Products | Sciencetech Inc.
Sciencetech has a large selection of "stand alone" and "open architecture" off-the-shelf and custom made products for researchers using spectroscopy or working with photovoltaics. We offer technical staff to help with the development of custom systems for special applications. Since 1985, Sciencetech has manufactured Modular Instrumentation for Spectroscopy, TeraHertz FTIRs, Highly Collimated Large Solar Simulators, Flash and Continuous Solar Simulators, Photovoltaic Instrumentation, Quantum Efficiency and Spectral Response Systems, Spectrophotometers/radiometers, Monochromators, Detection Systems, and Light Sources to offer to the global research community through a network of representatives.

 here

Sciencetech product design

SCIENCETECH has built a reputation on custom solutions. Whether you need a small modification to an existing system or a completely novel design built from the ground up to meet your technical specifications, Sciencetech's engineering and optical design teams are ready to help.

SCIENCETECH prides itself on our ability to build custom solutions and systems to the most exacting of specifications. Whether you need higher sensitivity, better throughput, more power, better spectral matching, higher resolution, or any other variable modified to give you exactly what you need, our team of engineers, physicists, and optical designers stand ready to provide you with a solution that will meet your technical requirements.

SCIENCETECH'S SOLAR SIMULATORS IN ACTION - The European Commission just released an article involving the use of Sciencetech's solar simulators in their new facility. Read the full article HERE.

X

Product Category

View Filter

x
Clear all x

Filter Option



This four slot filter-wheel was originally designed for the US military to work in a 10^(-7) Torr vacuum environment. Today, a standard non-vacuum version and the original vacuum version are available. The vacuum version can be manufactured in a Class 10,000 clean room, fully baked out, and meets Class A cleanliness standards, at a small additional cost. Please note that the optional external control electronics is not designed to operate in a vacuum. It must operate in ambient pressure environment.
5,127.00
In stock
This four slot filter-wheel was originally designed for the US military to work in a 10^(-7) Torr vacuum environment. Today, a standard non-vacuum version and the original vacuum version are available. The vacuum version can be manufactured in a Class 10,000 clean room, fully baked out, and meets Class A cleanliness standards, at a small additional cost. Please note that the optional external control electronics is not designed to operate in a vacuum. It must operate in ambient pressure environment.
5,127.00 5127.0 USD
Price Valid only in North America


This hot mirror filters out IR light to remove thermal heat on the target. However, standard hot mirrors also remove UV light as a side-effect which mean it cannot be used in UV applications. This special hot mirror removes IR light between 730-1100nm while preserving UVA and UVB light (280-400nm) in addition to visible light. This filter is ideal for Sciencetech UV solar simulators where the filtering of thermal heat on the target is desired and preservation of UVA and UVB light is required.FT
This filter is intended for use at 0 degree angle of incidence.

This filter is mounted in Sciencetech FT style filter mount with a 76.2mm diameter clear aperture.

Please note this filter does not eliminate all thermal heat in the IR range as this filter stops at 1,100nm. Hence IR heat beyond 1,100nm still pass through. To remove more IR light see Sciencetech's range of IR water filters or contact a Sciencetech application scientist to learn about other options.
600.00
In stock
This hot mirror filters out IR light to remove thermal heat on the target. However, standard hot mirrors also remove UV light as a side-effect which mean it cannot be used in UV applications. This special hot mirror removes IR light between 730-1100nm while preserving UVA and UVB light (280-400nm) in addition to visible light. This filter is ideal for Sciencetech UV solar simulators where the filtering of thermal heat on the target is desired and preservation of UVA and UVB light is required.FT
This filter is intended for use at 0 degree angle of incidence.

This filter is mounted in Sciencetech FT style filter mount with a 76.2mm diameter clear aperture.

Please note this filter does not eliminate all thermal heat in the IR range as this filter stops at 1,100nm. Hence IR heat beyond 1,100nm still pass through. To remove more IR light see Sciencetech's range of IR water filters or contact a Sciencetech application scientist to learn about other options.
600.00 600.0 USD
Price Valid only in North America


An AM1.5D 3x3" air mass filter (including filter holder) designed for Sciencetech's:
-Flash Series Solar Simulators (Class A, ASTM E927-19)

AM1.5D simulates the terrestrial solar spectrum on the ground when the sun is at a zenith angle of 48.2°. It includes only direct light from the sun, and not the diffuse light that is scattered by the atmosphere. As a result, this filter simulates the direct radiation which reaches the ground.
4,133.00
In stock
An AM1.5D 3x3" air mass filter (including filter holder) designed for Sciencetech's:
-Flash Series Solar Simulators (Class A, ASTM E927-19)

