Sciencetech has a large selection of "stand alone" and "open architecture" off-the-shelf and custom made products for researchers using spectroscopy or working with photovoltaics. We offer technical staff to help with the development of custom systems for special applications. Since 1985, Sciencetech has manufactured Modular Instrumentation for Spectroscopy, TeraHertz FTIRs, Highly Collimated Large Solar Simulators, Flash and Continuous Solar Simulators, Photovoltaic Instrumentation, Quantum Efficiency and Spectral Response Systems, Spectrophotometers/radiometers, Monochromators, Detection Systems, and Light Sources to offer to the global research community through a network of representatives.

 here

Sciencetech product design

SCIENCETECH has built a reputation on custom solutions. Whether you need a small modification to an existing system or a completely novel design built from the ground up to meet your technical specifications, Sciencetech's engineering and optical design teams are ready to help.

SCIENCETECH prides itself on our ability to build custom solutions and systems to the most exacting of specifications. Whether you need higher sensitivity, better throughput, more power, better spectral matching, higher resolution, or any other variable modified to give you exactly what you need, our team of engineers, physicists, and optical designers stand ready to provide you with a solution that will meet your technical requirements.

SCIENCETECH'S SOLAR SIMULATORS IN ACTION - The European Commission just released an article involving the use of Sciencetech's solar simulators in their new facility. Read the full article HERE.

X

Product Category

View Filter

x
Clear all x

Filter Option



This option allows the SPS-300 to use both output ports simultaneously. The internal mirror that directs the parallel beam to the converging output is replaced by a large beam splitter which sends half the radiation to the converging output, and the other half to the parallel output.

Please discuss any questions you have regarding the beam splitter, or operating two detectors simultaneously, with your authorized Sciencetech technical sales staff.
This option allows the SPS-300 to use both output ports simultaneously. The internal mirror that directs the parallel beam to the converging output is replaced by a large beam splitter which sends half the radiation to the converging output, and the other half to the parallel output.

Please discuss any questions you have regarding the beam splitter, or operating two detectors simultaneously, with your authorized Sciencetech technical sales staff.
11,288.00 11288.0 USD
Price Valid only in North America


The 9057 is a 0.5 m monochromator and spectrograph with an f/8 aperture. This system is a Czerny-Turner design optimized to reduce aberrations.
This monochromator supports up to three 50x50mm gratings on a computer controlled turret. It includes a single input slit by default; please select appropriate output mounting (slit, detector or CCD mounting, etc...) when ordering. A fast version of the 9057, the 9057F, operates with 64x64mm gratings and offers better throughput with the same optical path length. Please discuss with your Sciencetech technical sales staff member to find if the 9057F is a better choice for your particular application.

It Includes a Sci-Mono, a Windows based software module with a simple graphical user interface for controlling Sciencetech stepping monochromator wavelength selection. SciMono is provided free of charge with a Sciencetech motorized monochromator when SciSpec software has not been purchased. Sciencetech Software (Sci-Spec) is available at an additional cost. It is a standalone data acquisition and allows controlling the monochromator by itself. This system does not include gratings or a host computer. If you require any of these components, please speak with your technical sales staff member.

Refer to the technical datasheet for additional information.

This system includes 1 IEC 60320 C13 compatible power cables. Region-specific version must be selected at the time of placing an order (see product 491-9001).
11,109.00
In Stock
The 9057 is a 0.5 m monochromator and spectrograph with an f/8 aperture. This system is a Czerny-Turner design optimized to reduce aberrations.
This monochromator supports up to three 50x50mm gratings on a computer controlled turret. It includes a single input slit by default; please select appropriate output mounting (slit, detector or CCD mounting, etc...) when ordering. A fast version of the 9057, the 9057F, operates with 64x64mm gratings and offers better throughput with the same optical path length. Please discuss with your Sciencetech technical sales staff member to find if the 9057F is a better choice for your particular application.

It Includes a Sci-Mono, a Windows based software module with a simple graphical user interface for controlling Sciencetech stepping monochromator wavelength selection. SciMono is provided free of charge with a Sciencetech motorized monochromator when SciSpec software has not been purchased. Sciencetech Software (Sci-Spec) is available at an additional cost. It is a standalone data acquisition and allows controlling the monochromator by itself. This system does not include gratings or a host computer. If you require any of these components, please speak with your technical sales staff member.

Refer to the technical datasheet for additional information.

This system includes 1 IEC 60320 C13 compatible power cables. Region-specific version must be selected at the time of placing an order (see product 491-9001).
11,109.00 11109.0 USD
Price Valid only in North America


Sciencetech manufactures grid polarizing beam-splitters for use in the far-infrared and terahertz spectral regions. These beamsplitters divide the incoming beam according to its polarization. The beam-splitter consist of very fine parallel aluminum lines spaced 4 µm apart on a thin mylar substrate. It has the widest spectral range with a higher frequency cut-off than that of other polarizers that work in the near-millimeter wavelength range.
This particular model is 4" (10cm) diameter, and is the second largest size of the IR beam-splitter polarizer Sciencetech offers. For larger or smaller sizes, or for a full list of technical specifications, please speak with your authorized Sciencetech technical sales staff member.
10,635.00
Sciencetech manufactures grid polarizing beam-splitters for use in the far-infrared and terahertz spectral regions. These beamsplitters divide the incoming beam according to its polarization. The beam-splitter consist of very fine parallel aluminum lines spaced 4 µm apart on a thin mylar substrate. It has the widest spectral range with a higher frequency cut-off than that of other polarizers that work in the near-millimeter wavelength range.
This particular model is 4" (10cm) diameter, and is the second largest size of the IR beam-splitter polarizer Sciencetech offers. For larger or smaller sizes, or for a full list of technical specifications, please speak with your authorized Sciencetech technical sales staff member.
10,635.00 10635.0 USD
Price Valid only in North America


The Sciencetech 9055i is a 250 mm asymmetric focal length modified Czerny-Turner monochromator. It has a flat field output for use as a spectrograph, with an area of 25 mm wide and 12 mm high. This model has an f/3.5 aperture. It has a computer-controlled interchangeable turret for automatic grating and wavelength selection. Both the input and output ports are located on the front faceplate of the monochromator, and the system includes one SS80 slit at the input port. CE compliant.

