A Potentiostat is used in with a three electrode cell to perform a myriad of electrochemical experiments, ranging from measuring half-cell potentials, impedance spectroscopy, redox chemistry, and chemical phenomena. These experiments are relevant for corrosion studies, battery chemistry development, materials characterization and more. 

Sciencetech is pleased to represent Zahner in Canada. With 40 years of experience in the field, Zahner’s high-quality electrochemical instruments are backed by years of expertise. Zahner’s systems are an excellent choice for many applications such as corrosion testing, photoelectrochemistry, fuel cell testing, and Li-ion battery testing .

Zahner potentiostats are designed to provide the highest level of performance in electrochemical experiments and have been proven to be precise and versatile devices for any kind of electrochemical application. Zahner potentiostats can be equipped with multiple plug and play add-on cards, which introduce additional analog and digital input/output signals. This modular function makes Zahner's potentiostats very flexible and allows the possibility to customize the potentiostat to suit the needs of its users. 

Zahner Zennium X

Zennium

Electrochemical Workstation


The core of the Zahner instrumentation is an electrochemical workstation. With the Zennium, Zennium E, Zennium-pro, and Zennium-X, there is a workstation available to support the most advanced techniques, as well as a cost-effective option for more straightforward applications. Supported by the Thales software, many different techniques can be accessed from the same software interface, making the Zahner line convenient and easy to use.

With modular components to add on, accessories for your specific technique can be simply and easily added to your workstation, customizing your setup for your specific requirements.

CIMPS Instruments

Photoelectrochemistry


For photoelectrochemistry, the CIMPS instruments are a powerful choice. With a light source included and kept stable by a control loop, considerations such as non-linearity, ageing, and temperature drift no longer need be considered. The package includes the light source (driven by an included slave potentiostat), optical bench, photoelectrochemical cell, and all required software. For QE and IPCE measurements, consider the CIMPS-QE/IPCE package, including all necessary components to collect QE and IPCE measurements from your sample.

The Zahner CIMPS measurement system has been designed with focus on the special demands of dynamic photo-electric investigations like IMPS and IMVS, popular today for instance in alternative solar cell research. Besides all traditional electrochemical investigations supported by THALES - like impedance measurements, cyclic voltammetry, current-potential curves, etc. - now mixed photo electric transfer functions, known as Intensity Modulated Photo Spectra(IMPS/IMVS), can be measured. 

Zahner CIMPS

Electrochemical Workstation Models

Product Comparison

With the following electrochemical workstations available as a base, you can perform many measurements with the workstation alone or choose add-ons to customize your capabilities for your specific requirements:

Contact Us Today
Get more information or request a quote.
X

Product Category

View Filter

x
Clear all x

Filter Option



CIMPS Add-on for Photo-Electrochemical Transmittance/Absorbance
-ILT-960 spectrometer
-PECC-slide with 2 x PECC-2
-LSW-1 LED (420-730 nm) or WOW01 tungsten light source (360-1000 nm)
-CIMPS-abs software

For pricing information, please request a quotation from sales@sciencetech-inc.com.
CIMPS Add-on for Photo-Electrochemical Transmittance/Absorbance
-ILT-960 spectrometer
-PECC-slide with 2 x PECC-2
-LSW-1 LED (420-730 nm) or WOW01 tungsten light source (360-1000 nm)
-CIMPS-abs software

For pricing information, please request a quotation from sales@sciencetech-inc.com.
18,959.00 18959.0 USD
Price Valid only in North America


CIMPS Add-on for Photo-Electrochemical Transmittance/Absorbance
-Backthinned-CCD fiber optic spectrometer
-PECC-slide with 2 x PECC-2 Q
-Balanced tungsten-deuterium light source (220-1100 nm)
-CIMPS-abs software

For pricing information, please request a quotation from sales@sciencetech-inc.com.
CIMPS Add-on for Photo-Electrochemical Transmittance/Absorbance
-Backthinned-CCD fiber optic spectrometer
-PECC-slide with 2 x PECC-2 Q
-Balanced tungsten-deuterium light source (220-1100 nm)
-CIMPS-abs software

For pricing information, please request a quotation from sales@sciencetech-inc.com.
23,594.00 23594.0 USD
Price Valid only in North America


The battery cycling multiplexer BC-MUX is the link between the high power performances of your battery cycler and the EIS precision of our ZENNIUM potentiostats. The BC-MUX can address up to 16 channels to sequentially perform EIS measurements on the connected samples.

