Electrochemical Workstations | Sciencetech Inc.

Electrochemical Workstations

Zahner Electrochemical Instruments

High Quality Expert Instruments

A Potentiostat is used in with a three electrode cell to perform a myriad of electrochemical experiments, ranging from measuring half-cell potentials, impedance spectroscopy, redox chemistry, and chemical phenomena. These experiments are relevant for corrosion studies, battery chemistry development, materials characterization and more. 

Sciencetech is pleased to represent Zahner in Canada. With 40 years of experience in the field, Zahner’s high-quality electrochemical instruments are backed by years of expertise. Zahner’s systems are an excellent choice for many applications such as corrosion testing, photoelectrochemistry, fuel cell testing, and Li-ion battery testing .

Zahner potentiostats are designed to provide the highest level of performance in electrochemical experiments and have been proven to be precise and versatile devices for any kind of electrochemical application. Zahner potentiostats can be equipped with multiple plug and play add-on cards, which introduce additional analog and digital input/output signals. This modular function makes Zahner's potentiostats very flexible and allows the possibility to customize the potentiostat to suit the needs of its users. 

Zahner Zennium X

Zennium

Electrochemical Workstation


The core of the Zahner instrumentation is an electrochemical workstation. With the Zennium, Zennium E, Zennium-pro, and Zennium-X, there is a workstation available to support the most advanced techniques, as well as a cost-effective option for more straightforward applications. Supported by the Thales software, many different techniques can be accessed from the same software interface, making the Zahner line convenient and easy to use.

With modular components to add on, accessories for your specific technique can be simply and easily added to your workstation, customizing your setup for your specific requirements.

CIMPS Instruments

Photoelectrochemistry


For photoelectrochemistry, the CIMPS instruments are a powerful choice. With a light source included and kept stable by a control loop, considerations such as non-linearity, ageing, and temperature drift no longer need be considered. The package includes the light source (driven by an included slave potentiostat), optical bench, photoelectrochemical cell, and all required software. For QE and IPCE measurements, consider the CIMPS-QE/IPCE package, including all necessary components to collect QE and IPCE measurements from your sample.

The Zahner CIMPS measurement system has been designed with focus on the special demands of dynamic photo-electric investigations like IMPS and IMVS, popular today for instance in alternative solar cell research. Besides all traditional electrochemical investigations supported by THALES - like impedance measurements, cyclic voltammetry, current-potential curves, etc. - now mixed photo electric transfer functions, known as Intensity Modulated Photo Spectra(IMPS/IMVS), can be measured. 

Zahner CIMPS

Electrochemical Workstation Models

Product Comparison

With the following electrochemical workstations available as a base, you can perform many measurements with the workstation alone or choose add-ons to customize your capabilities for your specific requirements:

Contact Us Today
Get more information or request a quote.
X

Product Category

View Filter

x
Clear all x

Filter Option



The XPOT2 as a high precision auxiliary potentiostat adds an additional channel to the ZENNIUM series potentiostat for bi-potentiostat functionality. The combination of ZENNIUM and XPOT2 enables rotating ring disk electrode (RRDE) measurements or hydrogen permeation in Devanathan cells. The XPOT2 provides up to ±500 mA output current and up to ±25 V compliance voltage. The XPOT2 contains 9 current ranges which enable it to carry out outstandingly precise and accurate measurements.

In addition, the XPOT2 potentiostat can also be used as a standalone potentiostat and can be controlled by Zahner-Lab.

The Zahner's potentiostats can be incorporated in a Python lab environment and can be used as stand-alone or in multi-channel configurations. A GitHub repository with examples is available for developing Python applications.

-Standalone operation and possible integration in a Python work environment
-Extension for bipotentiostat applications

For pricing information, please request a quotation from sales@sciencetech-inc.com.
The XPOT2 as a high precision auxiliary potentiostat adds an additional channel to the ZENNIUM series potentiostat for bi-potentiostat functionality. The combination of ZENNIUM and XPOT2 enables rotating ring disk electrode (RRDE) measurements or hydrogen permeation in Devanathan cells. The XPOT2 provides up to ±500 mA output current and up to ±25 V compliance voltage. The XPOT2 contains 9 current ranges which enable it to carry out outstandingly precise and accurate measurements.

In addition, the XPOT2 potentiostat can also be used as a standalone potentiostat and can be controlled by Zahner-Lab.

The Zahner's potentiostats can be incorporated in a Python lab environment and can be used as stand-alone or in multi-channel configurations. A GitHub repository with examples is available for developing Python applications.

