Standard USD Pricelist
Sign in
x
Toggle navigation
Home
Products
Light Sources
Xe Arc Lamp Light Source
Low Power Xe 75W - 150W
Medium Power Xe 300W
High Power Xe 500W - 1600W
Ultra High Power Xe 3000W - 7000W
Deuterium Light Sources
QTH Light Sources
Tunable Light Sources
Calibration Light Sources
Infrared Light Sources
Solar Simulators
Steady State Solar Simulator
Ultra High Efficiency Solar Simulators
Fully Reflective Solar Simulators
Low Cost Solar Simulators
Highly Collimated Solar Simulators
Large Area Solar Simulators
UV Solar Simulators
Fiberized Solar Simulators
High Flux & Concentrator Solar Simulators
Flash Solar Simulators
Large Area Flash Solar Simulators
Highly Collimated Flash Solar Simulators
Concentrator Flash Solar Simulators
Solar Cell IV Testing Equipment
Solar Cell IV Testing Equipment for Steady State Solar Simulators
Solar Cell IV Testing Equipment for Flash Solar Simulators
Quantum Efficiency
Modular Spectrometers
FTIR Spectrometers
Monochromators and Spectrographs
Small Series
Standard Series
High Resolution Series
Integrated and Modular Systems
Spectroradiometer For Detector Characterization
Spectrophotometry
Fluorescence Spectroscopy
Raman Spectroscopy
LIBS Spectrometer
Far Infrared Systems (THz)
Far Infrared Spectrometers
Electrochemical Workstations
Potentiostats
Addons Cards
External Potentiostats
Probes
Multiplexers
Extension and Cell Kits
Photoelectrochemistry & Photovoltaic
Electronic Loads
Upgrades
Accessories / Parts
Cell Chucks
Data Acquisition Equipment
Other Accessories
Sample Chambers
Software
Power Supply
Calibration Cells and Power Meters
Detectors
Single Channel Detector
Line and Area Detectors
Lamps
Xenon Short Arc Lamps
Mercury Xenon Short Arc Lamp
Mercury Short Arc Lamps
QTH Lamps
Infrared Lamps
Optical Components
Bandpass Filters
Filters
Gratings
Filters for Solar Simulation
Reflectors
Optical Coupling Assemblies
Optomechanical
Integrating Spheres
Slit Assemblies
Beam Turning Units
Filter Holders
Filter Wheels
Shutter Assemblies
Optical Choppers
Adapters and Connectors
True
Custom Solutions
Custom Solutions Overview
Success Stories
Custom Capabilities
Applications
Photovoltaic Testing Equipment
Space Environment Simulation
Solar Simulators for Materials Testing
Solar Thermal Applications
About
About Us
Press Releases
Contact us
Sales Contact
Representatives
Support Contact
Knowledge Centre
Detectors
Single Channel Detector
Line and Area Detectors
View As
2
4
Prev
1
2
Next
Filter
View Filter
show
16
20
Sort by
Price
Price
Name
X
Product Category
View Filter
All Products
Light Sources
Xe Arc Lamp Light Source
Low Power Xe 75W - 150W
Medium Power Xe 300W
High Power Xe 500W - 1600W
Ultra High Power Xe 3000W - 7000W
Deuterium Light Sources
QTH Light Sources
Tunable Light Sources
Calibration Light Sources
Infrared Light Sources
Solar Simulators
Steady State Solar Simulator
Ultra High Efficiency Solar Simulators
Fully Reflective Solar Simulators
Low Cost Solar Simulators
Highly Collimated Solar Simulators
Large Area Solar Simulators
UV Solar Simulators
Fiberized Solar Simulators
High Flux & Concentrator Solar Simulators
Flash Solar Simulators
Large Area Flash Solar Simulators
Highly Collimated Flash Solar Simulators
Concentrator Flash Solar Simulators
Solar Cell IV Testing Equipment
Solar Cell IV Testing Equipment for Steady State Solar Simulators
Solar Cell IV Testing Equipment for Flash Solar Simulators
Quantum Efficiency
Modular Spectrometers
FTIR Spectrometers
