Other Accessories | Sciencetech Inc.

Other Accessories

X

Product Category

View Filter

x
Clear all x

Filter Option



Sciencetech's [160-REC] is a cooling water recirculator. It is designed to work with any of Sciencetech's liquid cooled solar cell chucks. This recirculator can maintain your sample at room temperature while sinking up to 900W of power from your light source.

-Dissipates up to 900W of thermal heat
-External fan cooled radiator system
-Cools to ambient temperature
-Real time sample temperature display (in °C or °F)
-Adjustable cooling rate
2,016.00
In stock
Sciencetech's [160-REC] is a cooling water recirculator. It is designed to work with any of Sciencetech's liquid cooled solar cell chucks. This recirculator can maintain your sample at room temperature while sinking up to 900W of power from your light source.

-Dissipates up to 900W of thermal heat
-External fan cooled radiator system
-Cools to ambient temperature
-Real time sample temperature display (in °C or °F)
-Adjustable cooling rate
2,016.00 2016.0 USD
Price Valid only in North America


Sciencetech's Model [210-REC] is a Cooling Water Recirculator. It sink up to 2500W of heat.

-Dissipates up to 2500W of thermal heat
-External fan cooled radiator system
-Cools to ambient temperature
-Real time sample temperature display (in °C or °F)
-Adjustable cooling rate

Sciencetech's Model [210-REC] is a Cooling Water Recirculator. It sink up to 2500W of heat.

-Dissipates up to 2500W of thermal heat
-External fan cooled radiator system
-Cools to ambient temperature
-Real time sample temperature display (in °C or °F)
-Adjustable cooling rate

2,200.00 2200.0 USD
Price Valid only in North America


This Broadband Thermopile Detector allows the measurement of infrared light in the 0.19 – 20 µm range. This detector has a 12mm diameter sensor, measures up to 3 W (0.5 uW NEP). Please note that this detector head requires either an external display controller or computer interface (such as the UNO-1, sold separately) to show the measured power. The price shown includes the detector head, post, post holder, and base only.

This thermopile is recommended for smaller light sources (collimated 500W arc lamps and below) and standard solar simulators (<5 Suns, <500 mW/cm2).
1,727.00
In stock
This Broadband Thermopile Detector allows the measurement of infrared light in the 0.19 – 20 µm range. This detector has a 12mm diameter sensor, measures up to 3 W (0.5 uW NEP). Please note that this detector head requires either an external display controller or computer interface (such as the UNO-1, sold separately) to show the measured power. The price shown includes the detector head, post, post holder, and base only.

This thermopile is recommended for smaller light sources (collimated 500W arc lamps and below) and standard solar simulators (<5 Suns, <500 mW/cm2).
1,727.00 1727.0 USD
Price Valid only in North America


4kW max average power, 100mm aperture, water-cooled. Doesn't require monitor, includes USB cable and PC-HP application software.

Sensitivity 0.4 mW/W,
rise time 7 sec,
spectral range 0.19-20um.
7,911.00
In stock
4kW max average power, 100mm aperture, water-cooled. Doesn't require monitor, includes USB cable and PC-HP application software.

Sensitivity 0.4 mW/W,
rise time 7 sec,
spectral range 0.19-20um.
7,911.00 7911.0 USD
Price Valid only in North America


The SCI-SCC6-B cell chuck is an economical way of providing electrical connection to the back of your test cells. It is compatible with all of Sciencetech's probe systems except the SCP-MP-T and SCP-MP-G. It is not capable of vacuum hold down.
Working Area: 6" x 6"
Temperature Range: N/A
Power Input: N/A
Power Usage: N/A
Options: N/A
898.00
In stock
The SCI-SCC6-B cell chuck is an economical way of providing electrical connection to the back of your test cells. It is compatible with all of Sciencetech's probe systems except the SCP-MP-T and SCP-MP-G. It is not capable of vacuum hold down.
Working Area: 6" x 6"
Temperature Range: N/A
Power Input: N/A
Power Usage: N/A
Options: N/A
898.00 898.0 USD
Price Valid only in North America


