Optical Components | Sciencetech Inc.

Optical Components

X

Product Category

View Filter

x
Clear all x

Filter Option



Sun Screen Testing Industry standard filters for isolating UVA wavelengths (320-400nm)
Schott UG11 Filter for eliminating visible and infrared rays (>400nm)
Schott WG335/3mm or WG345/1mm filter for eliminating UVB and UVC rays (<320nm)
Used in the UVA Protection Factor Test Method (Persistent Pigment Darkening)
900.00
In stock
Sun Screen Testing Industry standard filters for isolating UVA wavelengths (320-400nm)
Schott UG11 Filter for eliminating visible and infrared rays (>400nm)
Schott WG335/3mm or WG345/1mm filter for eliminating UVB and UVC rays (<320nm)
Used in the UVA Protection Factor Test Method (Persistent Pigment Darkening)
900.00 900.0 USD
Price Valid only in North America


.
3,500.00 3500.0 USD
Price Valid only in North America


This assembly is a custom F/# matched lens assembly. It is a double lens assembly of 2" diameter PCX lenses.
Lens material is BK7 Glass.
Specify required F/# at time of ordering. F/# can be set from F/0.8 to F/10.0
Lenses mounted in 2.2" diameter coupling tube. Accessories and adapters for coupling available.
522.00
In stock
This assembly is a custom F/# matched lens assembly. It is a double lens assembly of 2" diameter PCX lenses.
Lens material is BK7 Glass.
Specify required F/# at time of ordering. F/# can be set from F/0.8 to F/10.0
Lenses mounted in 2.2" diameter coupling tube. Accessories and adapters for coupling available.
522.00 522.0 USD
Price Valid only in North America


Sciencetech's sample chambers can be connected to either the input or output port of a Sciencetech monochromator/spectrograph. The coupling tube that connects them together is 1" in diameter, and has one lens with a matching monochromator F number. When the sample chamber is connected to the input port of a monochromator/spectrograph, collimated light from the sample chamber is then focused into the slit of the monochromator matching its input F number using a single lens. When the sample chamber is connected to the output port of a monochromator, the output light of the monochromator is collected by a single lens with matching output F number and then collimated for entry into the sample chamber.
This product includes the F-matching lens, tubes, and mechanical connections required to couple the sample chamber to the monochromator. Please specify if this will be an input or output coupling when ordering. This product will only work for Sciencetech's line of sample chambers: for custom optical coupling, please speak with your authorized Sciencetech technical sales staff member.
909.00
In stock
Sciencetech's sample chambers can be connected to either the input or output port of a Sciencetech monochromator/spectrograph. The coupling tube that connects them together is 1" in diameter, and has one lens with a matching monochromator F number. When the sample chamber is connected to the input port of a monochromator/spectrograph, collimated light from the sample chamber is then focused into the slit of the monochromator matching its input F number using a single lens. When the sample chamber is connected to the output port of a monochromator, the output light of the monochromator is collected by a single lens with matching output F number and then collimated for entry into the sample chamber.
This product includes the F-matching lens, tubes, and mechanical connections required to couple the sample chamber to the monochromator. Please specify if this will be an input or output coupling when ordering. This product will only work for Sciencetech's line of sample chambers: for custom optical coupling, please speak with your authorized Sciencetech technical sales staff member.
909.00 909.0 USD
Price Valid only in North America


.
730.00 730.0 USD
Price Valid only in North America


.
730.00 730.0 USD
Price Valid only in North America


This assembly is a customizable F/# matched, 1" diameter, double lens assembly.
The Lens material selected will be Fused Quartz or Fused Silica depending on availability. Best used in the spectral range 250-2500nm

The CON1 lens assemblies are designed to accept collimated light and produce a focused beam at the intended target location
Please specify the required F/# at time of ordering. F/# can be set from F/0.8 to F/10.0
The required F/# must be entered in the sales order notes for efficient processing

Accessories and adapters for coupling available.
585.00
In stock
This assembly is a customizable F/# matched, 1" diameter, double lens assembly.
The Lens material selected will be Fused Quartz or Fused Silica depending on availability. Best used in the spectral range 250-2500nm

The CON1 lens assemblies are designed to accept collimated light and produce a focused beam at the intended target location
Please specify the required F/# at time of ordering. F/# can be set from F/0.8 to F/10.0
The required F/# must be entered in the sales order notes for efficient processing

Accessories and adapters for coupling available.
585.00 585.0 USD
Price Valid only in North America


This assembly is a custom F/# matched lens assembly. It is a double lens assembly of 2" diameter PCX lenses.
Lens material is Fused Quartz or Fused Silica depending on availability.
Specify required F/# at time of ordering. F/# can be set from F/0.8 to F/10.0
Lenses mounted in 2.2" diameter coupling tube. Accessories and adapters for coupling available.
881.00
In stock
This assembly is a custom F/# matched lens assembly. It is a double lens assembly of 2" diameter PCX lenses.
Lens material is Fused Quartz or Fused Silica depending on availability.
Specify required F/# at time of ordering. F/# can be set from F/0.8 to F/10.0
Lenses mounted in 2.2" diameter coupling tube. Accessories and adapters for coupling available.
881.00 881.0 USD
Price Valid only in North America