It Includes a Sci-Mono, a Windows based software module with a simple graphical user interface for controlling Sciencetech stepping monochromator wavelength selection. SciMono is provided free of charge with a Sciencetech motorized monochromator when SciSpec software has not been purchased. Sciencetech Software (Sci-Spec) is available at an additional cost. It is a standalone data acquisition and allows controlling the monochromator by itself. This system does not include gratings or a host computer. If you require any of these components, please speak with your technical sales staff member.

Refer to the technical datasheet for additional information.

This system includes 1 IEC 60320 C13 compatible power cables. Region-specific version must be selected at the time of placing an order (see product 491-9001).
10,120.00
In Stock
The Sciencetech 9055i is a 250 mm asymmetric focal length modified Czerny-Turner monochromator. It has a flat field output for use as a spectrograph, with an area of 25 mm wide and 12 mm high. This model has an f/3.5 aperture. It has a computer-controlled interchangeable turret for automatic grating and wavelength selection. Both the input and output ports are located on the front faceplate of the monochromator, and the system includes one SS80 slit at the input port. CE compliant.

It Includes a Sci-Mono, a Windows based software module with a simple graphical user interface for controlling Sciencetech stepping monochromator wavelength selection. SciMono is provided free of charge with a Sciencetech motorized monochromator when SciSpec software has not been purchased. Sciencetech Software (Sci-Spec) is available at an additional cost. It is a standalone data acquisition and allows controlling the monochromator by itself. This system does not include gratings or a host computer. If you require any of these components, please speak with your technical sales staff member.

Refer to the technical datasheet for additional information.

This system includes 1 IEC 60320 C13 compatible power cables. Region-specific version must be selected at the time of placing an order (see product 491-9001).
10,120.00 10120.0 USD
Price Valid only in North America


Class: AAA (ASTM E927-19, IEC 60904-9 Ed.3-2020 classification available upon request)
Target size: 50 × 50 mm
Intensity: 2 Suns using 300 W, 1 Sun using 150 W
ND filter for 1 sun operation included with 300 W version
Working distance: 380 mm (with beam turning unit CTBT-3)
The SciSun can be configured to precisely suit user requirements.
The following features can be selected to provide the best SciSun for your application (see brochure for full details):
- Air Mass Filter: AM1.5G spectral matching included. For AM0 matching, please see the AM0 SciSun product. Other filtering options are possible; please contact us for more details.
- Lamp: 300 W produces a maximum intensity of 2 Suns, 150 W produces a maximum intensity of 1 Sun.
- Power Supply: The included power supply can be a full-featured, adjustable touchscreen-controlled supply, or a simpler, manually-operated power supply.
- Beam Turner: A 360-degree adjustable beam turner is included as a standard feature in all models.
- Stand: Three stand options are available as optional accessories: a simple, economical, height-adjustable stand for downward-facing use (in conjunction with a beam turner), a workstation with adjustable sample tray, and a workstation with adjustable sample tray within a dark chamber. If the system is ordered with no stand, it sits on the tabletop and the beam can be rotated to the desired direction using the beam turner.
- Shutter: A manual shutter is an economical option, while a motorized shutter is available as an optional replacement if computer control of the shutter is required. To control the motorized shutter, the touchscreen power supply option is required.
- Attenuation: Manual or motorized variable attenuators are available optional accessories. If no variable attenuator is chosen, the 300 W SciSun will still come with a removeable neutral density filter to permit 1 sun operation.
Power Requirements: 100–240 VAC, 50/60 Hz, 4.0 A (SciSun-300) or 2.5 A (SciSun-150). This system requires 1 IEC 60320 C13 compatible power cable. Please select 1 region-specific power cable (see product 491-9001) at no cost.
Also included are a xenon arc lamp, filter holder, and testing report.
9,493.00
In Stock
Class: AAA (ASTM E927-19, IEC 60904-9 Ed.3-2020 classification available upon request)
Target size: 50 × 50 mm
Intensity: 2 Suns using 300 W, 1 Sun using 150 W
ND filter for 1 sun operation included with 300 W version
Working distance: 380 mm (with beam turning unit CTBT-3)
The SciSun can be configured to precisely suit user requirements.
The following features can be selected to provide the best SciSun for your application (see brochure for full details):
- Air Mass Filter: AM1.5G spectral matching included. For AM0 matching, please see the AM0 SciSun product. Other filtering options are possible; please contact us for more details.
- Lamp: 300 W produces a maximum intensity of 2 Suns, 150 W produces a maximum intensity of 1 Sun.
- Power Supply: The included power supply can be a full-featured, adjustable touchscreen-controlled supply, or a simpler, manually-operated power supply.
- Beam Turner: A 360-degree adjustable beam turner is included as a standard feature in all models.
- Stand: Three stand options are available as optional accessories: a simple, economical, height-adjustable stand for downward-facing use (in conjunction with a beam turner), a workstation with adjustable sample tray, and a workstation with adjustable sample tray within a dark chamber. If the system is ordered with no stand, it sits on the tabletop and the beam can be rotated to the desired direction using the beam turner.
- Shutter: A manual shutter is an economical option, while a motorized shutter is available as an optional replacement if computer control of the shutter is required. To control the motorized shutter, the touchscreen power supply option is required.
- Attenuation: Manual or motorized variable attenuators are available optional accessories. If no variable attenuator is chosen, the 300 W SciSun will still come with a removeable neutral density filter to permit 1 sun operation.
Power Requirements: 100–240 VAC, 50/60 Hz, 4.0 A (SciSun-300) or 2.5 A (SciSun-150). This system requires 1 IEC 60320 C13 compatible power cable. Please select 1 region-specific power cable (see product 491-9001) at no cost.
Also included are a xenon arc lamp, filter holder, and testing report.
9,493.00 9493.0 USD
Price Valid only in North America