Monochromators and Spectrographs
Small Series
Standard Series
High Resolution Series
Integrated and Modular Systems
Spectroradiometer For Detector Characterization
Spectrophotometry
Fluorescence Spectroscopy
Raman Spectroscopy
LIBS Spectrometer
Far Infrared Systems (THz)
Far Infrared Spectrometers
Electrochemical Workstations
Potentiostats
Addons Cards
External Potentiostats
Probes
Multiplexers
Extension and Cell Kits
Photoelectrochemistry & Photovoltaic
Electronic Loads
Upgrades
Accessories / Parts
Cell Chucks
Data Acquisition Equipment
Other Accessories
Sample Chambers
Software
Power Supply
Calibration Cells and Power Meters
Detectors
Single Channel Detector
Line and Area Detectors
Lamps
Xenon Short Arc Lamps
Mercury Xenon Short Arc Lamp
Mercury Short Arc Lamps
QTH Lamps
Infrared Lamps
Optical Components
Bandpass Filters
Filters
Gratings
Filters for Solar Simulation
Reflectors
Optical Coupling Assemblies
Optomechanical
Integrating Spheres
Slit Assemblies
Beam Turning Units
Filter Holders
Filter Wheels
Shutter Assemblies
Optical Choppers
Adapters and Connectors
Filter By
Brands
(Clear all)
Canuck tools
CNC Kitchen
Polymaker
Sparta3D
Wuhan Precise Instrument Co., Ltd.
Yongu Electronics Machinery Technology Co., Ltd
Price Filter
$
-
$
x
Clear all
x
Filter Option
(SSIVT-REF) SSIVT Reference Detector
The Sciencetech SSIVT-REF single element silicon detector is designed to be used for monitoring and verifying the Sun level of solar simulators. The SSIVT-REF detector is used effective in sensing wavelengths between 190 nm and 1100 nm and is calibrated at Sciencetech against a NIST traceable calibrated reference cell. The SSIVT-REF detector can be used with Sciencetech SSIVT measurement system or Sciencetech SOL-METER solar power meter. Comes with a detachable cable with 4 banana plugs for connecting to a measurement device such as a source meter or Sciencetech SOL-METER. CE compliant.
Rise time: 0.2 μs
Effective active area: 5.7 sqmm
Dimensions: 50.8 x 50.8 x 25.4 mm
$
625.00
In stock
The Sciencetech SSIVT-REF single element silicon detector is designed to be used for monitoring and verifying the Sun level of solar simulators. The SSIVT-REF detector is used effective in sensing wavelengths between 190 nm and 1100 nm and is calibrated at Sciencetech against a NIST traceable calibrated reference cell. The SSIVT-REF detector can be used with Sciencetech SSIVT measurement system or Sciencetech SOL-METER solar power meter. Comes with a detachable cable with 4 banana plugs for connecting to a measurement device such as a source meter or Sciencetech SOL-METER. CE compliant.
Rise time: 0.2 μs
Effective active area: 5.7 sqmm
Dimensions: 50.8 x 50.8 x 25.4 mm
$
625.00
625.0
USD
Price Valid only in North America
(CCD-S3600-D-UV) Advanced Digital CCD Line Camera
Alphalas 3648 pixel linear CCD.
UV to IR spectral range 200 - 1100 nm, 16-bit ADC, large 32 MB of fast DDR2 onboard RAM, max. 269.5 fps, high-speed USB 2.0
Housing: 90 x 25 x 105 mm (W x H x D)
Comes with specific USB power/signal cable for interfacing to a computer.
Works with Sciencetech SciSpec Software integrating camera readout and monochromator position information. This camera is also compatible with LabView. A C++ programming library is available for this camera at extra cost.
This camera can also be triggered using TTL signals making it a perfect option for interfacing with Sciencetech's high speed shutters for decay measurements.
$
2,717.00
In stock
Alphalas 3648 pixel linear CCD.