-Standalone operation and possible integration in a Python work environment
-Extension for bipotentiostat applications

For pricing information, please request a quotation from sales@sciencetech-inc.com.
5,473.00 5473.0 USD
Price Valid only in North America


The battery cycling multiplexer BC-MUX is the link between the high power performances of your battery cycler and the EIS precision of our ZENNIUM potentiostats. The BC-MUX can address up to 16 channels to sequentially perform EIS measurements on the connected samples.

Switchboxes which serve as ports between the BC-MUX and the cycler are available as 16 A, 60 A, 150 A or custom made options.

-Sequential measurements on up to 16 channels
-Non-selected channels are connected to the battery cycler

For pricing information, please request a quotation from sales@sciencetech-inc.com.
The battery cycling multiplexer BC-MUX is the link between the high power performances of your battery cycler and the EIS precision of our ZENNIUM potentiostats. The BC-MUX can address up to 16 channels to sequentially perform EIS measurements on the connected samples.

Switchboxes which serve as ports between the BC-MUX and the cycler are available as 16 A, 60 A, 150 A or custom made options.

-Sequential measurements on up to 16 channels
-Non-selected channels are connected to the battery cycler

For pricing information, please request a quotation from sales@sciencetech-inc.com.
5,191.00 5191.0 USD
Price Valid only in North America


The Zahner PAD4 card provides 4 additional voltage or current input channels which can be used for parallel DC or EIS measurements on segments connected in series. The PAD4 card is an optimal addition to the ZENNIUM potentiostat for stack measurements or segmented cells.

The PAD4 card is used in the fuel cell, electrolyzer stack and battery-pack investigations. In addition, it is used in measurements involving a reference electrode in a 3-electrode cell connection scheme.

Parallel EIS measurements on each segment in a stack enable highly detailed measurement system behavior either in-plane or throughout the stack. Up to 17 EIS signals can be recorded in a frequency range of 10 µHz to 250 kHz. 18-bit AD converters ensure high-quality EIS data.

Overview of PAD4 card variants:
PAD4-HC: for investigation of individual cells in a stack of up to ±100V
PAD4-LC: for investigation of segmented cells in a stack of up to ±25 V
PAD4-HZ: for investigation of batteries with high-resistance reference electrodes or high-resistance objects

-Parallel EIS stack measurements
-Up to 17 channels for ZENNIUM X
-Up to 5 channels for ZENNIUM PRO
-Customizable voltage range for PAD4 channels
-Incorporated with external potentiostats and electronic loads
-3 different models for stacks and segmented cells

For pricing information, please request a quotation from sales@sciencetech-inc.com.
The Zahner PAD4 card provides 4 additional voltage or current input channels which can be used for parallel DC or EIS measurements on segments connected in series. The PAD4 card is an optimal addition to the ZENNIUM potentiostat for stack measurements or segmented cells.

The PAD4 card is used in the fuel cell, electrolyzer stack and battery-pack investigations. In addition, it is used in measurements involving a reference electrode in a 3-electrode cell connection scheme.

Parallel EIS measurements on each segment in a stack enable highly detailed measurement system behavior either in-plane or throughout the stack. Up to 17 EIS signals can be recorded in a frequency range of 10 µHz to 250 kHz. 18-bit AD converters ensure high-quality EIS data.

Overview of PAD4 card variants:
PAD4-HC: for investigation of individual cells in a stack of up to ±100V
PAD4-LC: for investigation of segmented cells in a stack of up to ±25 V
PAD4-HZ: for investigation of batteries with high-resistance reference electrodes or high-resistance objects

-Parallel EIS stack measurements
-Up to 17 channels for ZENNIUM X
-Up to 5 channels for ZENNIUM PRO
-Customizable voltage range for PAD4 channels
-Incorporated with external potentiostats and electronic loads
-3 different models for stacks and segmented cells

For pricing information, please request a quotation from sales@sciencetech-inc.com.
5,153.00 5153.0 USD
Price Valid only in North America


Processor Upgrade for IM6 series
-ColdFire CPU board with USB-interface
-Slot covers, USB cable
-HD removal & backup (if possible)
-Factory calibration
-ThalesXT software
-System is controlled by a Windows7/8/10-PC (not included)

For pricing information, please request a quotation from sales@sciencetech-inc.com.
Processor Upgrade for IM6 series
-ColdFire CPU board with USB-interface
-Slot covers, USB cable
-HD removal & backup (if possible)
-Factory calibration
-ThalesXT software
-System is controlled by a Windows7/8/10-PC (not included)

For pricing information, please request a quotation from sales@sciencetech-inc.com.
4,824.00 4824.0 USD
Price Valid only in North America


The PMUX-P is configured for sequentially measuring through up to 16 segments of segmented electrodes, e.g., of a fuel cell. For that application, a PP series potentiostat or an EL series electronic load is used for loading all segments except the one which is measured. The measurement is done by the internal ZENNIUM potentiostat. The software carries out sequential measurements through all segments of the fuel cell. With one PMUX-P these are up to 16 segments. Up to 4 PMUX-P modules can be stacked for a total of up to 64 segments. Both, the PP/EL and the ZENNIUM potentiostat have to be connected to the PMUX-P.