AM1.5D simulates the terrestrial solar spectrum on the ground when the sun is at a zenith angle of 48.2°. It includes only direct light from the sun, and not the diffuse light that is scattered by the atmosphere. As a result, this filter simulates the direct radiation which reaches the ground.
4,133.00 4133.0 USD
Price Valid only in North America


Sciencetech's 120-9045 high speed shutter is a recommended accessory with Sciencetech's area scan CCD detectors, but can also be used with Sciencetech's LDA photodiodes or InGaAs linear array detectors. This shutter mounts inside a Sciencetech spectrograph behind the input port. Due to its sturdy steel construction, it can withstand approximately 5W/mm^2 (up to about 200 degrees Celsius). This product includes both the shutter and the controller, and can be either manually controlled (via externally mounted button) or computer controlled.
2,200.00
In stock
Sciencetech's 120-9045 high speed shutter is a recommended accessory with Sciencetech's area scan CCD detectors, but can also be used with Sciencetech's LDA photodiodes or InGaAs linear array detectors. This shutter mounts inside a Sciencetech spectrograph behind the input port. Due to its sturdy steel construction, it can withstand approximately 5W/mm^2 (up to about 200 degrees Celsius). This product includes both the shutter and the controller, and can be either manually controlled (via externally mounted button) or computer controlled.
2,200.00 2200.0 USD
Price Valid only in North America


A longpass filter has low transmission in the shortwave region (stopped) and high transmission in the longwave range (passband).
Size: 2" diameter
Material thickness: 3 mm
Surface Quality: 80-50
This filter includes the holder required to mount into Sciencetech's line of filter holders. For mounting into other applications, please speak with your authorized Sciencetech technical sales staff member.
360.00
In stock
A longpass filter has low transmission in the shortwave region (stopped) and high transmission in the longwave range (passband).
Size: 2" diameter
Material thickness: 3 mm
Surface Quality: 80-50
This filter includes the holder required to mount into Sciencetech's line of filter holders. For mounting into other applications, please speak with your authorized Sciencetech technical sales staff member.
360.00 360.0 USD
Price Valid only in North America


The CTBT-RF is designed to work with Sciencetech's line of SS solar simulators (between 500W and 2.5kW). The CTBT-RF is designed to hold 3" x 4" cold mirrors. A heat sink is mounted behind the dichroic turning mirror to capture transmitted light. The CTBT-RF turns the beam 90 degrees from the standard horizontal output.


Four different cold mirror options exist (purchased separately):
1) 275-375nm
2) 325-450nm
3) 350-550nm
4) 450-725nm
5) UV Enhanced aluminum mirror (250-3000nm)


Please speak with your Sciencetech representative for ordering information.
1,350.00
In stock
The CTBT-RF is designed to work with Sciencetech's line of SS solar simulators (between 500W and 2.5kW). The CTBT-RF is designed to hold 3" x 4" cold mirrors. A heat sink is mounted behind the dichroic turning mirror to capture transmitted light. The CTBT-RF turns the beam 90 degrees from the standard horizontal output.


Four different cold mirror options exist (purchased separately):
1) 275-375nm
2) 325-450nm
3) 350-550nm
4) 450-725nm
5) UV Enhanced aluminum mirror (250-3000nm)


Please speak with your Sciencetech representative for ordering information.
1,350.00 1350.0 USD
Price Valid only in North America


This filter is mounted in Sciencetech FT style filter mount with a 76.2mm diameter clear aperture.

Visible band block, UV pass filter
Clear aperture 3" diameter
Pass band 280-390nm
Blocking 420-750nm
Interference filter
Angle of incidence = 0 deg

2,000.00
In stock
This filter is mounted in Sciencetech FT style filter mount with a 76.2mm diameter clear aperture.

Visible band block, UV pass filter
Clear aperture 3" diameter
Pass band 280-390nm
Blocking 420-750nm
Interference filter
Angle of incidence = 0 deg

2,000.00 2000.0 USD
Price Valid only in North America


The TEO-402 is a compact Michelson interferometer module with built-in laser and a broadband IR source. It is designed to be used as a core component in a complete FTIR instrument.
Note that this system does not include a power supply, AD board, or detector.
10,238.00
In stock
The TEO-402 is a compact Michelson interferometer module with built-in laser and a broadband IR source. It is designed to be used as a core component in a complete FTIR instrument.
Note that this system does not include a power supply, AD board, or detector.
10,238.00 10238.0 USD
Price Valid only in North America


An arc lamp is not designed to be frequently turned off and on and doing so will dramatically lower its service life. In addition, each time it is turned on it requires the power supply to ignite it with a 20,000V+ spark. The best option for performing exposure testing is to integrate an electronic shutter system inside the beam homogenizer. The electronic shutter is computer controlled with an activation time of <150ms. Software for the shutter controller is included with this item. The standard shutter controller connects to a computer via RS232. RS232-USB converters are available and work with this product. In addition to computer control, the shutter can be controlled via an interface on the power supply.