UV to IR spectral range 200 - 1100 nm, 16-bit ADC, large 32 MB of fast DDR2 onboard RAM, max. 269.5 fps, high-speed USB 2.0
Housing: 90 x 25 x 105 mm (W x H x D)
Comes with specific USB power/signal cable for interfacing to a computer.
Works with Sciencetech SciSpec Software integrating camera readout and monochromator position information. This camera is also compatible with LabView. A C++ programming library is available for this camera at extra cost.
This camera can also be triggered using TTL signals making it a perfect option for interfacing with Sciencetech's high speed shutters for decay measurements.
$
2,717.00
2717.0
USD
Price Valid only in North America
(PMH-01-HR) Photon Counting PMT Module
The Sciencetech PMH-01 Photon Counting Module is self-contained compact unit incorporating PMT tube, high-speed amplifier, discriminator, and high voltage power supply. The output signal (train of pulses, the number of which corresponds to the number of detected photons) can be sent via a BNC connector, to an external counting/displaying circuit. The PMH-01 outputs digital signal (pulses) only. There is no analog output port.
The photon counting head used has low power consumption (max 0.5W). It is already adjusted for best S/N ratio. There is no additional adjustment necessary to start the operation.
Parameter Value
Operating Temperature Range +5 to + 40 °C
Storage Temperature Range -20 to +50 °C
Effective Area 4 x 6 sq.mm
Spectral Response 185 to 900 nm
Dark Count (Typical) 400 cps
Dark Count (Max.) 800 cps
Counting Linearity 2.5 Mcps
Pulse Pair Resolution 35 ns
Output Pulse Width 30 ns
Output Logic TTL, positive
Input Voltage +5 V
Input Current at 2.5 Mcps Output max. 80 mA
Output Signal Cable RG-174/U
$
4,000.00
In stock
The Sciencetech PMH-01 Photon Counting Module is self-contained compact unit incorporating PMT tube, high-speed amplifier, discriminator, and high voltage power supply. The output signal (train of pulses, the number of which corresponds to the number of detected photons) can be sent via a BNC connector, to an external counting/displaying circuit. The PMH-01 outputs digital signal (pulses) only. There is no analog output port.
The photon counting head used has low power consumption (max 0.5W). It is already adjusted for best S/N ratio. There is no additional adjustment necessary to start the operation.
Parameter Value
Operating Temperature Range +5 to + 40 °C
Storage Temperature Range -20 to +50 °C
Effective Area 4 x 6 sq.mm
Spectral Response 185 to 900 nm
Dark Count (Typical) 400 cps
Dark Count (Max.) 800 cps
Counting Linearity 2.5 Mcps
Pulse Pair Resolution 35 ns
Output Pulse Width 30 ns
Output Logic TTL, positive
Input Voltage +5 V
Input Current at 2.5 Mcps Output max. 80 mA
Output Signal Cable RG-174/U
$
4,000.00
4000.0
USD
Price Valid only in North America
(SOL-METER-D) Solar Reference Detector with Power Meter
This product consists of the Sciencetech SOL-METER and our SSIVT-REF sun calibrated reference detector. The SOL-METER is a digital meter for use with solar calibrated detectors such as detector models SSIVT-REF or SC-LT. The meter converts detector measurements to a Sun value. It has a handheld meter that is compact, has a sturdy design, and is appropriate for indoor or outdoor applications.
The Sciencetech Reference Detector, which is an integral part of solar simulator calibration and solar cell I-V characterization, consists of a single element silicon detector and is designed to be used for monitoring and verifying the Sun level of solar simulators. The SSIVT-REF detector is used effective in sensing wavelengths between 190 nm and 1100 nm and is calibrated at Sciencetech against a NIST traceable calibrated reference cell. Comes with a detachable cable with 4 banana plugs for connecting to a measurement device. CE compliant.
Rise time: 0.2 μs
Effective active area: 5.7 sqmm
Dimensions: 50.8 x 50.8 x 25.4 mm
$
2,800.00
In stock
This product consists of the Sciencetech SOL-METER and our SSIVT-REF sun calibrated reference detector. The SOL-METER is a digital meter for use with solar calibrated detectors such as detector models SSIVT-REF or SC-LT. The meter converts detector measurements to a Sun value. It has a handheld meter that is compact, has a sturdy design, and is appropriate for indoor or outdoor applications.