Switchboxes which serve as ports between the BC-MUX and the cycler are available as 16 A, 60 A, 150 A or custom made options.

-Sequential measurements on up to 16 channels
-Non-selected channels are connected to the battery cycler

For pricing information, please request a quotation from sales@sciencetech-inc.com.
The battery cycling multiplexer BC-MUX is the link between the high power performances of your battery cycler and the EIS precision of our ZENNIUM potentiostats. The BC-MUX can address up to 16 channels to sequentially perform EIS measurements on the connected samples.

Switchboxes which serve as ports between the BC-MUX and the cycler are available as 16 A, 60 A, 150 A or custom made options.

-Sequential measurements on up to 16 channels
-Non-selected channels are connected to the battery cycler

For pricing information, please request a quotation from sales@sciencetech-inc.com.
5,191.00 5191.0 USD
Price Valid only in North America


Processor Upgrade for IM6 series
-ColdFire CPU board with USB-interface
-Slot covers, USB cable
-HD removal & backup (if possible)
-Factory calibration
-ThalesXT software
-System is controlled by a Windows7/8/10-PC (not included)

For pricing information, please request a quotation from sales@sciencetech-inc.com.
Processor Upgrade for IM6 series
-ColdFire CPU board with USB-interface
-Slot covers, USB cable
-HD removal & backup (if possible)
-Factory calibration
-ThalesXT software
-System is controlled by a Windows7/8/10-PC (not included)

For pricing information, please request a quotation from sales@sciencetech-inc.com.
4,824.00 4824.0 USD
Price Valid only in North America


Light Exclusion Box / Faradays Cage
-Fitting for CIMPS optical rail
-For all CIMPS light sources incl. TLS03 (not for Solar Simulators)
-Easy handling by hinged top/sides and three cable inlets
-Ground connector for shielding (Faradays Cage function)
-Dimensions: 60 x 33 x 23 cm (W x D x H) without handle

For pricing information, please request a quotation from sales@sciencetech-inc.com.
Light Exclusion Box / Faradays Cage
-Fitting for CIMPS optical rail
-For all CIMPS light sources incl. TLS03 (not for Solar Simulators)
-Easy handling by hinged top/sides and three cable inlets
-Ground connector for shielding (Faradays Cage function)
-Dimensions: 60 x 33 x 23 cm (W x D x H) without handle

For pricing information, please request a quotation from sales@sciencetech-inc.com.
2,948.00 2948.0 USD
Price Valid only in North America


Zahner's CIMPS is a highly dynamic LED-based system with an active light feedback loop that ensures a controlled and constant light intensity during the photoelectrochemical or photovoltaic measurements. Fast light sources enable dynamic photoelectrochemical measurements like IMPS/IMVS. The robust control of light intensity allows accurate IMPS/IMVS measurements, giving the system its iconic name ""controlled intensity-modulated photo spectroscopy (CIMPS)"". Further information on our light feedback loop and its benefits is provided in the manuscript ""C in CIMPS"".

CIMPS-pro Photo-Electrochemical Workstation
-Zennium pro workstation
-Frequency range: 10 µHz to 8 MHz
-Max. current: ± 3 A
-Controlled voltage: ± 15 V / ± 5 V
-Compliance voltage: ± 28 V
-HDP technology for outstanding dynamic accuracy
-ADF technology for high-precision high-speed CV (option)
-Floating & grounded mode switchable
-5 slots for additional hardware modules
-EPC42 extension card for controlling PP212
-LED potentiostat: PP212
-Current range: ± 10 A
-Voltage range: ± 20 V
-Frequency range: DC - 200 kHz
-LDA2 Light source setup
-Optical bench
-Calibrated feedback sensor
-LSW-1 plug-in LED
-CIMPS aligner bar
-ThalesXT software package
-TestBox, SIMPECC, CIMPS cable set, calibration data
-System is controlled by a Windows8/10-PC (not included)

For pricing information, please request a quotation from sales@sciencetech-inc.com.
Zahner's CIMPS is a highly dynamic LED-based system with an active light feedback loop that ensures a controlled and constant light intensity during the photoelectrochemical or photovoltaic measurements. Fast light sources enable dynamic photoelectrochemical measurements like IMPS/IMVS. The robust control of light intensity allows accurate IMPS/IMVS measurements, giving the system its iconic name ""controlled intensity-modulated photo spectroscopy (CIMPS)"". Further information on our light feedback loop and its benefits is provided in the manuscript ""C in CIMPS"".