.
3,500.00 3500.0 USD
Price Valid only in North America


.
730.00 730.0 USD
Price Valid only in North America


.
730.00 730.0 USD
Price Valid only in North America


.
730.00 730.0 USD
Price Valid only in North America


A Longpass filter designed for use with Sciencetech systems in the Infrared range.
Diameter (mm) 25.0
Diameter Tolerance (mm) +0.0 / -0.1
Thickness (mm) 1.0
Thickness Tolerance (mm) ±0.2
Clear Aperture (%) 90
Surface Accuracy (λ) 3 - 5
Surface Quality 60-40
Parallelism (arcminutes) <10
Transmission (%) >90
Transmission Wavelength (μm) 2.52 - 4.80
Optical Density OD >3.0
Cut-On Wavelength (μm) 2.40
Cut-On Wavelength Tolerance (μm) 0.09
Cut-On Tolerance (%) 5 of Peak Transmission
Slope Factor (%) <6
Substrate Germanium
Operating Temperature (°C) -62 to +71
RoHS Compliant

Please speak with your authorized Sciencetech technical sales staff for a full list of specifications.
416.00
In stock
A Longpass filter designed for use with Sciencetech systems in the Infrared range.
Diameter (mm) 25.0
Diameter Tolerance (mm) +0.0 / -0.1
Thickness (mm) 1.0
Thickness Tolerance (mm) ±0.2
Clear Aperture (%) 90
Surface Accuracy (λ) 3 - 5
Surface Quality 60-40
Parallelism (arcminutes) <10
Transmission (%) >90
Transmission Wavelength (μm) 2.52 - 4.80
Optical Density OD >3.0
Cut-On Wavelength (μm) 2.40
Cut-On Wavelength Tolerance (μm) 0.09
Cut-On Tolerance (%) 5 of Peak Transmission
Slope Factor (%) <6
Substrate Germanium
Operating Temperature (°C) -62 to +71
RoHS Compliant

Please speak with your authorized Sciencetech technical sales staff for a full list of specifications.
416.00 416.0 USD
Price Valid only in North America


Four filter sort order filter set covers a spectral 200-1600nm range (UV-NIR).
Order sorting filters are used with diffractive equipment such as monochromators to filter out harmonic diffractive orders.
This absorbing glass sort order filter set provides modest harmonic blocking for spectroscopy systems.

Filters are 1" diameter

Note: absorbing glass type filters may exhibit flourescence. These filters cannot be used with high power light sources
450.00
In stock
Four filter sort order filter set covers a spectral 200-1600nm range (UV-NIR).
Order sorting filters are used with diffractive equipment such as monochromators to filter out harmonic diffractive orders.
This absorbing glass sort order filter set provides modest harmonic blocking for spectroscopy systems.

Filters are 1" diameter

Note: absorbing glass type filters may exhibit flourescence. These filters cannot be used with high power light sources
450.00 450.0 USD
Price Valid only in North America


.
500.00 500.0 USD
Price Valid only in North America


Wavelength range: 400-1600nm
Dispersion: 16nm/mm (When used with 9030 monochromator)
1,593.00
In stock
Wavelength range: 400-1600nm
Dispersion: 16nm/mm (When used with 9030 monochromator)
1,593.00 1593.0 USD
Price Valid only in North America


A 6" x 6" (152.4 mm x 152.4 mm) air mass filter specifically designed for Sciencetech's Fresnel Solar Simulator Series, including filter holder. The AM0 spectrum simulates the solar spectrum just outside Earth’s atmosphere, where there is very little atmosphere-related absorption of solar radiation. This is generally used for space applications.
4,133.00
In stock
A 6" x 6" (152.4 mm x 152.4 mm) air mass filter specifically designed for Sciencetech's Fresnel Solar Simulator Series, including filter holder. The AM0 spectrum simulates the solar spectrum just outside Earth’s atmosphere, where there is very little atmosphere-related absorption of solar radiation. This is generally used for space applications.
4,133.00 4133.0 USD
Price Valid only in North America


This filter is part of Sciencetech's standard "Order Sorting Filter Set". It can be ordered separately if required.
Please see the technical datasheet for additional information.
20.00
In stock
This filter is part of Sciencetech's standard "Order Sorting Filter Set". It can be ordered separately if required.
Please see the technical datasheet for additional information.
20.00 20.0 USD
Price Valid only in North America


Wavelength range: 300-1200nm
Dispersion: 12nm/mm (When used with 9030 monochromator)
1,450.00
In stock
Wavelength range: 300-1200nm
Dispersion: 12nm/mm (When used with 9030 monochromator)
1,450.00 1450.0 USD
Price Valid only in North America


.
730.00 730.0 USD
Price Valid only in North America
Copyright © Sciencetech