The Sciencetech Reference Detector, which is an integral part of solar simulator calibration and solar cell I-V characterization, consists of a single element silicon detector and is designed to be used for monitoring and verifying the Sun level of solar simulators. The SSIVT-REF detector is used effective in sensing wavelengths between 190 nm and 1100 nm and is calibrated at Sciencetech against a NIST traceable calibrated reference cell. Comes with a detachable cable with 4 banana plugs for connecting to a measurement device. CE compliant.
Rise time: 0.2 μs
Effective active area: 5.7 sqmm
Dimensions: 50.8 x 50.8 x 25.4 mm
$
2,800.00
2800.0
USD
Price Valid only in North America
(NIR-PMT) Near InfraRed Photomultiplier Tube System 950 - 1700nm
The NIR-PMT is contained in a thermally insulated, sealed-off housing evacuated to a high vacuum. Simple operation by air cooled TE cooler. It is a high sensitivity detector with a large detection area of 18mm for collimated light. It includes a HV power supply with interlock function.
Fast response time
Rise Time: 900 ps
TTS: 300 ps
This unit includes the housing, power supply, and detector components, but does not include mounting to a monochromator or sample chamber. Please include mounting separately.
$
44,625.00
In stock
The NIR-PMT is contained in a thermally insulated, sealed-off housing evacuated to a high vacuum. Simple operation by air cooled TE cooler. It is a high sensitivity detector with a large detection area of 18mm for collimated light. It includes a HV power supply with interlock function.
Fast response time
Rise Time: 900 ps
TTS: 300 ps
This unit includes the housing, power supply, and detector components, but does not include mounting to a monochromator or sample chamber. Please include mounting separately.
$
44,625.00
44625.0
USD
Price Valid only in North America
Mounted Silicon Photodiode, (350-1100 nm), Anode Grounded
Active Area: 13mm^2 (3.6 x 3.6mm)
Rise Time: 10ns @20V
NEP: 1.2 x 10^(-14) W/Hz^(1/2) @ 900nm, 20V
Dark Current: 20nA @ 20V
Junction capacitance: 40pF @ 10V
$
320.00
In stock
Active Area: 13mm^2 (3.6 x 3.6mm)
Rise Time: 10ns @20V
NEP: 1.2 x 10^(-14) W/Hz^(1/2) @ 900nm, 20V
Dark Current: 20nA @ 20V
Junction capacitance: 40pF @ 10V
$
320.00
320.0
USD
Price Valid only in North America
Mounted Large Area Silicon Photodiode, (350-1100 nm), Anode Grounded
Active Area: 100mm^2 (10 x 10mm)
Rise Time: 150ns
NEP: 1.5 x 10^(-14) W/Hz^(1/2) @ 960nm
Dark Current: 200pA @ 5V
Junction capacitance: 380pF @ 5V
$
320.00
In stock
Active Area: 100mm^2 (10 x 10mm)
Rise Time: 150ns
NEP: 1.5 x 10^(-14) W/Hz^(1/2) @ 960nm
Dark Current: 200pA @ 5V
Junction capacitance: 380pF @ 5V
$
320.00
320.0
USD
Price Valid only in North America
Amplified Photodetector (350-1100nm)
Material: Si
Wavelength Range: 350-1100
Detector Size: 3.6 x 3.6mm
Gain (Fixed): 8 x 10 dB steps
Bandwidth Range: DC - 17MHz
NEP: 2.1x10^(-12) to 7.7x10^(-11) W/Hz^(1/2)
$
650.00
In stock
Material: Si
Wavelength Range: 350-1100
Detector Size: 3.6 x 3.6mm
