Products | Sciencetech Inc.
Sciencetech has a large selection of "stand alone" and "open architecture" off-the-shelf and custom made products for researchers using spectroscopy or working with photovoltaics. We offer technical staff to help with the development of custom systems for special applications. Since 1985, Sciencetech has manufactured Modular Instrumentation for Spectroscopy, TeraHertz FTIRs, Highly Collimated Large Solar Simulators, Flash and Continuous Solar Simulators, Photovoltaic Instrumentation, Quantum Efficiency and Spectral Response Systems, Spectrophotometers/radiometers, Monochromators, Detection Systems, and Light Sources to offer to the global research community through a network of representatives.

 here

Sciencetech product design

SCIENCETECH has built a reputation on custom solutions. Whether you need a small modification to an existing system or a completely novel design built from the ground up to meet your technical specifications, Sciencetech's engineering and optical design teams are ready to help.

SCIENCETECH prides itself on our ability to build custom solutions and systems to the most exacting of specifications. Whether you need higher sensitivity, better throughput, more power, better spectral matching, higher resolution, or any other variable modified to give you exactly what you need, our team of engineers, physicists, and optical designers stand ready to provide you with a solution that will meet your technical requirements.

SCIENCETECH'S SOLAR SIMULATORS IN ACTION - The European Commission just released an article involving the use of Sciencetech's solar simulators in their new facility. Read the full article HERE.

X

Product Category

View Filter

x
Clear all x

Filter Option



1600 W Collimated Research Grade Arc Lamp Source. Utilizes a 2 lens F/1 fused silica lens assembly to collimate the light from the high intensity Xenon arc lamp. Includes 611 series touch screen computer controllable power supply, 1 lamp and digital copies of instrument test report, operating instructions and software.

Power Requirements
200-240 VAC input, 12.1-9.0A, 50/60Hz, Fused 15A
Includes 1 IEC 60320 C19 compatible power cable, select compatible cable for your region.
13,000.00
1600 W Collimated Research Grade Arc Lamp Source. Utilizes a 2 lens F/1 fused silica lens assembly to collimate the light from the high intensity Xenon arc lamp. Includes 611 series touch screen computer controllable power supply, 1 lamp and digital copies of instrument test report, operating instructions and software.

Power Requirements
200-240 VAC input, 12.1-9.0A, 50/60Hz, Fused 15A
Includes 1 IEC 60320 C19 compatible power cable, select compatible cable for your region.
13,000.00 13000.0 USD
Price Valid only in North America


CIMPS add-on for dynamic transmittance/reflectance measurements
-PAD4 card for parallel acquisition of up to 4 sensors
-4 calibrated sensor: 1x UV, 1x NIR, 2xVIS with filter catalogue
-White light source
-CIMPS-dtr/ois software

For pricing information, please request a quotation from sales@sciencetech-inc.com.
CIMPS add-on for dynamic transmittance/reflectance measurements
-PAD4 card for parallel acquisition of up to 4 sensors
-4 calibrated sensor: 1x UV, 1x NIR, 2xVIS with filter catalogue
-White light source
-CIMPS-dtr/ois software

For pricing information, please request a quotation from sales@sciencetech-inc.com.
12,654.00 12654.0 USD
Price Valid only in North America


1000W Focused Beam Research Grade Arc Lamp Source. Utilizes a 3 lens fused silica lens assembly to produce an F/3 focussed image of the high intensity Xenon arc lamp. Includes 611 series touch screen computer controllable power supply, 1 lamp and digital copies of instrument test report, operating instructions and software.
12,500.00
1000W Focused Beam Research Grade Arc Lamp Source. Utilizes a 3 lens fused silica lens assembly to produce an F/3 focussed image of the high intensity Xenon arc lamp. Includes 611 series touch screen computer controllable power supply, 1 lamp and digital copies of instrument test report, operating instructions and software.
12,500.00 12500.0 USD
Price Valid only in North America