The 9030DS consists of two 100 mm scanning monochromators placed in series in subtractive mode. Bandpass is determined by the width of an intermediate slit, but the 9030DS has a net output dispersion of zero because the monochromators are optically coupled so that the dispersion of the second grating cancels that of the first. This leads to homogenized wavelengths at the output port - there is no spectrum, only a single undispersed slit image - which allows the unit to act as a tunable bandpass or notch filter.

Stray light of all sorts is drastically reduced in a double monochromator, and in the 9030DS it is further minimized by the use of concave holographic gratings. It is ideal for applications where stray light is a problem - where there may be a strong scattered background, such as in spectroradiometry, Raman, or measurements of solar radiation.

The 9030DS can be used as a tunable notch filter to remove one particular wavelength while allowing all others over the bandpass to pass through, making it an ideal instrument to pre-filter out the strong laser excitation wavelength in a fluorescence or Raman system so that the weaker output signals can be observed.

The 9030DS is a fully integrated unit with the two diffraction gratings coupled mechanically for accurate positioning, adjusted manually using a thumb-wheel. It can be upgraded to be motorized and controlled by a computer with the 9030 Motorized Upgrade. Only one motor and drive unit is required for both monochromators, enabling control via Sciencetech Sci-Mono Active-X library or full featured Sci-Spec software.

The Model 9030DS can also be used to pass or filter out several selected wavelengths by using a custom intermediate multi-slit mask instead of a single width intermediate slit. Please contact a Sciencetech Applications Specialist for such custom wavelength filtering.

Mirror coatings have been chosen for this model to enhance performance in the UV-VIS region. There are 5 grating choices (sold separately) covering from UV to near-IR; choose a UV to VIS range to pair with the UV/VIS mirror coatings on this model. Two gratings are required.

Please add a minimum of three slits (for the input, output, and intermediate position) separately. Several removable fixed-width slit sizes are available to choose from ranging from 50 μm to 3 mm width. Please note that a 50μm slit may introduce some artifacts when used with the 9030 - this model is recommended to be used with slits of 100μm or larger for best performance in most applications. Additional removable slits and custom width slits can also be purchased.
Available slits include:
Model Slit Width
SF005 - 50 μm
SF010 - 100μm
SF025 - 250μm
SF050 - 500μm
SF100 - 1mm
SF200 - 2mm
SF300 - 3mm
9,493.00
In Stock
The 9030DS consists of two 100 mm scanning monochromators placed in series in subtractive mode. Bandpass is determined by the width of an intermediate slit, but the 9030DS has a net output dispersion of zero because the monochromators are optically coupled so that the dispersion of the second grating cancels that of the first. This leads to homogenized wavelengths at the output port - there is no spectrum, only a single undispersed slit image - which allows the unit to act as a tunable bandpass or notch filter.

Stray light of all sorts is drastically reduced in a double monochromator, and in the 9030DS it is further minimized by the use of concave holographic gratings. It is ideal for applications where stray light is a problem - where there may be a strong scattered background, such as in spectroradiometry, Raman, or measurements of solar radiation.

The 9030DS can be used as a tunable notch filter to remove one particular wavelength while allowing all others over the bandpass to pass through, making it an ideal instrument to pre-filter out the strong laser excitation wavelength in a fluorescence or Raman system so that the weaker output signals can be observed.

The 9030DS is a fully integrated unit with the two diffraction gratings coupled mechanically for accurate positioning, adjusted manually using a thumb-wheel. It can be upgraded to be motorized and controlled by a computer with the 9030 Motorized Upgrade. Only one motor and drive unit is required for both monochromators, enabling control via Sciencetech Sci-Mono Active-X library or full featured Sci-Spec software.

The Model 9030DS can also be used to pass or filter out several selected wavelengths by using a custom intermediate multi-slit mask instead of a single width intermediate slit. Please contact a Sciencetech Applications Specialist for such custom wavelength filtering.

Mirror coatings have been chosen for this model to enhance performance in the UV-VIS region. There are 5 grating choices (sold separately) covering from UV to near-IR; choose a UV to VIS range to pair with the UV/VIS mirror coatings on this model. Two gratings are required.