CIMPS-pro Photo-Electrochemical Workstation
-Zennium pro workstation
-Frequency range: 10 µHz to 8 MHz
-Max. current: ± 3 A
-Controlled voltage: ± 15 V / ± 5 V
-Compliance voltage: ± 28 V
-HDP technology for outstanding dynamic accuracy
-ADF technology for high-precision high-speed CV (option)
-Floating & grounded mode switchable
-5 slots for additional hardware modules
-EPC42 extension card for controlling PP212
-LED potentiostat: PP212
-Current range: ± 10 A
-Voltage range: ± 20 V
-Frequency range: DC - 200 kHz
-LDA2 Light source setup
-Optical bench
-Calibrated feedback sensor
-LSW-1 plug-in LED
-CIMPS aligner bar
-ThalesXT software package
-TestBox, SIMPECC, CIMPS cable set, calibration data
-System is controlled by a Windows8/10-PC (not included)

For pricing information, please request a quotation from sales@sciencetech-inc.com.
31,717.00 31717.0 USD
Price Valid only in North America


CIMPS-QE/IPCE is an extended CIMPS system with the capability to measure quantum efficiency (QE) or incident photon to current efficiency (IPCE). The CIMPS-QE/IPCE extension consists of an easily mountable and portable tuneable light source (TLS). The TLS contains dynamic LEDs, a monochromator and a feedback control which allow accurate light illumination during the measurements without any warm up time.

Multiple LEDs in the TLS provide higher light intensity across the broad wavelength range and longer operational lifetime as compared to any traditional Xe-lamp. This high light intensity is crucial for IPCE measurements on DSSC, perovskites or organic solar cells or photoelectrodes.

Like the modular LEDs used in the CIMPS system, the TLS is also able to carry out sine-wave modulation for IPCE measurements and does not require a mechanical chopper. During IPCE measurements, a special indicator is also provided which indicates if the measurement parameters are optimum for IPCE measurement or not. Further information about IPCE measurement is provided in our application note CIMPS-IPCE.

Fully Integrated QE/IPCE Photo-Electrochemical Workstation
-Zennium pro workstation
-Frequency range: 10 µHz to 8 MHz
-Max. current: ± 3 A
-Controlled voltage: ± 15 V / ± 5 V
-Compliance voltage: ± 28 V
-HDP technology for outstanding dynamic accuracy
-ADF technology for high-precision/ high-speed CV (option)
-Floating & grounded mode switchable
-5 slots for additional hardware modules
-EPC42 extension card for controlling PP212
-LED potentiostat: PP212
-Current range: ± 10 A
-Voltage range: ± 20 V
-Frequency range: DC - 200 kHz
-LDA2 Light source setup
-Optical bench
-Calibrated feedback sensor
-LSW-1 plug-in LED
-CIMPS aligner bar
-Tunable light source TLS03
-Wavelength range: 365-1020 nm
-typ. res.: 1 nm@430-720 nm, 15 nm@365-420 nm, 40 nm@735-1020 nm
-typ. line width: 10 nm@365-720 nm, 50 nm@735-1020 nm
-Calibration for 1 mm distance
-Calibration for PECC-2 required, optional
-ThalesXT software package
-TestBox, SIMPECC, CIMPS cable set, calibration data
-System is controlled by a Windows8/10-PC (not included)

For pricing information, please request a quotation from sales@sciencetech-inc.com.
CIMPS-QE/IPCE is an extended CIMPS system with the capability to measure quantum efficiency (QE) or incident photon to current efficiency (IPCE). The CIMPS-QE/IPCE extension consists of an easily mountable and portable tuneable light source (TLS). The TLS contains dynamic LEDs, a monochromator and a feedback control which allow accurate light illumination during the measurements without any warm up time.

