Modular Spectrometers

Modular Spectroscopy Overview chart:

MONOCHROMATORS AND SPECTROGRAPHS


MODEL

FOCAL LENGTH (mm)

F/#

RESOLUTION (nm)

DISPERSION (nm/mm)

TURRET CONFIGURATION

SPECIAL FEATURES

SMALL SERIES

9030

100

F/3.2

1

8

Single Grating 32mm x 32mm

Compact Monochromator

9030DA

100x2

F/3.2

0.5

4

Single Grating 32mm x 32mm

Double Additive

9030DS

100x2

F/3.2

1

Effectively 0

Single Grating 32mm x 32mm

Double Subtractive

9072

125

F/3.5

0.4

7

Triple Grating 30mm x 30mm

Motorized Compact Monochromator

9072DA

125x2

F/3.5

0.2

3.5

Triple Grating 30mm x 30mm

Double Additive

9072DS

125x2

F/3.5

0.4

Effectively 0

Triple Grating 30mm x 30mm

Double Subtractive

STANDARD SERIES

9010

200

F/3.5

0.4

4

Double Grating 50mm x 50mm

Manual Monochromator/Spectrograph

9055

250

F/3.5

0.2

4

Triple Grating 50mm x 50mm

Motorized Monochromator/Spectrograph

9055F

250

F/2.5

0.4

3.3

Double Grating 64mm x 64mm

Fast Version Motorized Monochromator/Spectrograph

9055DX

250x2

F/3.5

0.1

1.7

Triple Grating 50mm x 50mm

Motorized Double Additive/Subtractive

9055DX-i

250x2

F/3.5

0.09

1.7

Triple Grating 50mm x 50mm

Motorized Imaging Monochromator/Spectrograph

9057

457

F/8

0.2

1.79

Triple Grating 50mm x 50mm

Half Meter Motorized Monochromator/Spectrograph

9057i

457

F/8

0.1

1.79

Triple Grating 50mm x 50mm

Half Meter Motorized Imaging Monochromator/Spectrograph

9057F

457

F/5.9

0.1

1.79

Triple Grating 64mm x 64mm

Fast Version Half Meter Motorized Monochromator/Spectrograph

HIGH RESOLUTION SERIES

9040-1G 9040-3G

550

F/6.9

0.03

1.53

Single Grating 64mmx64mm
Up to 3 gratings 64mm x 64mm

Half Meter High Resolution

9040F

550

F/5.2

0.03

1.53

Single Grating 84mm x 84mm

Half Meter High Resolution Fast Version

9040EF

550

F/4.0

0.05

1.53

Single Grating 110mm x 110mm

Half Meter High Performace

9040-DX (DS Configuration)

550

F/6.9

0.03

Effectively 0

Single Grating 64mm x 64mm

Half Meter High Resolution Double Subtractive

9040DX (DA Configuration)

550

F/6.9

0.015

4

Single Grating 64mm x 64mm

Half Meter High Resolution Double Additive

9490

1000

F/13

0.017

0.83

Up to 3 gratings 64mm x 64mm

One Meter High Resolution

9490SD

1000

F/13

0.009

0.42

Up to 3 gratings 64mm x 64mm

One Meter High Resolution Single/Double Pass

9150

1500

F/12

0.013

0.5

Single Grating 110mm x 110mm

One and a Half Meter High Resolution

9150SD

1500x2

F/12

0.0063

0.25

Single Grating 110mm x 110mm

One and a Half Meter Single/Double Pass

9150X

1500

F/25

N/A

1pm/1px

Special gratings

One and a Half Meter Echelle Spectrometer

 


 

X

Product Category

View Filter

x
Clear all x

Filter Option



In the 9072DS, the grating in the second monochromator is arranged such that it reverses the spectral dispersion of the first monochromator. This leads to a spectrally homogenized beam at the output port of the second monochromator and greatly reduced stray light, ideal for spectroradiometry, Raman or UV measurements of solar radiation.
The arrangement of the 9072DS allows it to act either as a tunable bandpass filter or a tunable notch filter. Arranged as a tunable bandpass filter the bandpass of the device is determined by the width of an intermediate slit. When arranged as a tunable notch filter the width of the notch is determined by the physical width of an opaque notch placed at the intermediate slit position.
The 9072DS can also be used to pass or filter out several selected wavelengths by using a custom intermediate multi-slit mask instead of a single width intermediate slit.

One SS-80 slit is included, which can be attached to either the input or output port. A second slit can be added to the order if desired.
The fixed intermediate slit or notch filter is not included in the 9072DS and can be selected from any of Sciencetech's SF-series of fixed slits and added to the order. A custom multi-slit mask can be added to the order upon request.
Gratings and grating holders are not included. The 9072DS accommodates 30 × 30 mm gratings, with up to three gratings per turret. Two of each selected grating must be purchased to fill both monochromators. One grating holder is required for each grating.

This system includes 2 IEC 60320 C13 compatible power cables. Region-specific version must be selected at the time of placing an order (see product 491-9001).
20,195.00
In Stock
In the 9072DS, the grating in the second monochromator is arranged such that it reverses the spectral dispersion of the first monochromator. This leads to a spectrally homogenized beam at the output port of the second monochromator and greatly reduced stray light, ideal for spectroradiometry, Raman or UV measurements of solar radiation.
The arrangement of the 9072DS allows it to act either as a tunable bandpass filter or a tunable notch filter. Arranged as a tunable bandpass filter the bandpass of the device is determined by the width of an intermediate slit. When arranged as a tunable notch filter the width of the notch is determined by the physical width of an opaque notch placed at the intermediate slit position.
The 9072DS can also be used to pass or filter out several selected wavelengths by using a custom intermediate multi-slit mask instead of a single width intermediate slit.

One SS-80 slit is included, which can be attached to either the input or output port. A second slit can be added to the order if desired.
The fixed intermediate slit or notch filter is not included in the 9072DS and can be selected from any of Sciencetech's SF-series of fixed slits and added to the order. A custom multi-slit mask can be added to the order upon request.
Gratings and grating holders are not included. The 9072DS accommodates 30 × 30 mm gratings, with up to three gratings per turret. Two of each selected grating must be purchased to fill both monochromators. One grating holder is required for each grating.

This system includes 2 IEC 60320 C13 compatible power cables. Region-specific version must be selected at the time of placing an order (see product 491-9001).
20,195.00 20195.0 USD

Price Valid only in North America
Copyright © Sciencetech