Gain (Fixed): 8 x 10 dB steps
Bandwidth Range: DC - 17MHz
NEP: 2.1x10^(-12) to 7.7x10^(-11) W/Hz^(1/2)
$
650.00
650.0
USD
Price Valid only in North America
Amplified Photodetector (350-1100nm)
Material: Si
Wavelength Range: 350-1100
Detector Size: 0.8mm diameter
Gain (Fixed): 100kV/A
Bandwidth Range: DC - 50MHz
NEP: 6.5x10^(-11) W/Hz^(1/2)
$
800.00
In stock
Material: Si
Wavelength Range: 350-1100
Detector Size: 0.8mm diameter
Gain (Fixed): 100kV/A
Bandwidth Range: DC - 50MHz
NEP: 6.5x10^(-11) W/Hz^(1/2)
$
800.00
800.0
USD
Price Valid only in North America
Amplified Si Photodetector (200-1100nm)
Material: Si
Wavelength Range: 200-1100
Detector Size: 1.0mm diameter
Gain (Fixed): 10kV/A
Bandwidth Range: DC - 150MHz
NEP: 5.5x10^(-11) W/Hz^(1/2)
$
632.00
In stock
Material: Si
Wavelength Range: 200-1100
Detector Size: 1.0mm diameter
Gain (Fixed): 10kV/A
Bandwidth Range: DC - 150MHz
NEP: 5.5x10^(-11) W/Hz^(1/2)
$
632.00
632.0
USD
Price Valid only in North America
High Speed Photodetector (350-1100nm)
Active Area: 13mm^2 (3.6 x 3.6mm)
Wavelength Range: 350-1100nm
Rise Time: 14ns
NEP: 1.6x10^(-14) W/Hz^(1/2)
Dark Current: 0.35nA
Junction Capacitance: 40pF
$
560.00
In stock
Active Area: 13mm^2 (3.6 x 3.6mm)
Wavelength Range: 350-1100nm
Rise Time: 14ns
NEP: 1.6x10^(-14) W/Hz^(1/2)
Dark Current: 0.35nA
Junction Capacitance: 40pF
$
560.00
560.0
USD
Price Valid only in North America
Mounted Si Photodiode, Cathode Grounded (350-1100nm)
Rise/Fall Time: 14 ns
Active Area: 13mm^2 (3.6 x 3.6mm)
NEP: 1.6E-14 W/Hz^(1/2)
Dark Current: 0.35 nA
Material: UV-enhanced Si
Junction Capacitance: 40pF @5V
$
360.00
In stock
Rise/Fall Time: 14 ns
Active Area: 13mm^2 (3.6 x 3.6mm)
NEP: 1.6E-14 W/Hz^(1/2)
Dark Current: 0.35 nA
Material: UV-enhanced Si
Junction Capacitance: 40pF @5V
$
360.00
360.0
USD
Price Valid only in North America
UV-enhanced Si Mounted Photodiode, Cathode Grounded (200-1100nm)
Rise/Fall Time: 450ns/45ns
Responsivity: 0.50 A/W
Active Area: Diameter = 9mm
NEP: 5.5E-14 W/Hz^(1/2)@5V
Dark Current: 1.0uA@5V
Material: UV-enhanced Si
Junction Capacitance: 1.75nF @0V
$
620.00
Rise/Fall Time: 450ns/45ns
Responsivity: 0.50 A/W
Active Area: Diameter = 9mm
NEP: 5.5E-14 W/Hz^(1/2)@5V
Dark Current: 1.0uA@5V
Material: UV-enhanced Si
Junction Capacitance: 1.75nF @0V
$
620.00
620.0
USD
Price Valid only in North America
Mounted Photodiode, Cathode Grounded (350-1100nm)
Rise/Fall Time: 10ns
Active Area: 13mm^2 (3.6x3.6mm)
NEP: 1.2x10^(-14) W/Hz^(1/2)
Dark Current: 0.3nA
Material: Si
Junction Capacitance: 65pF @5V
$
360.00
In stock
Rise/Fall Time: 10ns
Active Area: 13mm^2 (3.6x3.6mm)
NEP: 1.2x10^(-14) W/Hz^(1/2)
Dark Current: 0.3nA
Material: Si
Junction Capacitance: 65pF @5V
$
360.00
360.0
USD
Price Valid only in North America
Mounted UV-Enhanced Si Photodiode, Cathode Grounded (200-1100nm)
Rise/Fall Time: 45ns
Active Area: 100mm^2 (Diameter = 11.0mm)
NEP: 5.5x10^(-14) W/Hz^(1/2)
Dark Current: 1.0uA
Material: Si
Junction Capacitance: 1.75nF @0V
$
290.00
In stock
Rise/Fall Time: 45ns