Multiple LEDs in the TLS provide higher light intensity across the broad wavelength range and longer operational lifetime as compared to any traditional Xe-lamp. This high light intensity is crucial for IPCE measurements on DSSC, perovskites or organic solar cells or photoelectrodes.

Like the modular LEDs used in the CIMPS system, the TLS is also able to carry out sine-wave modulation for IPCE measurements and does not require a mechanical chopper. During IPCE measurements, a special indicator is also provided which indicates if the measurement parameters are optimum for IPCE measurement or not. Further information about IPCE measurement is provided in our application note CIMPS-IPCE.

Fully Integrated QE/IPCE Photo-Electrochemical Workstation
-Zennium pro workstation
-Frequency range: 10 µHz to 8 MHz
-Max. current: ± 3 A
-Controlled voltage: ± 15 V / ± 5 V
-Compliance voltage: ± 28 V
-HDP technology for outstanding dynamic accuracy
-ADF technology for high-precision/ high-speed CV (option)
-Floating & grounded mode switchable
-5 slots for additional hardware modules
-EPC42 extension card for controlling PP212
-LED potentiostat: PP212
-Current range: ± 10 A
-Voltage range: ± 20 V
-Frequency range: DC - 200 kHz
-LDA2 Light source setup
-Optical bench
-Calibrated feedback sensor
-LSW-1 plug-in LED
-CIMPS aligner bar
-Tunable light source TLS03
-Wavelength range: 365-1020 nm
-typ. res.: 1 nm@430-720 nm, 15 nm@365-420 nm, 40 nm@735-1020 nm
-typ. line width: 10 nm@365-720 nm, 50 nm@735-1020 nm
-Calibration for 1 mm distance
-Calibration for PECC-2 required, optional
-ThalesXT software package
-TestBox, SIMPECC, CIMPS cable set, calibration data
-System is controlled by a Windows8/10-PC (not included)

For pricing information, please request a quotation from sales@sciencetech-inc.com.
52,393.00 52393.0 USD
Price Valid only in North America


CIMPS-QE/IPCE is an extended CIMPS system with the capability to measure quantum efficiency (QE) or incident photon to current efficiency (IPCE). The CIMPS-QE/IPCE extension consists of an easily mountable and portable tuneable light source (TLS). The TLS contains dynamic LEDs, a monochromator and a feedback control which allow accurate light illumination during the measurements without any warm up time.

Multiple LEDs in the TLS provide higher light intensity across the broad wavelength range and longer operational lifetime as compared to any traditional Xe-lamp. This high light intensity is crucial for IPCE measurements on DSSC, perovskites or organic solar cells or photoelectrodes.

Like the modular LEDs used in the CIMPS system, the TLS is also able to carry out sine-wave modulation for IPCE measurements and does not require a mechanical chopper. During IPCE measurements, a special indicator is also provided which indicates if the measurement parameters are optimum for IPCE measurement or not. Further information about IPCE measurement is provided in our application note CIMPS-IPCE.

Fully Integrated QE/IPCE Photo-Electrochemical Workstation with UV
Extension
-Zennium pro workstation
-Frequency range: 10 µHz to 8 MHz
-Max. current: ± 3 A
-Controlled voltage: ± 15 V / ± 5 V
-Compliance voltage: ± 28 V
-HDP technology for outstanding dynamic accuracy
-ADF technology for high-precision/high-speed CV (option)
-Floating & grounded mode switchable
-5 slots for additional hardware modules
-EPC42 extension card for controlling PP212
-LED potentiostat: PP212
-Current range: ± 10 A
-Voltage range: ± 20 V
-Frequency range: DC - 200 kHz
-LDA2 Light source setup
-Optical bench
-Calibrated feedback sensor
-LSW-1 plug-in LED
-CIMPS aligner bar
-Tunable light source TLS03 UV
-Wavelength range: 295-1020 nm
-typ. res.: 1 nm@430-720 nm, 15 nm@295-420 nm, 40 nm@735-1020 nm
-typ. line width: 10 nm@295-720 nm, 50 nm@735-1020 nm
-Calibration for 1 mm distance
-Calibration for PECC-2 q required, optional
-ThalesXT software package
-TestBox, SIMPECC, CIMPS cable set, calibration data
-System is controlled by a Windows8/10-PC (not included)