Please add a minimum of three slits (for the input, output, and intermediate position) separately. Several removable fixed-width slit sizes are available to choose from ranging from 50 μm to 3 mm width. Please note that a 50μm slit may introduce some artifacts when used with the 9030 - this model is recommended to be used with slits of 100μm or larger for best performance in most applications. Additional removable slits and custom width slits can also be purchased.
Available slits include:
Model Slit Width
SF005 - 50 μm
SF010 - 100μm
SF025 - 250μm
SF050 - 500μm
SF100 - 1mm
SF200 - 2mm
SF300 - 3mm
9,493.00 9493.0 USD
Price Valid only in North America


The 9030DA double additive monochromator consists of two 9030 monochromators placed in series. Stray light is drastically reduced in a double monochromator, and in the 9030DA it is further minimized by the use of concave holographic gratings. The inbound light is dispersed by the first grating and again by the second. Both gratings rotate simultaneously in the same direction, and the monochromators are coupled so that the dispersion is double that of a single 9030 monochromator. Bandpass is half of the corresponding 9030 monochromator for the same output slit, and resolution using a 100 µm slit is 0.4 nm.

Mirror coatings have been chosen for this model to enhance performance in the UV-VIS spectral region. There are 5 grating choices (sold separately) covering from UV to near-IR; choose a UV to VIS range to pair with the UV/VIS mirror coatings on this model. Two gratings are required.

The 9030DA is a fully integrated unit with the two diffraction gratings coupled mechanically for accurate positioning, adjusted manually using a thumb-wheel. It can be upgraded to be motorized and controlled by a computer with the 9030 Motorized Upgrade. Only one motor and drive unit is required for both monochromators, enabling control via Sciencetech Sci-Mono Active-X library or full featured Sci-Spec software.

Please add a minimum of three slits (for the input, output, and intermediate position) separately. Several removable fixed-width slit sizes are available to choose from ranging from 50 μm to 3 mm width. Please note that a 50μm slit may introduce some artifacts when used with the 9030 - this model is recommended to be used with slits of 100μm or larger for best performance in most applications. Additional removable slits and custom width slits can also be purchased.
Available slits include:
Model Slit Width
SF005 - 50 μm
SF010 - 100μm
SF025 - 250μm
SF050 - 500μm
SF100 - 1mm
SF200 - 2mm
SF300 - 3mm
9,493.00
In Stock
The 9030DA double additive monochromator consists of two 9030 monochromators placed in series. Stray light is drastically reduced in a double monochromator, and in the 9030DA it is further minimized by the use of concave holographic gratings. The inbound light is dispersed by the first grating and again by the second. Both gratings rotate simultaneously in the same direction, and the monochromators are coupled so that the dispersion is double that of a single 9030 monochromator. Bandpass is half of the corresponding 9030 monochromator for the same output slit, and resolution using a 100 µm slit is 0.4 nm.

Mirror coatings have been chosen for this model to enhance performance in the UV-VIS spectral region. There are 5 grating choices (sold separately) covering from UV to near-IR; choose a UV to VIS range to pair with the UV/VIS mirror coatings on this model. Two gratings are required.

The 9030DA is a fully integrated unit with the two diffraction gratings coupled mechanically for accurate positioning, adjusted manually using a thumb-wheel. It can be upgraded to be motorized and controlled by a computer with the 9030 Motorized Upgrade. Only one motor and drive unit is required for both monochromators, enabling control via Sciencetech Sci-Mono Active-X library or full featured Sci-Spec software.

Please add a minimum of three slits (for the input, output, and intermediate position) separately. Several removable fixed-width slit sizes are available to choose from ranging from 50 μm to 3 mm width. Please note that a 50μm slit may introduce some artifacts when used with the 9030 - this model is recommended to be used with slits of 100μm or larger for best performance in most applications. Additional removable slits and custom width slits can also be purchased.
Available slits include:
Model Slit Width
SF005 - 50 μm
SF010 - 100μm
SF025 - 250μm
SF050 - 500μm
SF100 - 1mm
SF200 - 2mm
SF300 - 3mm
9,493.00 9493.0 USD
Price Valid only in North America


The 9030DA double additive monochromator consists of two 9030 monochromators placed in series. Stray light is drastically reduced in a double monochromator, and in the 9030DA it is further minimized by the use of concave holographic gratings. The inbound light is dispersed by the first grating and again by the second. Both gratings rotate simultaneously in the same direction, and the monochromators are coupled so that the dispersion is double that of a single 9030 monochromator. Bandpass is half of the corresponding 9030 monochromator for the same output slit, and resolution using a 100 µm slit is 0.4 nm.

Mirror coatings have been chosen for this model to enhance performance in the VIS-NIR spectral region. There are 5 grating choices (sold separately) covering from UV to near-IR; choose a VIS to NIR range to pair with the VIS/IR mirror coatings on this model. Two gratings are required.

The 9030DA is a fully integrated unit with the two diffraction gratings coupled mechanically for accurate positioning, adjusted manually using a thumb-wheel. It can be upgraded to be motorized and controlled by a computer with the 9030 Motorized Upgrade. Only one motor and drive unit is required for both monochromators, enabling control via Sciencetech Sci-Mono Active-X library or full featured Sci-Spec software.