500 W Focused Beam Research Grade Arc Lamp Source. Utilizes a 3 lens fused silica lens assembly to produce an F/3 focussed image of the high intensity Xenon arc lamp. Includes 611 series touch screen computer controllable power supply, 1 lamp and digital copies of instrument test report, operating instructions and softare.
12,500.00
500 W Focused Beam Research Grade Arc Lamp Source. Utilizes a 3 lens fused silica lens assembly to produce an F/3 focussed image of the high intensity Xenon arc lamp. Includes 611 series touch screen computer controllable power supply, 1 lamp and digital copies of instrument test report, operating instructions and softare.
12,500.00 12500.0 USD
Price Valid only in North America


1000 W Collimated Research Grade Arc Lamp Source. Utilizes a 2 lens F/1 fused silica lens assembly to collimate the light from the high intensity Xenon arc lamp. Includes 611 series touch screen computer controllable power supply, 1 lamp and digital copies of instrument test report, operating instructions and softare.

Power Requirements
200-240 VAC input, 12.1-9.0A, 50/60Hz, Fused 15A
Includes 1 IEC 60320 C19 compatible power cable, select compatible cable for your region.
12,000.00
1000 W Collimated Research Grade Arc Lamp Source. Utilizes a 2 lens F/1 fused silica lens assembly to collimate the light from the high intensity Xenon arc lamp. Includes 611 series touch screen computer controllable power supply, 1 lamp and digital copies of instrument test report, operating instructions and softare.

Power Requirements
200-240 VAC input, 12.1-9.0A, 50/60Hz, Fused 15A
Includes 1 IEC 60320 C19 compatible power cable, select compatible cable for your region.
12,000.00 12000.0 USD
Price Valid only in North America


500 W Collimated Research Grade Arc Lamp Source. Utilizes a 2 lens F/1 fused silica lens assembly to collimate the light from the high intensity Xenon arc lamp. Includes 611 series touch screen computer controllable power supply, 1 lamp and digital copies of instrument test report, operating instructions and softare.
12,000.00
500 W Collimated Research Grade Arc Lamp Source. Utilizes a 2 lens F/1 fused silica lens assembly to collimate the light from the high intensity Xenon arc lamp. Includes 611 series touch screen computer controllable power supply, 1 lamp and digital copies of instrument test report, operating instructions and softare.
12,000.00 12000.0 USD
Price Valid only in North America


Zennium/X/pro to CIMPS/X/pro
-EPC42 extension card for controlling PP212
-LED potentiostat: PP212
-Current range: ± 10 A
-Voltage range: ± 20 V
-Frequency range: DC - 200 kHz
-LDA2 Light source setup
-Optical bench
-Calibrated feedback sensor
-LSW-1 plug-in LED
-CIMPS aligner bar
-ThalesXT software package
-SIMPECC, CIMPS cable set, calibration data

For pricing information, please request a quotation from sales@sciencetech-inc.com.
Zennium/X/pro to CIMPS/X/pro
-EPC42 extension card for controlling PP212
-LED potentiostat: PP212
-Current range: ± 10 A
-Voltage range: ± 20 V
-Frequency range: DC - 200 kHz
-LDA2 Light source setup
-Optical bench
-Calibrated feedback sensor
-LSW-1 plug-in LED
-CIMPS aligner bar
-ThalesXT software package
-SIMPECC, CIMPS cable set, calibration data

For pricing information, please request a quotation from sales@sciencetech-inc.com.
11,931.00 11931.0 USD
Price Valid only in North America


The SSIVT is a complete electrical current-voltage (I-V) measurement system used to characterize photovoltaic cell performance. This current-voltage tester works by sampling current at different voltages of the photovoltaic cell with a variable impedance load. The system can generate I-V curve of samples like Solar cells.

This I-V Measurement System has a 4 wire Kelvin configuration to remove the resistance effects of the leads and bias the cell at specific voltages.

The I-V Measurement System SSIVT-20F includes:

A) Keithley SMU, Model 2400
- Power: 20W
- Max V: 200V
- Max I: 1A

B) Sciencetech’s SciPV: IV Software for Windows-based control.
- Windows 7/10 32/64bit

C) RS232 to USB dongle

Additional monitoring electronics are provided flash IV measurement

The SSIVT-20F works with all Sciencetech Flash Solar Simulators.


11,625.00
In stock
The SSIVT is a complete electrical current-voltage (I-V) measurement system used to characterize photovoltaic cell performance. This current-voltage tester works by sampling current at different voltages of the photovoltaic cell with a variable impedance load. The system can generate I-V curve of samples like Solar cells.