This shutter can be used with any mid-ranged powered light source and can effectivley block a 3" diameter beam. See the brochure information for a mounting pattern.

The shutter can also be controlled through Sciencetech's touch screen power supplies, including automated opening and closing of the shutter as well as preprogrammed exposure times. Ask your authorized Sciencetech technical sales staff member if you are uncertain whether your system includes one of our new power supplies.

Please note that leaving the shutter closed for extremely long periods of time while the arc lamp is on may cause damage to the motorized components.
1,756.00
In stock
An arc lamp is not designed to be frequently turned off and on and doing so will dramatically lower its service life. In addition, each time it is turned on it requires the power supply to ignite it with a 20,000V+ spark. The best option for performing exposure testing is to integrate an electronic shutter system inside the beam homogenizer. The electronic shutter is computer controlled with an activation time of <150ms. Software for the shutter controller is included with this item. The standard shutter controller connects to a computer via RS232. RS232-USB converters are available and work with this product. In addition to computer control, the shutter can be controlled via an interface on the power supply.

This shutter can be used with any mid-ranged powered light source and can effectivley block a 3" diameter beam. See the brochure information for a mounting pattern.

The shutter can also be controlled through Sciencetech's touch screen power supplies, including automated opening and closing of the shutter as well as preprogrammed exposure times. Ask your authorized Sciencetech technical sales staff member if you are uncertain whether your system includes one of our new power supplies.

Please note that leaving the shutter closed for extremely long periods of time while the arc lamp is on may cause damage to the motorized components.
1,756.00 1756.0 USD
Price Valid only in North America


The Sciencetech 9057F is a fast half meter motorized Czerny-Turner monochromator (and spectrograph) with an f/5.9 aperture. This is a "faster" model with larger optics for higher light throughput compared to the standard 9057 with f/8 aperture. Both models utilize a computer controlled motorized turret for automatic grating and wavelength selection. The regular 9057 model supports up to three 50 x 50mm gratings whereas the larger optics 9057F model supports up to two 64 x 64mm (clear aperture) gratings.
Please refer to the technical datasheet for more specifications.
8,562.00
In stock
The Sciencetech 9057F is a fast half meter motorized Czerny-Turner monochromator (and spectrograph) with an f/5.9 aperture. This is a "faster" model with larger optics for higher light throughput compared to the standard 9057 with f/8 aperture. Both models utilize a computer controlled motorized turret for automatic grating and wavelength selection. The regular 9057 model supports up to three 50 x 50mm gratings whereas the larger optics 9057F model supports up to two 64 x 64mm (clear aperture) gratings.
Please refer to the technical datasheet for more specifications.
8,562.00 8562.0 USD
Price Valid only in North America


The Dual Deuterium and Quartz Tungsten Halogen Light Source consists of a separate 30W deuterium light source and a 50W QTH light source in one optical assembly. The deuterium source and the QTH source operate simultaneously and a cold mirror is used to combine the 2 beams into a single beam.

The system has a 1" output (with the combined light) with Fused Silica lenses.
This product includes two stabilized power supplies (to operate the two bulbs), UV to IR transmissive optics, the housing itself and reflective/refractive optics for UV to IR transmission
15,000.00
In stock
The Dual Deuterium and Quartz Tungsten Halogen Light Source consists of a separate 30W deuterium light source and a 50W QTH light source in one optical assembly. The deuterium source and the QTH source operate simultaneously and a cold mirror is used to combine the 2 beams into a single beam.

The system has a 1" output (with the combined light) with Fused Silica lenses.
This product includes two stabilized power supplies (to operate the two bulbs), UV to IR transmissive optics, the housing itself and reflective/refractive optics for UV to IR transmission
15,000.00 15000.0 USD
Price Valid only in North America


Sciencetech’s high powered fully reflective solar simulators can be used for UV applications by replacing the solar filters with UV filters. The smallest model of our standard line is the 500W system, allowing the researcher on a budget the ability to get high UV solar radiation. Sciencetech's proprietary Fully Reflective design allows the system to get far more UV power on target than our competitor's systems of equal size.