-Up to 64 channel segmented cells

For pricing information, please request a quotation from sales@sciencetech-inc.com.
The PMUX-P is configured for sequentially measuring through up to 16 segments of segmented electrodes, e.g., of a fuel cell. For that application, a PP series potentiostat or an EL series electronic load is used for loading all segments except the one which is measured. The measurement is done by the internal ZENNIUM potentiostat. The software carries out sequential measurements through all segments of the fuel cell. With one PMUX-P these are up to 16 segments. Up to 4 PMUX-P modules can be stacked for a total of up to 64 segments. Both, the PP/EL and the ZENNIUM potentiostat have to be connected to the PMUX-P.

-Up to 64 channel segmented cells

For pricing information, please request a quotation from sales@sciencetech-inc.com.
4,627.00 4627.0 USD
Price Valid only in North America


The PMUX-S power multiplexer is used to simultaneously contact the ZENNIUM series potentiostat with up to 16 individual cells. The measurements are carried out sequentially. For medium power applications, our power potentiostats can also be connected. The PMUX-S can be used for cell currents up to ±5 A.

-4 PMUX-S can be used for connecting up to 64 cells

For pricing information, please request a quotation from sales@sciencetech-inc.com.
The PMUX-S power multiplexer is used to simultaneously contact the ZENNIUM series potentiostat with up to 16 individual cells. The measurements are carried out sequentially. For medium power applications, our power potentiostats can also be connected. The PMUX-S can be used for cell currents up to ±5 A.

-4 PMUX-S can be used for connecting up to 64 cells

For pricing information, please request a quotation from sales@sciencetech-inc.com.
4,376.00 4376.0 USD
Price Valid only in North America


CIMPS Add-on for Photo-Electrochemical Light Emission
-SEL033 NIST traceable sensor
-CIMPS-emit software for integral measurements

For pricing information, please request a quotation from sales@sciencetech-inc.com.
CIMPS Add-on for Photo-Electrochemical Light Emission
-SEL033 NIST traceable sensor
-CIMPS-emit software for integral measurements

For pricing information, please request a quotation from sales@sciencetech-inc.com.
3,608.00 3608.0 USD
Price Valid only in North America


NIST-traceable calibration sensor
-For automatic calibration procedure at the customer's lab.

For pricing information, please request a quotation from sales@sciencetech-inc.com.
NIST-traceable calibration sensor
-For automatic calibration procedure at the customer's lab.

For pricing information, please request a quotation from sales@sciencetech-inc.com.
3,571.00 3571.0 USD
Price Valid only in North America


Upgrade: Cypress to FTDI USB Chip
-Including calibration of workstation

For pricing information, please request a quotation from sales@sciencetech-inc.com.
Upgrade: Cypress to FTDI USB Chip
-Including calibration of workstation

For pricing information, please request a quotation from sales@sciencetech-inc.com.
3,333.00 3333.0 USD
Price Valid only in North America


Photo-electrochemical cell
-Quartz front window
-Illuminated area 18 mm diam.
-Solid material: PCTFE
-Gas-proof with gas-in/outlet
-Ag/AgCl reference electrode & Pt counter-electrode
-Cable-set
-Dimensions: 60 x 25 x 80 mm; Volume: 7.2 cm³
-For photocurrent spectroscopy with TLS03, PECC-2 calibration is required

For pricing information, please request a quotation from sales@sciencetech-inc.com.
Photo-electrochemical cell
-Quartz front window
-Illuminated area 18 mm diam.
-Solid material: PCTFE
-Gas-proof with gas-in/outlet
-Ag/AgCl reference electrode & Pt counter-electrode
-Cable-set
-Dimensions: 60 x 25 x 80 mm; Volume: 7.2 cm³
-For photocurrent spectroscopy with TLS03, PECC-2 calibration is required

For pricing information, please request a quotation from sales@sciencetech-inc.com.
3,276.00 3276.0 USD
Price Valid only in North America


Photo-Electrochemical Cell

The PECC-1/PECC-2 are specially tailored for testing electrode materials with photoelectrochemical techniques. Several mounting options for samples offer flexibility for various tasks.