This I-V Measurement System has a 4 wire Kelvin configuration to remove the resistance effects of the leads and bias the cell at specific voltages.

The I-V Measurement System SSIVT-20F includes:

A) Keithley SMU, Model 2400
- Power: 20W
- Max V: 200V
- Max I: 1A

B) Sciencetech’s SciPV: IV Software for Windows-based control.
- Windows 7/10 32/64bit

C) RS232 to USB dongle

Additional monitoring electronics are provided flash IV measurement

The SSIVT-20F works with all Sciencetech Flash Solar Simulators.


11,625.00 11625.0 USD
Price Valid only in North America


The TEO-402 is a compact Michelson interferometer module with built-in laser and a broadband IR source. It is designed to be used as a core component in a complete FTIR instrument.
Note that this system does not include a power supply, AD board, or detector.
11,288.00
In stock
The TEO-402 is a compact Michelson interferometer module with built-in laser and a broadband IR source. It is designed to be used as a core component in a complete FTIR instrument.
Note that this system does not include a power supply, AD board, or detector.
11,288.00 11288.0 USD
Price Valid only in North America


Sciencetech's XE-LUM Luminaire is a low cost solution for researchers requiring large areas of illumination with good spectral matching but do not require high levels of spatial uniformity. The XE-LUM includes a 1.6kW Xenon arc lamp and efficient collection reflectors. At a working distance of 50cm an irradiance of 1 sun AM1.5G sun level can be achieved with an illumination area of 50x50cm. The area of illumination is up to 1.0m x 1.0m with a working distance of 1 meter.
The XE-LUM can achieve better uniformity when paired with multiple units in an array to flood the illumination plane.

The stand is an accessory that is sold separately. The XE-LUM can be arranged for vertical or horizontal illumination. In either configuration, the Luminaire can be rotated through 360 degrees in both sagittal and tangential planes.

200 to 240 VAC, 12.1 to 9.0 A.
Requires 1 IEC 60320 C19 power cord


Please speak with your authorized Sciencetech technical sales staff member for larger illumination areas, different spectral matches, or to have other customized options for this system.
11,220.00
In stock
Sciencetech's XE-LUM Luminaire is a low cost solution for researchers requiring large areas of illumination with good spectral matching but do not require high levels of spatial uniformity. The XE-LUM includes a 1.6kW Xenon arc lamp and efficient collection reflectors. At a working distance of 50cm an irradiance of 1 sun AM1.5G sun level can be achieved with an illumination area of 50x50cm. The area of illumination is up to 1.0m x 1.0m with a working distance of 1 meter.
The XE-LUM can achieve better uniformity when paired with multiple units in an array to flood the illumination plane.

The stand is an accessory that is sold separately. The XE-LUM can be arranged for vertical or horizontal illumination. In either configuration, the Luminaire can be rotated through 360 degrees in both sagittal and tangential planes.

200 to 240 VAC, 12.1 to 9.0 A.
Requires 1 IEC 60320 C19 power cord


Please speak with your authorized Sciencetech technical sales staff member for larger illumination areas, different spectral matches, or to have other customized options for this system.
11,220.00 11220.0 USD
Price Valid only in North America


This option allows the SPS-300 to use both output ports simultaneously. The internal mirror that directs the parallel beam to the converging output is replaced by a large beam splitter which sends half the radiation to the converging output, and the other half to the parallel output.

Please discuss any questions you have regarding the beam splitter, or operating two detectors simultaneously, with your authorized Sciencetech technical sales staff.
This option allows the SPS-300 to use both output ports simultaneously. The internal mirror that directs the parallel beam to the converging output is replaced by a large beam splitter which sends half the radiation to the converging output, and the other half to the parallel output.