For pricing information, please request a quotation from sales@sciencetech-inc.com.
CIMPS-QE/IPCE is an extended CIMPS system with the capability to measure quantum efficiency (QE) or incident photon to current efficiency (IPCE). The CIMPS-QE/IPCE extension consists of an easily mountable and portable tuneable light source (TLS). The TLS contains dynamic LEDs, a monochromator and a feedback control which allow accurate light illumination during the measurements without any warm up time.

Multiple LEDs in the TLS provide higher light intensity across the broad wavelength range and longer operational lifetime as compared to any traditional Xe-lamp. This high light intensity is crucial for IPCE measurements on DSSC, perovskites or organic solar cells or photoelectrodes.

Like the modular LEDs used in the CIMPS system, the TLS is also able to carry out sine-wave modulation for IPCE measurements and does not require a mechanical chopper. During IPCE measurements, a special indicator is also provided which indicates if the measurement parameters are optimum for IPCE measurement or not. Further information about IPCE measurement is provided in our application note CIMPS-IPCE.

Fully Integrated QE/IPCE Photo-Electrochemical Workstation with UV
Extension
-Zennium pro workstation
-Frequency range: 10 µHz to 8 MHz
-Max. current: ± 3 A
-Controlled voltage: ± 15 V / ± 5 V
-Compliance voltage: ± 28 V
-HDP technology for outstanding dynamic accuracy
-ADF technology for high-precision/high-speed CV (option)
-Floating & grounded mode switchable
-5 slots for additional hardware modules
-EPC42 extension card for controlling PP212
-LED potentiostat: PP212
-Current range: ± 10 A
-Voltage range: ± 20 V
-Frequency range: DC - 200 kHz
-LDA2 Light source setup
-Optical bench
-Calibrated feedback sensor
-LSW-1 plug-in LED
-CIMPS aligner bar
-Tunable light source TLS03 UV
-Wavelength range: 295-1020 nm
-typ. res.: 1 nm@430-720 nm, 15 nm@295-420 nm, 40 nm@735-1020 nm
-typ. line width: 10 nm@295-720 nm, 50 nm@735-1020 nm
-Calibration for 1 mm distance
-Calibration for PECC-2 q required, optional
-ThalesXT software package
-TestBox, SIMPECC, CIMPS cable set, calibration data
-System is controlled by a Windows8/10-PC (not included)

For pricing information, please request a quotation from sales@sciencetech-inc.com.
58,688.00 58688.0 USD
Price Valid only in North America


IM6 (with ColdFire Processor and EPC42 Card only) to CIMPS
-LED potentiostat: PP212
-Current range: ± 10 A
-Voltage range: ± 20 V
-Frequency range: DC - 200 kHz
-LDA2 Light source setup
-Optical bench
-Calibrated feedback sensor
-LSW-1 plug-in LED
-CIMPS aligner bar
-ThalesXT software package
-SIMPECC, CIMPS cable set, calibration data

For pricing information, please request a quotation from sales@sciencetech-inc.com.
IM6 (with ColdFire Processor and EPC42 Card only) to CIMPS
-LED potentiostat: PP212
-Current range: ± 10 A
-Voltage range: ± 20 V
-Frequency range: DC - 200 kHz
-LDA2 Light source setup
-Optical bench
-Calibrated feedback sensor
-LSW-1 plug-in LED
-CIMPS aligner bar
-ThalesXT software package
-SIMPECC, CIMPS cable set, calibration data

For pricing information, please request a quotation from sales@sciencetech-inc.com.
10,751.00 10751.0 USD
Price Valid only in North America


Zennium/X/pro to CIMPS/X/pro
-EPC42 extension card for controlling PP212
-LED potentiostat: PP212
-Current range: ± 10 A
-Voltage range: ± 20 V
-Frequency range: DC - 200 kHz
-LDA2 Light source setup
-Optical bench
-Calibrated feedback sensor
-LSW-1 plug-in LED
-CIMPS aligner bar
-ThalesXT software package
-SIMPECC, CIMPS cable set, calibration data