Please add a minimum of three slits (for the input, output, and intermediate position) separately. Several removable fixed-width slit sizes are available to choose from ranging from 50 μm to 3 mm width. Please note that a 50μm slit may introduce some artifacts when used with the 9030 - this model is recommended to be used with slits of 100μm or larger for best performance in most applications. Additional removable slits and custom width slits can also be purchased.
Available slits include:
Model Slit Width
SF005 - 50 μm
SF010 - 100μm
SF025 - 250μm
SF050 - 500μm
SF100 - 1mm
SF200 - 2mm
SF300 - 3mm
9,493.00
In Stock
The 9030DA double additive monochromator consists of two 9030 monochromators placed in series. Stray light is drastically reduced in a double monochromator, and in the 9030DA it is further minimized by the use of concave holographic gratings. The inbound light is dispersed by the first grating and again by the second. Both gratings rotate simultaneously in the same direction, and the monochromators are coupled so that the dispersion is double that of a single 9030 monochromator. Bandpass is half of the corresponding 9030 monochromator for the same output slit, and resolution using a 100 µm slit is 0.4 nm.

Mirror coatings have been chosen for this model to enhance performance in the VIS-NIR spectral region. There are 5 grating choices (sold separately) covering from UV to near-IR; choose a VIS to NIR range to pair with the VIS/IR mirror coatings on this model. Two gratings are required.

The 9030DA is a fully integrated unit with the two diffraction gratings coupled mechanically for accurate positioning, adjusted manually using a thumb-wheel. It can be upgraded to be motorized and controlled by a computer with the 9030 Motorized Upgrade. Only one motor and drive unit is required for both monochromators, enabling control via Sciencetech Sci-Mono Active-X library or full featured Sci-Spec software.

Please add a minimum of three slits (for the input, output, and intermediate position) separately. Several removable fixed-width slit sizes are available to choose from ranging from 50 μm to 3 mm width. Please note that a 50μm slit may introduce some artifacts when used with the 9030 - this model is recommended to be used with slits of 100μm or larger for best performance in most applications. Additional removable slits and custom width slits can also be purchased.
Available slits include:
Model Slit Width
SF005 - 50 μm
SF010 - 100μm
SF025 - 250μm
SF050 - 500μm
SF100 - 1mm
SF200 - 2mm
SF300 - 3mm
9,493.00 9493.0 USD
Price Valid only in North America


The 9030DS consists of two 100 mm scanning monochromators placed in series in subtractive mode. Bandpass is determined by the width of an intermediate slit, but the 9030DS has a net output dispersion of zero because the monochromators are optically coupled so that the dispersion of the second grating cancels that of the first. This leads to homogenized wavelengths at the output port - there is no spectrum, only a single undispersed slit image - which allows the unit to act as a tunable bandpass or notch filter.

Stray light of all sorts is drastically reduced in a double monochromator, and in the 9030DS it is further minimized by the use of concave holographic gratings. It is ideal for applications where stray light is a problem - where there may be a strong scattered background, such as in spectroradiometry, Raman, or measurements of solar radiation.

The 9030DS can be used as a tunable notch filter to remove one particular wavelength while allowing all others over the bandpass to pass through, making it an ideal instrument to pre-filter out the strong laser excitation wavelength in a fluorescence or Raman system so that the weaker output signals can be observed.

The 9030DS is a fully integrated unit with the two diffraction gratings coupled mechanically for accurate positioning, adjusted manually using a thumb-wheel. It can be upgraded to be motorized and controlled by a computer with the 9030 Motorized Upgrade. Only one motor and drive unit is required for both monochromators, enabling control via Sciencetech Sci-Mono Active-X library or full featured Sci-Spec software.

The Model 9030DS can also be used to pass or filter out several selected wavelengths by using a custom intermediate multi-slit mask instead of a single width intermediate slit. Please contact a Sciencetech Applications Specialist for such custom wavelength filtering.

Mirror coatings have been chosen for this model to enhance performance in the VIS-NIR region. There are 5 grating choices (sold separately) covering from UV to near-IR; choose a VIS to NIR range to pair with the VIS/IR mirror coatings on this model. Two gratings are required.

Please add a minimum of three slits (for the input, output, and intermediate position) separately. Several removable fixed-width slit sizes are available to choose from ranging from 50 μm to 3 mm width. Please note that a 50μm slit may introduce some artifacts when used with the 9030 - this model is recommended to be used with slits of 100μm or larger for best performance in most applications. Additional removable slits and custom width slits can also be purchased.
Available slits include:
Model Slit Width
SF005 - 50 μm
SF010 - 100μm
SF025 - 250μm
SF050 - 500μm
SF100 - 1mm
SF200 - 2mm
SF300 - 3mm
9,493.00
In Stock
The 9030DS consists of two 100 mm scanning monochromators placed in series in subtractive mode. Bandpass is determined by the width of an intermediate slit, but the 9030DS has a net output dispersion of zero because the monochromators are optically coupled so that the dispersion of the second grating cancels that of the first. This leads to homogenized wavelengths at the output port - there is no spectrum, only a single undispersed slit image - which allows the unit to act as a tunable bandpass or notch filter.

Stray light of all sorts is drastically reduced in a double monochromator, and in the 9030DS it is further minimized by the use of concave holographic gratings. It is ideal for applications where stray light is a problem - where there may be a strong scattered background, such as in spectroradiometry, Raman, or measurements of solar radiation.

The 9030DS can be used as a tunable notch filter to remove one particular wavelength while allowing all others over the bandpass to pass through, making it an ideal instrument to pre-filter out the strong laser excitation wavelength in a fluorescence or Raman system so that the weaker output signals can be observed.

The 9030DS is a fully integrated unit with the two diffraction gratings coupled mechanically for accurate positioning, adjusted manually using a thumb-wheel. It can be upgraded to be motorized and controlled by a computer with the 9030 Motorized Upgrade. Only one motor and drive unit is required for both monochromators, enabling control via Sciencetech Sci-Mono Active-X library or full featured Sci-Spec software.