Please discuss any questions you have regarding the beam splitter, or operating two detectors simultaneously, with your authorized Sciencetech technical sales staff.
11,176.00 11176.0 USD
Price Valid only in North America


This is a microscope accessory that allows a point on the microscope field of view to be singled out for intensity or spectroscopy measurement while the light from the other areas in the field of view are physically blocked out.
A proprietary 4 curtain mechanism allows the user to crop any rectangular region of any size and any aspect ratio in the field of view to be measured while the remaining regions are blocked out. The cropped field of view can be seen through an observation eye piece. A filter drawer allows the use of color glass or interferometric filters for the rejection of undesired wavelengths.
Light transmitted through the cropped region is then directed to an output port where its intensity can be measured by an optional detector or broken down further into its constituent wavelengths via an optional monochromator attachment.
The system is light tight allowing for the use of a photon counting detector. A second output port is also available as an option for dual simultaneous measurements with a dichroic mirror or flipping mirror separating the two ports.

Technical Specifications
Filter Drawer: Accepts 1" diameter or square filters
Output Signal: 0 to 13 V
Output Connection: BNC connector
Usage: With DVM or A/D to computer
Modes: Analog or photon counting
Analytical Area Selector: 4 blade independent slit (or optional iris)
Dimensions: 266.7 x 63.5 x 279.4mm
11,027.00
In stock
This is a microscope accessory that allows a point on the microscope field of view to be singled out for intensity or spectroscopy measurement while the light from the other areas in the field of view are physically blocked out.
A proprietary 4 curtain mechanism allows the user to crop any rectangular region of any size and any aspect ratio in the field of view to be measured while the remaining regions are blocked out. The cropped field of view can be seen through an observation eye piece. A filter drawer allows the use of color glass or interferometric filters for the rejection of undesired wavelengths.
Light transmitted through the cropped region is then directed to an output port where its intensity can be measured by an optional detector or broken down further into its constituent wavelengths via an optional monochromator attachment.
The system is light tight allowing for the use of a photon counting detector. A second output port is also available as an option for dual simultaneous measurements with a dichroic mirror or flipping mirror separating the two ports.

Technical Specifications
Filter Drawer: Accepts 1" diameter or square filters
Output Signal: 0 to 13 V
Output Connection: BNC connector
Usage: With DVM or A/D to computer
Modes: Analog or photon counting
Analytical Area Selector: 4 blade independent slit (or optional iris)
Dimensions: 266.7 x 63.5 x 279.4mm
11,027.00 11027.0 USD
Price Valid only in North America


TLS03 UV-Upgrade
-Extension of wavelength range to: 295-1020 nm
-Calibration for 1 mm distance
-Calibration for PECC-2 Q required, optional

For pricing information, please request a quotation from sales@sciencetech-inc.com.
TLS03 UV-Upgrade
-Extension of wavelength range to: 295-1020 nm
-Calibration for 1 mm distance
-Calibration for PECC-2 Q required, optional

For pricing information, please request a quotation from sales@sciencetech-inc.com.
10,887.00 10887.0 USD
Price Valid only in North America


IM6 (with ColdFire Processor and EPC42 Card only) to CIMPS
-LED potentiostat: PP212
-Current range: ± 10 A
-Voltage range: ± 20 V
-Frequency range: DC - 200 kHz
-LDA2 Light source setup
-Optical bench
-Calibrated feedback sensor
-LSW-1 plug-in LED
-CIMPS aligner bar
-ThalesXT software package
-SIMPECC, CIMPS cable set, calibration data

For pricing information, please request a quotation from sales@sciencetech-inc.com.
IM6 (with ColdFire Processor and EPC42 Card only) to CIMPS
-LED potentiostat: PP212
-Current range: ± 10 A
-Voltage range: ± 20 V
-Frequency range: DC - 200 kHz
-LDA2 Light source setup
-Optical bench
-Calibrated feedback sensor
-LSW-1 plug-in LED
-CIMPS aligner bar
-ThalesXT software package
-SIMPECC, CIMPS cable set, calibration data

For pricing information, please request a quotation from sales@sciencetech-inc.com.
10,751.00 10751.0 USD
Price Valid only in North America


The SSIVT is a complete electrical current-voltage measurement system used to characterize photovoltaic cell performance. This current-voltage tester works by sampling current at different voltages of the photovoltaic cell with a variable impedance load.

This IV measurement system has a separate terminal interface for voltage and current measurements. Each IV curve dataset is saved as a separate ASCII text file.

This I-V Testing Measurement System has a 4 wire Kelvin configuration to remove the resistance effects of the leads and bias the cell at specific voltages.