For pricing information, please request a quotation from sales@sciencetech-inc.com.
Zennium/X/pro to CIMPS/X/pro
-EPC42 extension card for controlling PP212
-LED potentiostat: PP212
-Current range: ± 10 A
-Voltage range: ± 20 V
-Frequency range: DC - 200 kHz
-LDA2 Light source setup
-Optical bench
-Calibrated feedback sensor
-LSW-1 plug-in LED
-CIMPS aligner bar
-ThalesXT software package
-SIMPECC, CIMPS cable set, calibration data

For pricing information, please request a quotation from sales@sciencetech-inc.com.
11,931.00 11931.0 USD
Price Valid only in North America


CIMPS-X Photo-Electrochemical Workstation
-Zennium X workstation
-Frequency range: 10 µHz to 12 MHz
-Max. current: ± 4 A
-Controlled voltage: ± 15 V / ± 5 V
-Compliance voltage: ± 32 V
-HDP technology for outstanding dynamic accuracy
-ADF technology for high-precision high-speed CV
-Floating & grounded mode switchable
-10 slots for additional hardware modules
-EPC42 extension card for controlling PP212
-LED potentiostat: PP212
-Current range: ± 10 A
-Voltage range: ± 20 V
-Frequency range: DC - 200 kHz
-LDA2 Light source setup
-Optical bench
-Calibrated feedback sensor
-LSW-1 plug-in LED
-CIMPS aligner bar
-ThalesXT software package
-TestBox, SIMPECC, CIMPS cable set, calibration data
-System is controlled by a Windows8/10-PC (not included)

For pricing information, please request a quotation from sales@sciencetech-inc.com.
CIMPS-X Photo-Electrochemical Workstation
-Zennium X workstation
-Frequency range: 10 µHz to 12 MHz
-Max. current: ± 4 A
-Controlled voltage: ± 15 V / ± 5 V
-Compliance voltage: ± 32 V
-HDP technology for outstanding dynamic accuracy
-ADF technology for high-precision high-speed CV
-Floating & grounded mode switchable
-10 slots for additional hardware modules
-EPC42 extension card for controlling PP212
-LED potentiostat: PP212
-Current range: ± 10 A
-Voltage range: ± 20 V
-Frequency range: DC - 200 kHz
-LDA2 Light source setup
-Optical bench
-Calibrated feedback sensor
-LSW-1 plug-in LED
-CIMPS aligner bar
-ThalesXT software package
-TestBox, SIMPECC, CIMPS cable set, calibration data
-System is controlled by a Windows8/10-PC (not included)

For pricing information, please request a quotation from sales@sciencetech-inc.com.
41,126.00 41126.0 USD
Price Valid only in North America


Tool-Kit for Coating and Laminate Testing
-Cu-block, steel-electrodes
-Electrolyte carrier and buffer solution
-Cable set
-Electrode stand
-COLT software

For pricing information, please request a quotation from sales@sciencetech-inc.com.
Tool-Kit for Coating and Laminate Testing
-Cu-block, steel-electrodes
-Electrolyte carrier and buffer solution
-Cable set
-Electrode stand
-COLT software

For pricing information, please request a quotation from sales@sciencetech-inc.com.
2,754.00 2754.0 USD
Price Valid only in North America


The EL1002 single-quadrant potentiostat was designed as an extension for the Zennium series to perform measurements on high power electrochemical systems such as PEM or solid oxide fuel cells. This highly dynamic electronic load was optimized for EIS measurements on frequencies on the order of 10 µHz to 100 kHz at high current densities.

The EL1002 is suited for power dissipation up to 1 kW at voltages up to 100 V. It can modulate and control currents of up to 200 A. Due to the innovative connection concept of the EL1002, additional power supplies or electronic loads can extend the current range up to 680 A. The EXT-concept allows for outstanding EIS quality at high currents and conserves a good value to price ratio.

The versatile interconnection capabilities of the EL1002 gives access to measurements at high currents on large-scale batteries, electrolyzers or fuel cells.