The Model 9030DS can also be used to pass or filter out several selected wavelengths by using a custom intermediate multi-slit mask instead of a single width intermediate slit. Please contact a Sciencetech Applications Specialist for such custom wavelength filtering.

Mirror coatings have been chosen for this model to enhance performance in the VIS-NIR region. There are 5 grating choices (sold separately) covering from UV to near-IR; choose a VIS to NIR range to pair with the VIS/IR mirror coatings on this model. Two gratings are required.

Please add a minimum of three slits (for the input, output, and intermediate position) separately. Several removable fixed-width slit sizes are available to choose from ranging from 50 μm to 3 mm width. Please note that a 50μm slit may introduce some artifacts when used with the 9030 - this model is recommended to be used with slits of 100μm or larger for best performance in most applications. Additional removable slits and custom width slits can also be purchased.
Available slits include:
Model Slit Width
SF005 - 50 μm
SF010 - 100μm
SF025 - 250μm
SF050 - 500μm
SF100 - 1mm
SF200 - 2mm
SF300 - 3mm
9,493.00 9493.0 USD
Price Valid only in North America


This device is designed to be coupled to one of Sciencetech's IV Test systems. The Load Booster is inserted between the Keithley and the device under test with the Keithley current range set to 0.1A and used in remote (4 wire) sensing mode. The Load Booster effectively expands the IV testing current range.
Load Boosters may only be used in pulsed mode operation. They cannot be used for continuous illumination and measurement.
Voltage Range: 200V
Current Range: 80A

8,585.00
This device is designed to be coupled to one of Sciencetech's IV Test systems. The Load Booster is inserted between the Keithley and the device under test with the Keithley current range set to 0.1A and used in remote (4 wire) sensing mode. The Load Booster effectively expands the IV testing current range.
Load Boosters may only be used in pulsed mode operation. They cannot be used for continuous illumination and measurement.
Voltage Range: 200V
Current Range: 80A

8,585.00 8585.0 USD
Price Valid only in North America


The Sciencetech 9055 is a 250mm asymmetric focal length modified Czerny-Turner monochromator. It has a flat field output for use as a spectrograph. This model has an f/3.5 aperture (for the "Fast" version with f/2.5, please see the 9055F). It has a computer-controlled interchangeable turret for automatic grating and wavelength selection.
Both the input and output ports are located on the front faceplate of the monochromator, and the system includes one SS80 slit at the input port. CE compliant.

It Includes a Sci-Mono, a Windows based software module with a simple graphical user interface for controlling Sciencetech stepping monochromator wavelength selection. SciMono is provided free of charge with a Sciencetech motorized monochromator when SciSpec software has not been purchased. Sciencetech Software (Sci-Spec) is available at an additional cost. It is a standalone data acquisition and allows controlling the monochromator by itself. This system does not include gratings or a host computer. If you require any of these components, please speak with your technical sales staff member.

Refer to the technical datasheet for additional information.

This system includes 1 IEC 60320 C13 compatible power cables. Region-specific version must be selected at the time of placing an order (see product 491-9001).
8,538.00
In Stock
The Sciencetech 9055 is a 250mm asymmetric focal length modified Czerny-Turner monochromator. It has a flat field output for use as a spectrograph. This model has an f/3.5 aperture (for the "Fast" version with f/2.5, please see the 9055F). It has a computer-controlled interchangeable turret for automatic grating and wavelength selection.
Both the input and output ports are located on the front faceplate of the monochromator, and the system includes one SS80 slit at the input port. CE compliant.

It Includes a Sci-Mono, a Windows based software module with a simple graphical user interface for controlling Sciencetech stepping monochromator wavelength selection. SciMono is provided free of charge with a Sciencetech motorized monochromator when SciSpec software has not been purchased. Sciencetech Software (Sci-Spec) is available at an additional cost. It is a standalone data acquisition and allows controlling the monochromator by itself. This system does not include gratings or a host computer. If you require any of these components, please speak with your technical sales staff member.

Refer to the technical datasheet for additional information.

This system includes 1 IEC 60320 C13 compatible power cables. Region-specific version must be selected at the time of placing an order (see product 491-9001).
8,538.00 8538.0 USD
Price Valid only in North America


Sciencetech manufactures grid polarizing beam-splitters for use in the far-infrared and terahertz spectral regions. These beamsplitters divide the incoming beam according to its polarization. The beam-splitter consist of very fine parallel aluminum lines spaced 4 µm apart on a thin mylar substrate. It has the widest spectral range with a higher frequency cut-off than that of other polarizers that work in the near-millimeter wavelength range.
This particular model is 3" (7.5cm) diameter, and is the middle size of the IR beam-splitter polarizer Sciencetech offers. For larger or smaller sizes, or for a full list of technical specifications, please speak with your authorized Sciencetech technical sales staff member.
8,509.00
Sciencetech manufactures grid polarizing beam-splitters for use in the far-infrared and terahertz spectral regions. These beamsplitters divide the incoming beam according to its polarization. The beam-splitter consist of very fine parallel aluminum lines spaced 4 µm apart on a thin mylar substrate. It has the widest spectral range with a higher frequency cut-off than that of other polarizers that work in the near-millimeter wavelength range.
This particular model is 3" (7.5cm) diameter, and is the middle size of the IR beam-splitter polarizer Sciencetech offers. For larger or smaller sizes, or for a full list of technical specifications, please speak with your authorized Sciencetech technical sales staff member.
8,509.00 8509.0 USD
Price Valid only in North America