The I-V Measurement System SSIVT-T20C includes:

A) Keithly Model 2450 - Touchscreen
.Power: 20 W
.Max Voltage: 200V
.Current Range: 1A

B) Sciencetech's SciPV-IV Software for Windows-based control.
.Windows 7/10 32/64 bit

C) RS232 to USB dongle

The SSIVT-2KC works with all Sciencetech Steady State Solar Simulators.

Compatible with Steady State (Continuous) Solar Simulators only.

See brochure for more details.
10,620.00
In stock
The SSIVT is a complete electrical current-voltage measurement system used to characterize photovoltaic cell performance. This current-voltage tester works by sampling current at different voltages of the photovoltaic cell with a variable impedance load.

This IV measurement system has a separate terminal interface for voltage and current measurements. Each IV curve dataset is saved as a separate ASCII text file.

This I-V Testing Measurement System has a 4 wire Kelvin configuration to remove the resistance effects of the leads and bias the cell at specific voltages.

The I-V Measurement System SSIVT-T20C includes:

A) Keithly Model 2450 - Touchscreen
.Power: 20 W
.Max Voltage: 200V
.Current Range: 1A

B) Sciencetech's SciPV-IV Software for Windows-based control.
.Windows 7/10 32/64 bit

C) RS232 to USB dongle

The SSIVT-2KC works with all Sciencetech Steady State Solar Simulators.

Compatible with Steady State (Continuous) Solar Simulators only.

See brochure for more details.
10,620.00 10620.0 USD
Price Valid only in North America


Sciencetech's 621 series power supplies are designed to work with Sciencetech HPLH series lamp houses. The 621-3k is designed to power 2.5kW and 3.0kW xenon and mercury-xenon arc lamps. The 621 power supply includes a touchscreen interface and several useful built in components:
- Lamp life timer
- Powers and controls Sciencetech XLH lamp house fans
- Shutter and exposure controller (24VDC with 12VDC hold)
- RS232 Computer Control (USB to serial adapter included)
- Temperature monitor (optional upgrade)
- Monitor Output (optional upgrade)
- Auto Lamp Start (optional upgrade)
- Safety interlock (optional upgrade)

This product cannot be CE marked

Requires 1 NEMA 6-30P power cable
200-240VAC, 20A

Please see the technical datasheet for more information.
10,321.00
In stock
Sciencetech's 621 series power supplies are designed to work with Sciencetech HPLH series lamp houses. The 621-3k is designed to power 2.5kW and 3.0kW xenon and mercury-xenon arc lamps. The 621 power supply includes a touchscreen interface and several useful built in components:
- Lamp life timer
- Powers and controls Sciencetech XLH lamp house fans
- Shutter and exposure controller (24VDC with 12VDC hold)
- RS232 Computer Control (USB to serial adapter included)
- Temperature monitor (optional upgrade)
- Monitor Output (optional upgrade)
- Auto Lamp Start (optional upgrade)
- Safety interlock (optional upgrade)

This product cannot be CE marked

Requires 1 NEMA 6-30P power cable
200-240VAC, 20A

Please see the technical datasheet for more information.
10,321.00 10321.0 USD
Price Valid only in North America


The TEO-402 is a compact Michelson interferometer module with built-in laser and a broadband IR source. It is designed to be used as a core component in a complete FTIR instrument.
Note that this system does not include a power supply, AD board, or detector.
10,238.00
In stock
The TEO-402 is a compact Michelson interferometer module with built-in laser and a broadband IR source. It is designed to be used as a core component in a complete FTIR instrument.
Note that this system does not include a power supply, AD board, or detector.
10,238.00 10238.0 USD
Price Valid only in North America


An imaging 1/4m Monochromator/spectrograph. It has f/3.5 aperture and a 2D flat field output for multi-channel use. It has a nominal resolution of 0.15 nm.
Special toroidal mirror makes additional astigmatism correction. This spectrograph provides superior image quality over area 25 mm wide and 12 mm high
The unique layout with mirrors of unequal input and output (200mm and 250 mm) focal length is optimized for minimum coma while allowing high throughput and minimum stray light and vignetting
Please contact a technical sales member to discuss coupling options.
For more information, please see the technical datasheet.
10,020.00
In stock
An imaging 1/4m Monochromator/spectrograph. It has f/3.5 aperture and a 2D flat field output for multi-channel use. It has a nominal resolution of 0.15 nm.
Special toroidal mirror makes additional astigmatism correction. This spectrograph provides superior image quality over area 25 mm wide and 12 mm high
The unique layout with mirrors of unequal input and output (200mm and 250 mm) focal length is optimized for minimum coma while allowing high throughput and minimum stray light and vignetting
Please contact a technical sales member to discuss coupling options.
For more information, please see the technical datasheet.
10,020.00 10020.0 USD
Price Valid only in North America