Front and rear window 18 mm diam., BK7 or quartz
Solid material: PCTFE
Gas-proof with gas-in/outlet
Ag/AgCl reference electrode & Pt counter-electrode
Cable set
Dimensions: 60 x 25 x 80 mm

For pricing information, please request a quotation from sales@sciencetech-inc.com.
Photo-Electrochemical Cell

The PECC-1/PECC-2 are specially tailored for testing electrode materials with photoelectrochemical techniques. Several mounting options for samples offer flexibility for various tasks.

Front and rear window 18 mm diam., BK7 or quartz
Solid material: PCTFE
Gas-proof with gas-in/outlet
Ag/AgCl reference electrode & Pt counter-electrode
Cable set
Dimensions: 60 x 25 x 80 mm

For pricing information, please request a quotation from sales@sciencetech-inc.com.
3,186.00 3186.0 USD
Price Valid only in North America


Corrosion Cell Kit

The corrosion measuring cell KMZ5 is a triple electrode water-jacket cell for standard electrochemical measurements with a cell container suitable for connection to constant temperature circulators.

The measuring cell has different cell tops with standard taper joints (NS) for the insertion of the working and the counter electrodes, as well as the intermediate vessel with reference electrode and liquid junction tube including a ""Haber Luggin capilary"". All electrodes have glass bodies with standard tapers. The cell features a user-friendly handling and a wide range of applications.

KMZ5 comes with: specimen holder (WE), counter electrode, reference electrode (Calomel), liquid junction tube, intermediate vessel, gas in- and outlet.

Double-wall glass vessel for temperature control
3-electrode configuration
Pt counter electrode
Ag/AgCl reference electrode
Sample holder
Thermometer

For pricing information, please request a quotation from sales@sciencetech-inc.com.
Corrosion Cell Kit

The corrosion measuring cell KMZ5 is a triple electrode water-jacket cell for standard electrochemical measurements with a cell container suitable for connection to constant temperature circulators.

The measuring cell has different cell tops with standard taper joints (NS) for the insertion of the working and the counter electrodes, as well as the intermediate vessel with reference electrode and liquid junction tube including a ""Haber Luggin capilary"". All electrodes have glass bodies with standard tapers. The cell features a user-friendly handling and a wide range of applications.

KMZ5 comes with: specimen holder (WE), counter electrode, reference electrode (Calomel), liquid junction tube, intermediate vessel, gas in- and outlet.

Double-wall glass vessel for temperature control
3-electrode configuration
Pt counter electrode
Ag/AgCl reference electrode
Sample holder
Thermometer

For pricing information, please request a quotation from sales@sciencetech-inc.com.
3,071.00 3071.0 USD
Price Valid only in North America


Light Exclusion Box / Faradays Cage
-Fitting for CIMPS optical rail
-For all CIMPS light sources incl. TLS03 (not for Solar Simulators)
-Easy handling by hinged top/sides and three cable inlets
-Ground connector for shielding (Faradays Cage function)
-Dimensions: 60 x 33 x 23 cm (W x D x H) without handle

For pricing information, please request a quotation from sales@sciencetech-inc.com.
Light Exclusion Box / Faradays Cage
-Fitting for CIMPS optical rail
-For all CIMPS light sources incl. TLS03 (not for Solar Simulators)
-Easy handling by hinged top/sides and three cable inlets
-Ground connector for shielding (Faradays Cage function)
-Dimensions: 60 x 33 x 23 cm (W x D x H) without handle

For pricing information, please request a quotation from sales@sciencetech-inc.com.
2,948.00 2948.0 USD
Price Valid only in North America


Lightsource LS 275
-Dom. wavelength: 275 nm
-Typ. intensity: 40 W/m²
-Max. input current: 1300 mA

For pricing information, please request a quotation from sales@sciencetech-inc.com.
Lightsource LS 275
-Dom. wavelength: 275 nm
-Typ. intensity: 40 W/m²
-Max. input current: 1300 mA

For pricing information, please request a quotation from sales@sciencetech-inc.com.
2,872.00 2872.0 USD
Price Valid only in North America


The Noise Probe is a low power potentiostat for the ZENNIUM-series potentiostats and is specially designed for all common electrochemical noise techniques. In addition Zahner developed CorrElNoise®. This revolutionary new method is superior to common ECN techniques as it measures the current and voltage noise in (quasi-)parallel condition by fast switching between the open circuit potential and short circuit conditions.

The Noise Probe can carry out different kind of measurements which are listed below.