-Power extension of ZENNIUM potentiostat for battery, fuel cells, or electrolyzer stack measurements up 68 kW
-Dynamic EIS measurements at high power from 10 µHz bis 100 kHz
-High bandwitdh and outstanding EIS data quality

For pricing information, please request a quotation from sales@sciencetech-inc.com.
The EL1002 single-quadrant potentiostat was designed as an extension for the Zennium series to perform measurements on high power electrochemical systems such as PEM or solid oxide fuel cells. This highly dynamic electronic load was optimized for EIS measurements on frequencies on the order of 10 µHz to 100 kHz at high current densities.

The EL1002 is suited for power dissipation up to 1 kW at voltages up to 100 V. It can modulate and control currents of up to 200 A. Due to the innovative connection concept of the EL1002, additional power supplies or electronic loads can extend the current range up to 680 A. The EXT-concept allows for outstanding EIS quality at high currents and conserves a good value to price ratio.

The versatile interconnection capabilities of the EL1002 gives access to measurements at high currents on large-scale batteries, electrolyzers or fuel cells.


-Power extension of ZENNIUM potentiostat for battery, fuel cells, or electrolyzer stack measurements up 68 kW
-Dynamic EIS measurements at high power from 10 µHz bis 100 kHz
-High bandwitdh and outstanding EIS data quality

For pricing information, please request a quotation from sales@sciencetech-inc.com.
16,256.00 16256.0 USD
Price Valid only in North America


CIMPS Add-on for Photo-Electrochemical Light Emission
-SEL033 NIST traceable sensor
-CIMPS-emit software for integral measurements

For pricing information, please request a quotation from sales@sciencetech-inc.com.
CIMPS Add-on for Photo-Electrochemical Light Emission
-SEL033 NIST traceable sensor
-CIMPS-emit software for integral measurements

For pricing information, please request a quotation from sales@sciencetech-inc.com.
3,608.00 3608.0 USD
Price Valid only in North America


CIMPS Add-on for Photo-Electrochemical Light Emission
-SEL033 NIST traceable sensor
-ILT-960 spectrometer
-Integral & spectrally resolved measurements
-CIMPS-emit software for integral and spectral resolved measurements

For pricing information, please request a quotation from sales@sciencetech-inc.com.
CIMPS Add-on for Photo-Electrochemical Light Emission
-SEL033 NIST traceable sensor
-ILT-960 spectrometer
-Integral & spectrally resolved measurements
-CIMPS-emit software for integral and spectral resolved measurements

For pricing information, please request a quotation from sales@sciencetech-inc.com.
14,897.00 14897.0 USD
Price Valid only in North America


The EPC42 is the link between the ZENNIUM potentiostat and the power and auxiliary potentiostats or electronic loads. One EPC42 card can address up to four PP/EL/XPOT devices sequentially. Up to four EPC42 cards can be installed in a ZENNIUM X and ZENNIUM PRO potentiostat. In total, a ZENNIUM series potentiostat can be simultaneously connected with up to 16 external PPs/ELs, which can be controlled sequentially.

-Control up to 16 external potentiostats and loads

For pricing information, please request a quotation from sales@sciencetech-inc.com.
The EPC42 is the link between the ZENNIUM potentiostat and the power and auxiliary potentiostats or electronic loads. One EPC42 card can address up to four PP/EL/XPOT devices sequentially. Up to four EPC42 cards can be installed in a ZENNIUM X and ZENNIUM PRO potentiostat. In total, a ZENNIUM series potentiostat can be simultaneously connected with up to 16 external PPs/ELs, which can be controlled sequentially.

-Control up to 16 external potentiostats and loads

For pricing information, please request a quotation from sales@sciencetech-inc.com.
1,334.00 1334.0 USD
Price Valid only in North America


The FRA-Probe interfaces a third-party potentiostat or an electronic load to a ZENNIUM series potentiostat. The probe allows ZENNIUM potentiostats to modulate the current or voltage signal of third party potentiostats and carry out EIS measurements. The FRA-Probe allows ZENNIUM users to expand the power range to unlimited scales enabling EIS measurements on extreme samples like full stack fuel cells.

The third party potentiostat or the electronic load must provide an analog control input and analog signal outputs for use with the FRA-Probe.

The FRA-Probe interfaced setup can also be incorporated in a Python lab environment and can be controlled remotely.