An imaging 1/2 meter monochromator/spectrograph. It has an f/8 aperture and a 2D flat field output for multi-channel use. It has a nominal resolution of 0.1 nm.
Special toroidal mirror makes additional astigmatism correction. This spectrograph provides superior image quality
The unique layout with toroidal mirrors is optimized for minimum coma while allowing high throughput and minimum stray light and vignetting. This option only applies to f/8 triple turrell with 50x50 mm grating holder
Please contact a technical sales member to discuss coupling options.
For more information, please see the technical datasheet.
10,000.00
In stock
An imaging 1/2 meter monochromator/spectrograph. It has an f/8 aperture and a 2D flat field output for multi-channel use. It has a nominal resolution of 0.1 nm.
Special toroidal mirror makes additional astigmatism correction. This spectrograph provides superior image quality
The unique layout with toroidal mirrors is optimized for minimum coma while allowing high throughput and minimum stray light and vignetting. This option only applies to f/8 triple turrell with 50x50 mm grating holder
Please contact a technical sales member to discuss coupling options.
For more information, please see the technical datasheet.
10,000.00 10000.0 USD
Price Valid only in North America


In the 9072DS, the grating in the second monochromator is arranged such that it reverses the spectral dispersion of the first monochromator. This leads to a spectrally homogenized beam at the output port of the second monochromator and greatly reduced stray light, ideal for spectroradiometry, Raman or UV measurements of solar radiation.
The arrangement of the 9072DS allows it to act either as a tunable bandpass filter or a tunable notch filter. Arranged as a tunable bandpass filter the bandpass of the device is determined by the width of an intermediate slit. When arranged as a tunable notch filter the width of the notch is determined by the physical width of an opaque notch placed at the intermediate slit position.
The 9072DS can also be used to pass or filter out several selected wavelengths by using a custom intermediate multi-slit mask instead of a single width intermediate slit.

One SS-80 slit is included, which can be attached to either the input or output port. A second slit can be added to the order if desired.
The fixed intermediate slit or notch filter is not included in the 9072DS and can be selected from any of Sciencetech's SF-series of fixed slits and added to the order. A custom multi-slit mask can be added to the order upon request.
Gratings and grating holders are not included. The 9072DS accommodates 30 × 30 mm gratings, with up to three gratings per turret. Two of each selected grating must be purchased to fill both monochromators. One grating holder is required for each grating.
9,524.00
In stock
In the 9072DS, the grating in the second monochromator is arranged such that it reverses the spectral dispersion of the first monochromator. This leads to a spectrally homogenized beam at the output port of the second monochromator and greatly reduced stray light, ideal for spectroradiometry, Raman or UV measurements of solar radiation.
The arrangement of the 9072DS allows it to act either as a tunable bandpass filter or a tunable notch filter. Arranged as a tunable bandpass filter the bandpass of the device is determined by the width of an intermediate slit. When arranged as a tunable notch filter the width of the notch is determined by the physical width of an opaque notch placed at the intermediate slit position.
The 9072DS can also be used to pass or filter out several selected wavelengths by using a custom intermediate multi-slit mask instead of a single width intermediate slit.

One SS-80 slit is included, which can be attached to either the input or output port. A second slit can be added to the order if desired.
The fixed intermediate slit or notch filter is not included in the 9072DS and can be selected from any of Sciencetech's SF-series of fixed slits and added to the order. A custom multi-slit mask can be added to the order upon request.
Gratings and grating holders are not included. The 9072DS accommodates 30 × 30 mm gratings, with up to three gratings per turret. Two of each selected grating must be purchased to fill both monochromators. One grating holder is required for each grating.
9,524.00 9524.0 USD
Price Valid only in North America
Copyright © Sciencetech