8 x 50.8 x 25.4 mm
2,800.00 2800.0 USD
Price Valid only in North America


This is a room-temperature detector for use with the SPS-300. This includes the DTGS detector with a mounting flange, but requires the use of a dual-phase lock-in amplifier (sold separately). Sciencetech's wideband detector design comes packaged in a mounting flange compatible with our SPS-300. It is connectorized to be powered directly from the Stanford SR-810/830 type lock-in amplifiers with a detachable cable. The spectral range is limited by window selection. This detector comes with a HDPE window standard.

Element size: 2.0 mm dia.
Spectral bandwidth: 16 to 100um (for HDPE window, other window materials available)
Frequency response: 10Hz - 265Hz (-3db points)
N.E.P.: 5x10-10 watts (@100Hz)
Power requirements: +/- 15 to +/- 24 volts max @ +/- 8 mA max.
Power connections:
DB-9M
Pins 2,3,4,5,9 no connection
+V In Pin 1
-V In Pin 6
Common Pin 7
Case GND Pin 8
Signal Connection: BNC

Suitable for direct connection to Stanford SR-810/830 lockin preamp power (not included).

This is a room-temperature detector for use with the SPS-300. This includes the DTGS detector with a mounting flange, but requires the use of a dual-phase lock-in amplifier (sold separately).
This is a room-temperature detector for use with the SPS-300. This includes the DTGS detector with a mounting flange, but requires the use of a dual-phase lock-in amplifier (sold separately). Sciencetech's wideband detector design comes packaged in a mounting flange compatible with our SPS-300. It is connectorized to be powered directly from the Stanford SR-810/830 type lock-in amplifiers with a detachable cable. The spectral range is limited by window selection. This detector comes with a HDPE window standard.

Element size: 2.0 mm dia.
Spectral bandwidth: 16 to 100um (for HDPE window, other window materials available)
Frequency response: 10Hz - 265Hz (-3db points)
N.E.P.: 5x10-10 watts (@100Hz)
Power requirements: +/- 15 to +/- 24 volts max @ +/- 8 mA max.
Power connections:
DB-9M
Pins 2,3,4,5,9 no connection
+V In Pin 1
-V In Pin 6
Common Pin 7
Case GND Pin 8
Signal Connection: BNC

Suitable for direct connection to Stanford SR-810/830 lockin preamp power (not included).

This is a room-temperature detector for use with the SPS-300. This includes the DTGS detector with a mounting flange, but requires the use of a dual-phase lock-in amplifier (sold separately).
7,200.00 7200.0 USD
Price Valid only in North America


The Sciencetech SSIVT-REF single element silicon detector is designed to be used for monitoring and verifying the Sun level of solar simulators. The SSIVT-REF detector is used effective in sensing wavelengths between 190 nm and 1100 nm and is calibrated at Sciencetech against a NIST traceable calibrated reference cell. The SSIVT-REF detector can be used with Sciencetech SSIVT measurement system or Sciencetech SOL-METER solar power meter. Comes with a detachable cable with 4 banana plugs for connecting to a measurement device such as a source meter or Sciencetech SOL-METER. CE compliant.

Rise time: 0.2 μs
Effective active area: 5.7 sq. mm
Dimensions: 50.8 × 50.8 × 25.4 mm
625.00
In Stock
The Sciencetech SSIVT-REF single element silicon detector is designed to be used for monitoring and verifying the Sun level of solar simulators. The SSIVT-REF detector is used effective in sensing wavelengths between 190 nm and 1100 nm and is calibrated at Sciencetech against a NIST traceable calibrated reference cell. The SSIVT-REF detector can be used with Sciencetech SSIVT measurement system or Sciencetech SOL-METER solar power meter. Comes with a detachable cable with 4 banana plugs for connecting to a measurement device such as a source meter or Sciencetech SOL-METER. CE compliant.

Rise time: 0.2 μs
Effective active area: 5.7 sq. mm
Dimensions: 50.8 × 50.8 × 25.4 mm
625.00 625.0 USD
Price Valid only in North America


This Broadband Thermopile Detector allows the measurement of total broadband radiation emitted by a light source. It could also be used to measure the light power density on a surface (in W/cm2) which is particularly useful for uniformity measurements and for checking solar simulator performance. This detector has a 19mm diameter sensor and picks up all wavelengths between 190-11μm (UV-VIS-IR). Please note that this detector head requires either an external display controller or computer interface (sold separately - see below) to show the measured power. The price shown includes the detector head, post, post holder, and base only.

This thermopile is recommended for high-powered light sources (such as focused 500W + arc lamps) and concetrator solar simulators (5 Suns +, 500 mW/cm2).
1,418.00
In Stock
This Broadband Thermopile Detector allows the measurement of total broadband radiation emitted by a light source. It could also be used to measure the light power density on a surface (in W/cm2) which is particularly useful for uniformity measurements and for checking solar simulator performance. This detector has a 19mm diameter sensor and picks up all wavelengths between 190-11μm (UV-VIS-IR). Please note that this detector head requires either an external display controller or computer interface (sold separately - see below) to show the measured power. The price shown includes the detector head, post, post holder, and base only.

This thermopile is recommended for high-powered light sources (such as focused 500W + arc lamps) and concetrator solar simulators (5 Suns +, 500 mW/cm2).
1,418.00 1418.0 USD
Price Valid only in North America


Rise/Fall Time: 450ns/45ns
Responsivity: 0.50 A/W
Active Area: Diameter = 9mm
NEP: 5.5E-14 W/Hz^(1/2)@5V
Dark Current: 1.0uA@5V
Material: UV-enhanced Si
Junction Capacitance: 1.75nF @0V
620.00
Rise/Fall Time: 450ns/45ns
Responsivity: 0.50 A/W
Active Area: Diameter = 9mm
NEP: 5.5E-14 W/Hz^(1/2)@5V
Dark Current: 1.0uA@5V
Material: UV-enhanced Si
Junction Capacitance: 1.75nF @0V
620.00 620.0 USD