Please note that the wavelength definition of UVA and UVB in the COLIPA sun screen testing community is slightly different from the general scientific community.
This solar simulator includes testing and filters to verify the system meets COLIPA and USFDA spectral requirements.
Please discuss your specific spectral needs with your authorized Sciencetech technical sales staff.
26,975.00
Sciencetech’s high powered fully reflective solar simulators can be used for UV applications by replacing the solar filters with UV filters. The smallest model of our standard line is the 500W system, allowing the researcher on a budget the ability to get high UV solar radiation. Sciencetech's proprietary Fully Reflective design allows the system to get far more UV power on target than our competitor's systems of equal size.

Please note that the wavelength definition of UVA and UVB in the COLIPA sun screen testing community is slightly different from the general scientific community.
This solar simulator includes testing and filters to verify the system meets COLIPA and USFDA spectral requirements.
Please discuss your specific spectral needs with your authorized Sciencetech technical sales staff.
26,975.00 26975.0 USD
Price Valid only in North America


The TEO-402 is a compact Michelson interferometer module with built-in laser and a broadband IR source. It is designed to be used as a core component in a complete FTIR instrument.
Note that this system does not include a power supply, AD board, or detector.
11,288.00
In stock
The TEO-402 is a compact Michelson interferometer module with built-in laser and a broadband IR source. It is designed to be used as a core component in a complete FTIR instrument.
Note that this system does not include a power supply, AD board, or detector.
11,288.00 11288.0 USD
Price Valid only in North America


9055-DX is a motorized double 1/4m monochromator that can be configured as additive or subtractive. Double monochromators have the advantage of extremely low stray light levels by virtue of using two gratings. An intermediate slit between the two units, used to define the wavelengths that pass to the second unit, also masks off light scattered within the body of the first unit. In double additive operation the 9055DX effective focal length (1/2m), dispersion and resolution (1.7nm/mm and .09nm with a 1200 l/mm grating) are doubled compared to a single unit, making this mode useful where high resolution is important. In double subtractive operation there is no dispersion in the output beam and only a single slit image appears at the output instead of a broad spread of spectral images. This allows the system to operate as a tunable bandpass or notch filter.
This system includes two manual slits (one input and one intermediate). Motorized upgrades and additional slits may be purchased separately.
Gratings also need to be purchased separately, with a minimum of 2 gratings required for the system to operate. Please speak with your Sciencetech technical sales member to ensure proper grating selection.
Please see the technical datasheet for additional information.

This system includes 2 IEC 60320 C13 compatible power cables. Region-specific version must be selected at the time of placing an order (see product 491-9001).
17,710.00
In stock
9055-DX is a motorized double 1/4m monochromator that can be configured as additive or subtractive. Double monochromators have the advantage of extremely low stray light levels by virtue of using two gratings. An intermediate slit between the two units, used to define the wavelengths that pass to the second unit, also masks off light scattered within the body of the first unit. In double additive operation the 9055DX effective focal length (1/2m), dispersion and resolution (1.7nm/mm and .09nm with a 1200 l/mm grating) are doubled compared to a single unit, making this mode useful where high resolution is important. In double subtractive operation there is no dispersion in the output beam and only a single slit image appears at the output instead of a broad spread of spectral images. This allows the system to operate as a tunable bandpass or notch filter.
This system includes two manual slits (one input and one intermediate). Motorized upgrades and additional slits may be purchased separately.
Gratings also need to be purchased separately, with a minimum of 2 gratings required for the system to operate. Please speak with your Sciencetech technical sales member to ensure proper grating selection.
Please see the technical datasheet for additional information.

This system includes 2 IEC 60320 C13 compatible power cables. Region-specific version must be selected at the time of placing an order (see product 491-9001).
17,710.00 17710.0 USD
Price Valid only in North America


Sciencetech’s high powered fully reflective solar simulators can be used for UV applications by replacing the solar filters with UV filters. Sciencetech's proprietary Fully Reflective design allows the system to get far more UV power on target than our competitor's systems of equal size.

Please note that the wavelength definition of UVA and UVB in the COLIPA sun screen testing community is slightly different from the general scientific community.
This solar simulator includes testing and filters to verify the system meets COLIPA and USFDA spectral requirements.
Please discuss your specific spectral needs with your authorized Sciencetech technical sales staff.
30,024.00
Sciencetech’s high powered fully reflective solar simulators can be used for UV applications by replacing the solar filters with UV filters. Sciencetech's proprietary Fully Reflective design allows the system to get far more UV power on target than our competitor's systems of equal size.