-Open circuit potential noise (OCPN)
-Potentiostatic controlled current noise (PCCN)
-Galvanostatic controlled potential noise (GCPN)
-Uncorrelated current & potential noise (UCPN)
-Correlated electrochemical noise (CorrElNoise®)

For pricing information, please request a quotation from sales@sciencetech-inc.com.
The Noise Probe is a low power potentiostat for the ZENNIUM-series potentiostats and is specially designed for all common electrochemical noise techniques. In addition Zahner developed CorrElNoise®. This revolutionary new method is superior to common ECN techniques as it measures the current and voltage noise in (quasi-)parallel condition by fast switching between the open circuit potential and short circuit conditions.

The Noise Probe can carry out different kind of measurements which are listed below.

-Open circuit potential noise (OCPN)
-Potentiostatic controlled current noise (PCCN)
-Galvanostatic controlled potential noise (GCPN)
-Uncorrelated current & potential noise (UCPN)
-Correlated electrochemical noise (CorrElNoise®)

For pricing information, please request a quotation from sales@sciencetech-inc.com.
2,850.00 2850.0 USD
Price Valid only in North America


Tool-Kit for Coating and Laminate Testing
-Cu-block, steel-electrodes
-Electrolyte carrier and buffer solution
-Cable set
-Electrode stand
-COLT software

For pricing information, please request a quotation from sales@sciencetech-inc.com.
Tool-Kit for Coating and Laminate Testing
-Cu-block, steel-electrodes
-Electrolyte carrier and buffer solution
-Cable set
-Electrode stand
-COLT software

For pricing information, please request a quotation from sales@sciencetech-inc.com.
2,754.00 2754.0 USD
Price Valid only in North America


Corrosion Cell Kit

The corrosion measuring cell KMZ3 is a triple electrode non-water-jacketed cell for standard electrochemical measurements.

The measuring cell has different cell tops with standard taper joints (NS) for the insertion of the working and the counter electrodes, as well as the intermediate vessel with reference electrode and liquid junction tube including a ""Haber Luggin capilary"". All electrodes have glass bodies with standard tapers. The cell features a user-friendly handling and a wide range of applications.

KMZ3 comes with: specimen holder (WE), counter electrode, reference electrode (Calomel), liquid junction tube, intermediate vessel, gas in- and outlet.

Glass vessel
3-electrode configuration
Pt counter electrode
Ag/AgCl reference electrode
Sample holder

For pricing information, please request a quotation from sales@sciencetech-inc.com.
Corrosion Cell Kit

The corrosion measuring cell KMZ3 is a triple electrode non-water-jacketed cell for standard electrochemical measurements.

The measuring cell has different cell tops with standard taper joints (NS) for the insertion of the working and the counter electrodes, as well as the intermediate vessel with reference electrode and liquid junction tube including a ""Haber Luggin capilary"". All electrodes have glass bodies with standard tapers. The cell features a user-friendly handling and a wide range of applications.

KMZ3 comes with: specimen holder (WE), counter electrode, reference electrode (Calomel), liquid junction tube, intermediate vessel, gas in- and outlet.

Glass vessel
3-electrode configuration
Pt counter electrode
Ag/AgCl reference electrode
Sample holder

For pricing information, please request a quotation from sales@sciencetech-inc.com.
2,548.00 2548.0 USD
Price Valid only in North America


Lightsource LS 1550
-Dom. wavelength: 1550 nm
-Typ. intensity: 40 W/m²
-Max. input current: 800 mA

For pricing information, please request a quotation from sales@sciencetech-inc.com.
Lightsource LS 1550
-Dom. wavelength: 1550 nm
-Typ. intensity: 40 W/m²
-Max. input current: 800 mA

For pricing information, please request a quotation from sales@sciencetech-inc.com.
2,472.00 2472.0 USD
Price Valid only in North America


Lightsource LS 1450
-Dom. wavelength: 1450 nm
-Max. input current: 800 mA

For pricing information, please request a quotation from sales@sciencetech-inc.com.
Lightsource LS 1450
-Dom. wavelength: 1450 nm
-Max. input current: 800 mA

For pricing information, please request a quotation from sales@sciencetech-inc.com.
2,472.00 2472.0 USD
Price Valid only in North America


Lightsource LS 1300
-Dom. wavelength: 1300 nm
-Typ. intensity: 60 W/m²
-Max. input current: 800 mA

For pricing information, please request a quotation from sales@sciencetech-inc.com.
Lightsource LS 1300
-Dom. wavelength: 1300 nm
-Typ. intensity: 60 W/m²
-Max. input current: 800 mA

For pricing information, please request a quotation from sales@sciencetech-inc.com.
2,472.00 2472.0 USD
Price Valid only in North America
Copyright © Sciencetech