Cooling capacity: 800W (2730BTU/hr) @ 25°C liquid/ambient
Temperature options: liquid set-point (1 to 50°C), optional external thermocouple set-point (1 to 149°C), liquid and ambient delta-T (± -50 to 50°C), external sensor and ambient delta-T (± -50 to 50°C).
Select only values you want displayed on the front 2-line OLED display (fixed or rotating)
Adjust pump speed with 10 level increments
Show pump impeller speed in RPM
Show coolant flow rate in LPM/GPM
Show condenser fan speed in RPM
Adjust audio alarm based on temperatures
Relay trigger can be configured as NO or NC and adjusted based on temperatures
Refrigerant: R-134a
Power input: 120VAC, 60Hz
Maximum power consumption @ ambient (approximate): 450W @ 25°C, 650W @ 35°C
Designed for an operational temperature range of 0-40°C (ambient and liquid)
Reservoir capacity: 3 liters
G 1/4 BSPP threads on back for fittings
NOTE: Requires 120VAC, 60Hz input power. Keep unit upright at all times, and for at least 24 hours before applying power to ensure sufficient oil reaches the compressor.


Weight 57.00 lb (25.86 kg)
Max Pressure @ 25°C 2kgf/cm2 (28.5psi)
Max Temperature 40°C (104°F)
2,520.00
In stock
Cooling capacity: 800W (2730BTU/hr) @ 25°C liquid/ambient
Temperature options: liquid set-point (1 to 50°C), optional external thermocouple set-point (1 to 149°C), liquid and ambient delta-T (± -50 to 50°C), external sensor and ambient delta-T (± -50 to 50°C).
Select only values you want displayed on the front 2-line OLED display (fixed or rotating)
Adjust pump speed with 10 level increments
Show pump impeller speed in RPM
Show coolant flow rate in LPM/GPM
Show condenser fan speed in RPM
Adjust audio alarm based on temperatures
Relay trigger can be configured as NO or NC and adjusted based on temperatures
Refrigerant: R-134a
Power input: 120VAC, 60Hz
Maximum power consumption @ ambient (approximate): 450W @ 25°C, 650W @ 35°C
Designed for an operational temperature range of 0-40°C (ambient and liquid)
Reservoir capacity: 3 liters
G 1/4 BSPP threads on back for fittings
NOTE: Requires 120VAC, 60Hz input power. Keep unit upright at all times, and for at least 24 hours before applying power to ensure sufficient oil reaches the compressor.


Weight 57.00 lb (25.86 kg)
Max Pressure @ 25°C 2kgf/cm2 (28.5psi)
Max Temperature 40°C (104°F)
2,520.00 2520.0 USD
Price Valid only in North America


Target size: 100x100mm
DAQ: 16 bit
Detector size : 20x20mm (apertured to 12.5x12.5mm)
Detector Type: SCI-REF-LR
Connectivity: 1 x USB2.0
Power Requirements: 120VAC x 4A / 220VAC x 2A
Dimensions: 200x200x125
4,325.00
In stock
Target size: 100x100mm
DAQ: 16 bit
Detector size : 20x20mm (apertured to 12.5x12.5mm)
Detector Type: SCI-REF-LR
Connectivity: 1 x USB2.0
Power Requirements: 120VAC x 4A / 220VAC x 2A
Dimensions: 200x200x125
4,325.00 4325.0 USD
Price Valid only in North America


Target size: 350x350mm
DAQ: 16 bit
Detector size : 20x20mm
Detector Type: SCI-REF-LR
Connectivity: 1 x USB2.0
Power Requirements: 120VAC x 4A / 220VAC x 2A
Dimensions: 600x600x125

Includes SciMeasurementStage software
6,485.00
In stock
Target size: 350x350mm
DAQ: 16 bit
Detector size : 20x20mm
Detector Type: SCI-REF-LR
Connectivity: 1 x USB2.0
Power Requirements: 120VAC x 4A / 220VAC x 2A
Dimensions: 600x600x125

Includes SciMeasurementStage software
6,485.00 6485.0 USD
Price Valid only in North America


Target size: 500x500mm
DAQ: 16 bit
Detector size : 20x20mm
Detector Type: SCI-REF-LR
Connectivity: 1 x USB2.0
Power Requirements: 120VAC x 4A / 220VAC x 2A
Dimensions: 800x800x125
7,475.00
In stock
Target size: 500x500mm
DAQ: 16 bit
Detector size : 20x20mm
Detector Type: SCI-REF-LR
Connectivity: 1 x USB2.0
Power Requirements: 120VAC x 4A / 220VAC x 2A
Dimensions: 800x800x125
7,475.00 7475.0 USD
Price Valid only in North America
Copyright © Sciencetech