The Glow bar (Globar) is a typical infrared source for the THz researcher. The heating element itself is very low cost, allowing researchers to use them without worry about replacing expensive bulbs or components. The majority of the price for this unit consists of the water cooling (required for vacuum operation), large reflector to efficiently collect the radiation, and housing designed to withstand the high level of vacuum required for THz operation.
This model is specifically designed to mount to the optional External Input Port of the SPS300. If you wish to use a completed Globar unit for your own applications, please speak with a Technical Support specialist.
Please note that this device requires water cooling to operate under vacuum and includes all the lines, but not the water recirculator itself. If purchased as part of a complete SPS300 system, it is included.
The Glow bar (Globar) is a typical infrared source for the THz researcher. The heating element itself is very low cost, allowing researchers to use them without worry about replacing expensive bulbs or components. The majority of the price for this unit consists of the water cooling (required for vacuum operation), large reflector to efficiently collect the radiation, and housing designed to withstand the high level of vacuum required for THz operation.
This model is specifically designed to mount to the optional External Input Port of the SPS300. If you wish to use a completed Globar unit for your own applications, please speak with a Technical Support specialist.
Please note that this device requires water cooling to operate under vacuum and includes all the lines, but not the water recirculator itself. If purchased as part of a complete SPS300 system, it is included.
8,181.00 8181.0 USD
Price Valid only in North America


This device is designed to be coupled to one of Sciencetech's IV Test systems. The Load Booster is inserted between the Keithley and the device under test with the Keithley current range set to 0.1A and used in remote (4 wire) sensing mode. The Load Booster effectively expands the IV testing current range.
Load Boosters may only be used in pulsed mode operation. They cannot be used for continuous illumination and measurement.
Voltage Range: 200V
Current Range: 60A
8,080.00
This device is designed to be coupled to one of Sciencetech's IV Test systems. The Load Booster is inserted between the Keithley and the device under test with the Keithley current range set to 0.1A and used in remote (4 wire) sensing mode. The Load Booster effectively expands the IV testing current range.
Load Boosters may only be used in pulsed mode operation. They cannot be used for continuous illumination and measurement.
Voltage Range: 200V
Current Range: 60A
8,080.00 8080.0 USD
Price Valid only in North America


A 6" x 6" (152.4 mm x 152.4 mm) air mass filter specifically designed for Sciencetech's Fresnel Solar Simulator Series (SHC-), including filter holder. The AM0 spectrum simulates the solar spectrum just outside Earth’s atmosphere, where there is very little atmosphere-related absorption of solar radiation. This is generally used for space applications.
8,075.00
In Stock
A 6" x 6" (152.4 mm x 152.4 mm) air mass filter specifically designed for Sciencetech's Fresnel Solar Simulator Series (SHC-), including filter holder. The AM0 spectrum simulates the solar spectrum just outside Earth’s atmosphere, where there is very little atmosphere-related absorption of solar radiation. This is generally used for space applications.
8,075.00 8075.0 USD
Price Valid only in North America


4kW max average power, 100mm aperture, water-cooled. Doesn't require monitor, includes USB cable and PC-HP application software.

Sensitivity 0.4 mW/W,
rise time 7 sec,
spectral range 0.19-20um.
7,990.00
In Stock
4kW max average power, 100mm aperture, water-cooled. Doesn't require monitor, includes USB cable and PC-HP application software.

Sensitivity 0.4 mW/W,
rise time 7 sec,
spectral range 0.19-20um.
7,990.00 7990.0 USD
Price Valid only in North America


Target size: 500x500mm
DAQ: 16 bit
Detector size : 20x20mm
Detector Type: SCI-REF-LR
Connectivity: 1 x USB2.0
Power Requirements: 120VAC x 4A / 220VAC x 2A
Dimensions: 800x800x125
7,550.00
In Stock
Target size: 500x500mm
DAQ: 16 bit
Detector size : 20x20mm
Detector Type: SCI-REF-LR
Connectivity: 1 x USB2.0
Power Requirements: 120VAC x 4A / 220VAC x 2A
Dimensions: 800x800x125
7,550.00 7550.0 USD
Price Valid only in North America


Lamp Power: 300W
Lamp Type: Xenon
Output Beam Type: Collimated
Output Beam Diameter: 50mm (2")
Lens Type: Three lens system
Lens Material: Fused Silica
Ozone Producing: No

Sciencetech's Research Grade Arc Lamp Source Packages come with all the components required to operate a research-quality xenon arc lamp source: power supply, arc lamp housing, output optics, and lamp.

These systems feature a configurable housing capable of being operated in the vertical or horizontal position. Each housing comes with adjustable base plates for both configurations, allowing easy alignment of the lamp to the rest of the optical system.

Power and communication are supplied to the housing via a single cable connected to the touchscreen power supply, allowing users to easily and neatly set up the system. A safety interlock prevents power being supplied to the housing while the cover is open, protecting users from electric shock or unwanted light exposure.

Three fused silica lenses in the optical assembly give least possible spherical aberration and permit maximum UV output.

This system includes 1 IEC 60320 C13 compatible power cable. Region-specific version must be selected at the time of placing an order (see product 491-9001).