For pricing information, please request a quotation from sales@sciencetech-inc.com.
The FRA-Probe interfaces a third-party potentiostat or an electronic load to a ZENNIUM series potentiostat. The probe allows ZENNIUM potentiostats to modulate the current or voltage signal of third party potentiostats and carry out EIS measurements. The FRA-Probe allows ZENNIUM users to expand the power range to unlimited scales enabling EIS measurements on extreme samples like full stack fuel cells.

The third party potentiostat or the electronic load must provide an analog control input and analog signal outputs for use with the FRA-Probe.

The FRA-Probe interfaced setup can also be incorporated in a Python lab environment and can be controlled remotely.

For pricing information, please request a quotation from sales@sciencetech-inc.com.
1,441.00 1441.0 USD
Price Valid only in North America


Upgrade: Cypress to FTDI USB Chip
-Including calibration of workstation

For pricing information, please request a quotation from sales@sciencetech-inc.com.
Upgrade: Cypress to FTDI USB Chip
-Including calibration of workstation

For pricing information, please request a quotation from sales@sciencetech-inc.com.
3,333.00 3333.0 USD
Price Valid only in North America


High Impedance Probe

The HiZ probe set is specially designed for high impedance measurements and raise the input impedance up to 1000 TΩ || 1 pF.

U- and I-probe come in two small boxes which can easily be placed near by the sample. By this, electrical noise artifacts are minimized. Typical applications are investigations on passive layers, oxydes, nitrides, dielectric films, ceramic substrates, low conductive electrolytes, lacquers, coatings, microelectrodes etc.
The HiZ Probe set is connected to the Probe I and the Probe E terminals of the IM6 or Zennium. No additional hardware is needed.

Input impedance: 5 pF//10 T (typ.)

For pricing information, please request a quotation from sales@sciencetech-inc.com.
High Impedance Probe

The HiZ probe set is specially designed for high impedance measurements and raise the input impedance up to 1000 TΩ || 1 pF.

U- and I-probe come in two small boxes which can easily be placed near by the sample. By this, electrical noise artifacts are minimized. Typical applications are investigations on passive layers, oxydes, nitrides, dielectric films, ceramic substrates, low conductive electrolytes, lacquers, coatings, microelectrodes etc.
The HiZ Probe set is connected to the Probe I and the Probe E terminals of the IM6 or Zennium. No additional hardware is needed.

Input impedance: 5 pF//10 T (typ.)

For pricing information, please request a quotation from sales@sciencetech-inc.com.
1,651.00 1651.0 USD
Price Valid only in North America


Corrosion Cell Kit

The corrosion measuring cell KMZ3 is a triple electrode non-water-jacketed cell for standard electrochemical measurements.

The measuring cell has different cell tops with standard taper joints (NS) for the insertion of the working and the counter electrodes, as well as the intermediate vessel with reference electrode and liquid junction tube including a ""Haber Luggin capilary"". All electrodes have glass bodies with standard tapers. The cell features a user-friendly handling and a wide range of applications.

KMZ3 comes with: specimen holder (WE), counter electrode, reference electrode (Calomel), liquid junction tube, intermediate vessel, gas in- and outlet.

Glass vessel
3-electrode configuration
Pt counter electrode
Ag/AgCl reference electrode
Sample holder

For pricing information, please request a quotation from sales@sciencetech-inc.com.
Corrosion Cell Kit

The corrosion measuring cell KMZ3 is a triple electrode non-water-jacketed cell for standard electrochemical measurements.

The measuring cell has different cell tops with standard taper joints (NS) for the insertion of the working and the counter electrodes, as well as the intermediate vessel with reference electrode and liquid junction tube including a ""Haber Luggin capilary"". All electrodes have glass bodies with standard tapers. The cell features a user-friendly handling and a wide range of applications.

KMZ3 comes with: specimen holder (WE), counter electrode, reference electrode (Calomel), liquid junction tube, intermediate vessel, gas in- and outlet.

Glass vessel
3-electrode configuration
Pt counter electrode
Ag/AgCl reference electrode
Sample holder

For pricing information, please request a quotation from sales@sciencetech-inc.com.
2,548.00 2548.0 USD
Price Valid only in North America