Active Area: 100mm^2 (Diameter = 11.0mm)
NEP: 5.5x10^(-14) W/Hz^(1/2)
Dark Current: 1.0uA
Material: Si
Junction Capacitance: 1.75nF @0V
$
290.00
290.0
USD
Price Valid only in North America
Liquid Helium Cooled Bolometer (1.6K Version)
Liquid Helium Cooled Bolometers are 10^2 to 10^4 (two to four orders magnitude) more sensitive than room temperature pyro-electric detectors
Liquid Helium Cooled 1.6K
5u - 2000u spectral range
Liquid Nitrogen required in outer jacket (dual stage cooling)
2.5 mm diameter diamond absorber
0.5" F/3.8 diameter condensing cone as input optics
Preamp circuitry generates +/-14V max
5" Diameter Dewar Included
Filterwheel Position #1 - Long pass 5micron cut-on
Position #2 - Wedged P13 filter (13micron cut-on long pass)
Position #3 - Wedged C103 filter (103 micron cut-on long pass filter)
Wedged Diamond window Diameter = 25.0mm
$
54,340.00
In stock
Liquid Helium Cooled Bolometers are 10^2 to 10^4 (two to four orders magnitude) more sensitive than room temperature pyro-electric detectors
Liquid Helium Cooled 1.6K
5u - 2000u spectral range
Liquid Nitrogen required in outer jacket (dual stage cooling)
2.5 mm diameter diamond absorber
0.5" F/3.8 diameter condensing cone as input optics
Preamp circuitry generates +/-14V max
5" Diameter Dewar Included
Filterwheel Position #1 - Long pass 5micron cut-on
Position #2 - Wedged P13 filter (13micron cut-on long pass)
Position #3 - Wedged C103 filter (103 micron cut-on long pass filter)
Wedged Diamond window Diameter = 25.0mm
$
54,340.00
54340.0
USD
Price Valid only in North America
Liquid Helium Cooled Bolometer (4.2K Version)
Liquid Helium Cooled Bolometers are 10^2 to 10^4 (two to four orders of magnitude) more sensitive than room temperature pyro-electric detectors
Liquid Helium Cooled to 4.2K
Liquid Nitrogen required in outer jacket (dual stage cooling)
Response for 20~100um, with some sensitivity up to 300um
0.5" diameter condensing cone as input optics
Preamp circuitry generates +/-14V max
5" Diameter Dewar Included
See below for more specifications.
Contact for Pricing
Liquid Helium Cooled Bolometers are 10^2 to 10^4 (two to four orders of magnitude) more sensitive than room temperature pyro-electric detectors
Liquid Helium Cooled to 4.2K
Liquid Nitrogen required in outer jacket (dual stage cooling)
Response for 20~100um, with some sensitivity up to 300um
0.5" diameter condensing cone as input optics
Preamp circuitry generates +/-14V max
5" Diameter Dewar Included
See below for more specifications.
$
34,340.00
34340.0
USD
Price Valid only in North America
(BBT-3000) Detector, 4kW Power, Water Cooled, 100mm Aperture
4kW max average power, 100mm aperture, water-cooled. Doesn't require monitor, includes USB cable and PC-HP application software.
Sensitivity 0.4 mW/W,
rise time 7 sec,
spectral range 0.19-20um.
$
7,911.00
In stock
4kW max average power, 100mm aperture, water-cooled. Doesn't require monitor, includes USB cable and PC-HP application software.
Sensitivity 0.4 mW/W,
rise time 7 sec,
spectral range 0.19-20um.
