Calibration Cells and Power Meters

X

Product Category

View Filter

x
Clear all x

Filter Option



The Sciencetech SSIVT-REF single element silicon detector is designed to be used for monitoring and verifying the Sun level of solar simulators. The SSIVT-REF detector is used effective in sensing wavelengths between 190 nm and 1100 nm and is calibrated at Sciencetech against a NIST traceable calibrated reference cell. The SSIVT-REF detector can be used with Sciencetech SSIVT measurement system or Sciencetech SOL-METER solar power meter. Comes with a detachable cable with 4 banana plugs for connecting to a measurement device such as a source meter or Sciencetech SOL-METER. CE compliant.

Rise time: 0.2 μs
Effective active area: 5.7 sq. mm
Dimensions: 50.8 × 50.8 × 25.4 mm
625.00
In Stock
The Sciencetech SSIVT-REF single element silicon detector is designed to be used for monitoring and verifying the Sun level of solar simulators. The SSIVT-REF detector is used effective in sensing wavelengths between 190 nm and 1100 nm and is calibrated at Sciencetech against a NIST traceable calibrated reference cell. The SSIVT-REF detector can be used with Sciencetech SSIVT measurement system or Sciencetech SOL-METER solar power meter. Comes with a detachable cable with 4 banana plugs for connecting to a measurement device such as a source meter or Sciencetech SOL-METER. CE compliant.

Rise time: 0.2 μs
Effective active area: 5.7 sq. mm
Dimensions: 50.8 × 50.8 × 25.4 mm
625.00 625.0 USD
Price Valid only in North America


The SCI-MO reference cell is a robust PCB-mounted solar cell with an active area of 22 × 7mm. The SCI-MO is intended to be used as a reference monitor for determining solar simulator sun level. These reference cells are calibrated for 1 Sun AM1.5G using a Sciencetech Class AAA (ASTM E927-19) solar simulator. Two calibration values (Isc) in mA/Sun and mV/Sun are provided. The SCI-MO is used as the reference cell in PTS-series instruments.

Readout options for the SCI-MO require accessories. They are:
Current (in mA): in no load mode, requires a source meter (such as in SSIVT-series current-voltage measurement systems) to read out.
Voltage (in mV): in loaded mode, requires a simple voltmeter/multimeter (such as MULTIMETER), or a source meter (such as in SSIVT-series current-voltage measurement systems) to read out.
Suns: in no load mode, requires SOL-METER to read out (using current, an integrated load resistor, and a pre-loaded calibration value to display Suns).

Readout accessories, such as SOL-METER, MULTIMETER, and SSIVT-series instruments are sold separately.

The reference cell can be switched into loaded or unloaded mode via a surface mounted switch on the top of the detector PCB. A calibration value is provided for each mode of operation.
A disconnectable 1.2m long cable assembly with 4 color coded banana plugs is provided with each device.

The SCI-MO reference cell is RoHS compliant.
379.00
The SCI-MO reference cell is a robust PCB-mounted solar cell with an active area of 22 × 7mm. The SCI-MO is intended to be used as a reference monitor for determining solar simulator sun level. These reference cells are calibrated for 1 Sun AM1.5G using a Sciencetech Class AAA (ASTM E927-19) solar simulator. Two calibration values (Isc) in mA/Sun and mV/Sun are provided. The SCI-MO is used as the reference cell in PTS-series instruments.

Readout options for the SCI-MO require accessories. They are:
Current (in mA): in no load mode, requires a source meter (such as in SSIVT-series current-voltage measurement systems) to read out.
Voltage (in mV): in loaded mode, requires a simple voltmeter/multimeter (such as MULTIMETER), or a source meter (such as in SSIVT-series current-voltage measurement systems) to read out.
Suns: in no load mode, requires SOL-METER to read out (using current, an integrated load resistor, and a pre-loaded calibration value to display Suns).

Readout accessories, such as SOL-METER, MULTIMETER, and SSIVT-series instruments are sold separately.

The reference cell can be switched into loaded or unloaded mode via a surface mounted switch on the top of the detector PCB. A calibration value is provided for each mode of operation.
A disconnectable 1.2m long cable assembly with 4 color coded banana plugs is provided with each device.

The SCI-MO reference cell is RoHS compliant.
379.00 379.0 USD
Price Valid only in North America


This product consists of the Sciencetech SOL-METER and our SSIVT-REF sun calibrated reference detector. The SOL-METER is a digital meter for use with solar calibrated detectors such as detector models SSIVT-REF or SC-LT. The meter converts detector measurements to a Sun value. It has a handheld meter that is compact, has a sturdy design, and is appropriate for indoor or outdoor applications.

The Sciencetech Reference Detector, which is an integral part of solar simulator calibration and solar cell I-V characterization, consists of a single element silicon detector and is designed to be used for monitoring and verifying the Sun level of solar simulators. The SSIVT-REF detector is used effective in sensing wavelengths between 190 nm and 1100 nm and is calibrated at Sciencetech against a NIST traceable calibrated reference cell. Comes with a detachable cable with 4 banana plugs for connecting to a measurement device. CE compliant.

Rise time: 0.2 μs
Effective active area: 5.7 sqmm
Dimensions: 50.8 x 50.8 x 25.4 mm
2,800.00
In Stock
This product consists of the Sciencetech SOL-METER and our SSIVT-REF sun calibrated reference detector. The SOL-METER is a digital meter for use with solar calibrated detectors such as detector models SSIVT-REF or SC-LT. The meter converts detector measurements to a Sun value. It has a handheld meter that is compact, has a sturdy design, and is appropriate for indoor or outdoor applications.

The Sciencetech Reference Detector, which is an integral part of solar simulator calibration and solar cell I-V characterization, consists of a single element silicon detector and is designed to be used for monitoring and verifying the Sun level of solar simulators. The SSIVT-REF detector is used effective in sensing wavelengths between 190 nm and 1100 nm and is calibrated at Sciencetech against a NIST traceable calibrated reference cell. Comes with a detachable cable with 4 banana plugs for connecting to a measurement device. CE compliant.

Rise time: 0.2 μs
Effective active area: 5.7 sqmm
Dimensions: 50.8 x 50.8 x 25.4 mm
2,800.00 2800.0 USD
Price Valid only in North America
Copyright © Sciencetech