Optional accessories include a downward facing stand, beam turner, alternative optical packages, optical filter holders and filter boxes, and filters.
7,444.00
In Stock
Lamp Power: 300W
Lamp Type: Xenon
Output Beam Type: Collimated
Output Beam Diameter: 50mm (2")
Lens Type: Three lens system
Lens Material: Fused Silica
Ozone Producing: No

Sciencetech's Research Grade Arc Lamp Source Packages come with all the components required to operate a research-quality xenon arc lamp source: power supply, arc lamp housing, output optics, and lamp.

These systems feature a configurable housing capable of being operated in the vertical or horizontal position. Each housing comes with adjustable base plates for both configurations, allowing easy alignment of the lamp to the rest of the optical system.

Power and communication are supplied to the housing via a single cable connected to the touchscreen power supply, allowing users to easily and neatly set up the system. A safety interlock prevents power being supplied to the housing while the cover is open, protecting users from electric shock or unwanted light exposure.

Three fused silica lenses in the optical assembly give least possible spherical aberration and permit maximum UV output.

This system includes 1 IEC 60320 C13 compatible power cable. Region-specific version must be selected at the time of placing an order (see product 491-9001).

Optional accessories include a downward facing stand, beam turner, alternative optical packages, optical filter holders and filter boxes, and filters.
7,444.00 7444.0 USD
Price Valid only in North America


This lamp housing design is optimized for 1600 W xenon arc lamps. It features a F/2.5 elliptical reflector.

Lamp Power: 1600 W
Lamp Type: Xenon, Ozone free (included)
Reflector Type: Elliptical
Power Supply: PS-XE1600-A-T (sold separately)

All Sciencetech XLH lamp housings feature a configurable and upgradeable housing capable of being operated in the vertical or horizontal position.

Power and communication are supplied to the housing via a single cable connected to the touchscreen power supply, allowing users to easily and neatly set up the system. A safety interlock prevents power being supplied to the housing while the cover is open, protecting users from electric shock or unwanted light exposure.

A wide variety of collimated or focused output optics is available for use with the XLH-series, allowing a full range of sizes, materials, and coatings for optics to best suit the requirement. A wide variety of accessories is also available, including downward-facing stands, optical intensity feedback, and more.
7,373.00
This lamp housing design is optimized for 1600 W xenon arc lamps. It features a F/2.5 elliptical reflector.

Lamp Power: 1600 W
Lamp Type: Xenon, Ozone free (included)
Reflector Type: Elliptical
Power Supply: PS-XE1600-A-T (sold separately)

All Sciencetech XLH lamp housings feature a configurable and upgradeable housing capable of being operated in the vertical or horizontal position.

Power and communication are supplied to the housing via a single cable connected to the touchscreen power supply, allowing users to easily and neatly set up the system. A safety interlock prevents power being supplied to the housing while the cover is open, protecting users from electric shock or unwanted light exposure.

A wide variety of collimated or focused output optics is available for use with the XLH-series, allowing a full range of sizes, materials, and coatings for optics to best suit the requirement. A wide variety of accessories is also available, including downward-facing stands, optical intensity feedback, and more.
7,373.00 7373.0 USD
Price Valid only in North America


This is a room-temperature detector for use with the SPS-300. This includes the DTGS detector with a mounting flange, but requires the use of a dual-phase lock-in amplifier (sold separately). Sciencetech's wideband detector design comes packaged in a mounting flange compatible with our SPS-300. It is connectorized to be powered directly from the Stanford SR-810/830 type lock-in amplifiers with a detachable cable. The spectral range is limited by window selection. This detector comes with a HDPE window standard.

Element size: 2.0 mm dia.
Spectral bandwidth: 16 to 100um (for HDPE window, other window materials available)
Frequency response: 10Hz - 265Hz (-3db points)
N.E.P.: 5x10-10 watts (@100Hz)
Power requirements: +/- 15 to +/- 24 volts max @ +/- 8 mA max.
Power connections:
DB-9M
Pins 2,3,4,5,9 no connection
+V In Pin 1
-V In Pin 6
Common Pin 7
Case GND Pin 8
Signal Connection: BNC

Suitable for direct connection to Stanford SR-810/830 lockin preamp power (not included).

This is a room-temperature detector for use with the SPS-300. This includes the DTGS detector with a mounting flange, but requires the use of a dual-phase lock-in amplifier (sold separately).
This is a room-temperature detector for use with the SPS-300. This includes the DTGS detector with a mounting flange, but requires the use of a dual-phase lock-in amplifier (sold separately). Sciencetech's wideband detector design comes packaged in a mounting flange compatible with our SPS-300. It is connectorized to be powered directly from the Stanford SR-810/830 type lock-in amplifiers with a detachable cable. The spectral range is limited by window selection. This detector comes with a HDPE window standard.

Element size: 2.0 mm dia.
Spectral bandwidth: 16 to 100um (for HDPE window, other window materials available)
Frequency response: 10Hz - 265Hz (-3db points)
N.E.P.: 5x10-10 watts (@100Hz)
Power requirements: +/- 15 to +/- 24 volts max @ +/- 8 mA max.
Power connections:
DB-9M
Pins 2,3,4,5,9 no connection
+V In Pin 1
-V In Pin 6
Common Pin 7
Case GND Pin 8
Signal Connection: BNC

Suitable for direct connection to Stanford SR-810/830 lockin preamp power (not included).

This is a room-temperature detector for use with the SPS-300. This includes the DTGS detector with a mounting flange, but requires the use of a dual-phase lock-in amplifier (sold separately).
7,272.00 7272.0 USD