$
7,911.00
7911.0
USD
Price Valid only in North America
(MCT-10-010-E-LN) Detector - MCT Cryogenic Receiver, LN2 cooled - 1x1mm
Element Size: 1mm x 1mm sq.
Operating Wavelength: 2 – 13um
Wavelength Peak: ~12.0um
Wavelength Response: >= 13.0um (750cm-1)
D* (λp,10000,1) (cmHz1/2W-1): >= 4.0^10
Dewar Hold Time: 12 hours minimum with liquid N2
FoV/Window: 60 degrees/ ZnSe
Responsivity: >= 2000 (pk. (V/W))
Resistance: 20-100 ohms
Time Constant: ~1.0 usec
MSL-8 side looking metal Dewar 8 hour hold time
$
2,935.00
In stock
Element Size: 1mm x 1mm sq.
Operating Wavelength: 2 – 13um
Wavelength Peak: ~12.0um
Wavelength Response: >= 13.0um (750cm-1)
D* (λp,10000,1) (cmHz1/2W-1): >= 4.0^10
Dewar Hold Time: 12 hours minimum with liquid N2
FoV/Window: 60 degrees/ ZnSe
Responsivity: >= 2000 (pk. (V/W))
Resistance: 20-100 ohms
Time Constant: ~1.0 usec
MSL-8 side looking metal Dewar 8 hour hold time
$
2,935.00
2935.0
USD
Price Valid only in North America
SPS-300 DTGS Detector
This is a room-temperature detector for use with the SPS-300. This includes the DTGS detector with a mounting flange, but requires the use of a dual-phase lock-in amplifier (sold separately). Sciencetech's wideband detector design comes packaged in a mounting flange compatible with our SPS-300. It is connectorized to be powered directly from the Stanford SR-810/830 type lock-in amplifiers with a detachable cable. The spectral range is limited by window selection. This detector comes with a HDPE window standard.
Element size: 2.0 mm dia.
Spectral bandwidth: 16 to 100um (for HDPE window, other window materials available)
Sensitivity: 200 V/W
Frequency response: 10Hz - 265Hz (-3db points)
N.E.P.: 5x10-10 watts (@100Hz)
Power requirements: +/- 15 to +/- 24 volts max @ +/- 8 mA max.
Power connections:
DB-9M
Pins 2,3,4,5,9 no connection
+V In Pin 1
-V In Pin 6
Common Pin 7
Case GND Pin 8
Signal Connection: BNC
Suitable for direct connection to Stanford SR-810/830 lockin preamp power (not included).
This is a room-temperature detector for use with the SPS-300. This includes the DTGS detector with a mounting flange, but requires the use of a dual-phase lock-in amplifier (sold separately).
$
7,200.00
This is a room-temperature detector for use with the SPS-300. This includes the DTGS detector with a mounting flange, but requires the use of a dual-phase lock-in amplifier (sold separately). Sciencetech's wideband detector design comes packaged in a mounting flange compatible with our SPS-300. It is connectorized to be powered directly from the Stanford SR-810/830 type lock-in amplifiers with a detachable cable. The spectral range is limited by window selection. This detector comes with a HDPE window standard.
Element size: 2.0 mm dia.
Spectral bandwidth: 16 to 100um (for HDPE window, other window materials available)
Sensitivity: 200 V/W
Frequency response: 10Hz - 265Hz (-3db points)
N.E.P.: 5x10-10 watts (@100Hz)
Power requirements: +/- 15 to +/- 24 volts max @ +/- 8 mA max.
Power connections:
DB-9M
Pins 2,3,4,5,9 no connection
+V In Pin 1
-V In Pin 6
Common Pin 7
Case GND Pin 8
Signal Connection: BNC
Suitable for direct connection to Stanford SR-810/830 lockin preamp power (not included).
This is a room-temperature detector for use with the SPS-300. This includes the DTGS detector with a mounting flange, but requires the use of a dual-phase lock-in amplifier (sold separately).
$
7,200.00
7200.0
USD
Price Valid only in North America