Please note that the wavelength definition of UVA and UVB in the COLIPA sun screen testing community is slightly different from the general scientific community.
This solar simulator includes testing and filters to verify the system meets COLIPA and USFDA spectral requirements.
Please discuss your specific spectral needs with your authorized Sciencetech technical sales staff.
30,024.00 30024.0 USD
Price Valid only in North America


The 9150 is Sciencetech's largest monochromator with a 1.5m focal length. Under optimum conditions with a 2400 l/mm grating it can achieve a resolution of 0.004 nm in single pass mode. 9150SD includes an optical module that allows the unit to be configured in a double pass mode as well, effectively doubling the focal length to 3m and achievable resolution to 0.002 nm. It utilizes large 102 x 102 mm gratings for high light throughput (f/12 aperture). The 9150SD accommodates one grating on a removable, kinematic mount that allows the user to manually swap one grating for another without losing alignment.
For additional information, please see the technical datasheet.

73,518.00
In stock
The 9150 is Sciencetech's largest monochromator with a 1.5m focal length. Under optimum conditions with a 2400 l/mm grating it can achieve a resolution of 0.004 nm in single pass mode. 9150SD includes an optical module that allows the unit to be configured in a double pass mode as well, effectively doubling the focal length to 3m and achievable resolution to 0.002 nm. It utilizes large 102 x 102 mm gratings for high light throughput (f/12 aperture). The 9150SD accommodates one grating on a removable, kinematic mount that allows the user to manually swap one grating for another without losing alignment.
For additional information, please see the technical datasheet.

73,518.00 73518.0 USD
Price Valid only in North America


The 9040DS is a Double Subtractive design of the half meter 9040. Special care has been taken to design the system to minimize and eliminate stray light whenever possible.
A double subtractive monochromator operates to create a monochromatic light source by the 2nd monochromator cancelling the dispersion caused by the 1st monochromator. This allows a Double Subtractive system to operate as a tunable notch filter for Raman applications.
Please see the technical datasheet for additional information.

This monochromator is not configurable for double pass mode.
31,150.00
In stock
The 9040DS is a Double Subtractive design of the half meter 9040. Special care has been taken to design the system to minimize and eliminate stray light whenever possible.
A double subtractive monochromator operates to create a monochromatic light source by the 2nd monochromator cancelling the dispersion caused by the 1st monochromator. This allows a Double Subtractive system to operate as a tunable notch filter for Raman applications.
Please see the technical datasheet for additional information.

This monochromator is not configurable for double pass mode.
31,150.00 31150.0 USD
Price Valid only in North America


This bandpass filter has a transmission band surrounded by two blocking bands that allow only the UV part of the spectrum to pass.
This product includes the filter and a frame for mounting in a standard Sciencetech filter box.
302.00
In stock
This bandpass filter has a transmission band surrounded by two blocking bands that allow only the UV part of the spectrum to pass.
This product includes the filter and a frame for mounting in a standard Sciencetech filter box.
302.00 302.0 USD
Price Valid only in North America


The Dual Deuterium and Quartz Tungsten Halogen Light Source consists of a separate 30W deuterium light source and a 50W QTH light source in one optical assembly. The deuterium source and the QTH source operate simultaneously and a cold mirror is used to combine the 2 beams into a single beam.

The system has a 1" output (with the combined light) with Fused Silica lenses.
This product includes two stabilized power supplies (to operate the two bulbs), UV to IR transmissive optics, the housing itself and reflective/refractive optics for UV to IR transmission
15,000.00
In stock
The Dual Deuterium and Quartz Tungsten Halogen Light Source consists of a separate 30W deuterium light source and a 50W QTH light source in one optical assembly. The deuterium source and the QTH source operate simultaneously and a cold mirror is used to combine the 2 beams into a single beam.

The system has a 1" output (with the combined light) with Fused Silica lenses.
This product includes two stabilized power supplies (to operate the two bulbs), UV to IR transmissive optics, the housing itself and reflective/refractive optics for UV to IR transmission
15,000.00 15000.0 USD
Price Valid only in North America


IR broad band pass filter, operating in approximately 2.5um to 5.0um.
This price includes the filter only; it does not include a holder, which must be purchased separately.

1,150.00
In stock
IR broad band pass filter, operating in approximately 2.5um to 5.0um.
This price includes the filter only; it does not include a holder, which must be purchased separately.

1,150.00 1150.0 USD
Price Valid only in North America
Copyright © Sciencetech
Contact Us