Products | Sciencetech Inc.
Sciencetech has a large selection of "stand alone" and "open architecture" off-the-shelf and custom made products for researchers using spectroscopy or working with photovoltaics. We offer technical staff to help with the development of custom systems for special applications. Since 1985, Sciencetech has manufactured Modular Instrumentation for Spectroscopy, TeraHertz FTIRs, Highly Collimated Large Solar Simulators, Flash and Continuous Solar Simulators, Photovoltaic Instrumentation, Quantum Efficiency and Spectral Response Systems, Spectrophotometers/radiometers, Monochromators, Detection Systems, and Light Sources to offer to the global research community through a network of representatives.

 here

Sciencetech product design

SCIENCETECH has built a reputation on custom solutions. Whether you need a small modification to an existing system or a completely novel design built from the ground up to meet your technical specifications, Sciencetech's engineering and optical design teams are ready to help.

SCIENCETECH prides itself on our ability to build custom solutions and systems to the most exacting of specifications. Whether you need higher sensitivity, better throughput, more power, better spectral matching, higher resolution, or any other variable modified to give you exactly what you need, our team of engineers, physicists, and optical designers stand ready to provide you with a solution that will meet your technical requirements.

SCIENCETECH'S SOLAR SIMULATORS IN ACTION - The European Commission just released an article involving the use of Sciencetech's solar simulators in their new facility. Read the full article HERE.

X

Product Category

View Filter

x
Clear all x

Filter Option



A custom built sample chamber capable of both vacuum operation and a choice of temperature ranges between 77K and room temperature.
The system requires liquid nitrogen, but does not include it.

While the system will be constructed for this temperature range, the mechanisms, pumps, and other equipment is sold separately.
This Sample Chamber requires EITHER 188-8901 OR 188-8903 to complete the sample chamber. Please ask your authorized Sciencetech technical sales staff member for further information.
36,675.00
A custom built sample chamber capable of both vacuum operation and a choice of temperature ranges between 77K and room temperature.
The system requires liquid nitrogen, but does not include it.

While the system will be constructed for this temperature range, the mechanisms, pumps, and other equipment is sold separately.
This Sample Chamber requires EITHER 188-8901 OR 188-8903 to complete the sample chamber. Please ask your authorized Sciencetech technical sales staff member for further information.
36,675.00 36675.0 USD
Price Valid only in North America


A temperature control system to allow operation between 77K or room temperature.
This sisytem will come with two separate holders, each capable of holding a specific size and type of sample. They will not have the ability to rotate or moved, but will come prealigned for a fixed angle reflectivity, or transmission, through a motorized flipping mirror.
17,805.00
In stock
A temperature control system to allow operation between 77K or room temperature.
This sisytem will come with two separate holders, each capable of holding a specific size and type of sample. They will not have the ability to rotate or moved, but will come prealigned for a fixed angle reflectivity, or transmission, through a motorized flipping mirror.
17,805.00 17805.0 USD
Price Valid only in North America


.
4,000.00 4000.0 USD
Price Valid only in North America


The Sciencetech 9040 is a half meter, high performance monochromator/spectrograph. It supports large size gratings for high light throughput: three sizes are available: 64 × 64mm, 84 × 84 mm, and 102 × 102mm which allow it to achieve apertures of f/6.9, f/5.2 and f/4.0 respectively. This version is f/4.0, and suitable for use with 102 × 102mm sized ruled or holographic reflection gratings.
The 9040 is based on the Czerny-Turner optical configuration. The 9040 supports both single grating and triple grating turret configurations. This version is the single grating turret version and supports a single large size grating mounted on a rotating turret for wavelength selection. The grating is installed on a removable kinematic mount and can be manually swapped with other gratings without disruption to the optical alignment. The 9040 is also available in double additive and double subtractive versions to obtain even higher resolution or to minimize stray light.
The kinematic single grating mount (that can be exchanged with other gratings) can be upgraded to an automated three or four grating turret (F/# dependent).
This model includes a single SS-84 high-resolution manual slit at the input. If an output slit is required, it must be added separately. Motorized slits are available as an upgrade.
This monochromator is not configurable for double pass mode.
The system is configured by default for front input and output ports, but lateral or dual input and output ports can be added separately.
20,200.00
In stock
The Sciencetech 9040 is a half meter, high performance monochromator/spectrograph. It supports large size gratings for high light throughput: three sizes are available: 64 × 64mm, 84 × 84 mm, and 102 × 102mm which allow it to achieve apertures of f/6.9, f/5.2 and f/4.0 respectively. This version is f/4.0, and suitable for use with 102 × 102mm sized ruled or holographic reflection gratings.
The 9040 is based on the Czerny-Turner optical configuration. The 9040 supports both single grating and triple grating turret configurations. This version is the single grating turret version and supports a single large size grating mounted on a rotating turret for wavelength selection. The grating is installed on a removable kinematic mount and can be manually swapped with other gratings without disruption to the optical alignment. The 9040 is also available in double additive and double subtractive versions to obtain even higher resolution or to minimize stray light.
The kinematic single grating mount (that can be exchanged with other gratings) can be upgraded to an automated three or four grating turret (F/# dependent).
This model includes a single SS-84 high-resolution manual slit at the input. If an output slit is required, it must be added separately. Motorized slits are available as an upgrade.
This monochromator is not configurable for double pass mode.
The system is configured by default for front input and output ports, but lateral or dual input and output ports can be added separately.
20,200.00 20200.0 USD
Price Valid only in North America


The Sciencetech 9040 is a half meter, high performance monochromator/spectrograph. It supports large size gratings for high light throughput: three sizes are available: 64 × 64mm, 84 × 84 mm, and 102 × 102mm which allow it to achieve apertures of f/6.9, f/5.2 and f/4.0 respectively. This version is f/5.2, and suitable for use with up to 84 × 84mm sized ruled or holographic reflection gratings.
The 9040 is based on the Czerny-Turner optical configuration. The 9040 supports both single grating and triple grating turret configurations. This version is the single grating turret version and supports a single large size grating mounted on a rotating turret for wavelength selection. The grating is installed on a removable kinematic mount and can be manually swapped with other gratings without disruption to the optical alignment. The 9040 is also available in double additive and double subtractive versions to obtain even higher resolution or to minimize stray light.
The kinematic single grating mount (that can be exchanged with other gratings) can be upgraded to an automated three or four grating turret (F/# dependent).
This model includes a single SS-84 high-resolution manual slit at the input. If an output slit is required, it must be added separately. Motorized slits are available as an upgrade.
This monochromator is not configurable for double pass mode.
The system is configured by default for front input and output ports, but lateral or dual input and output ports can be added separately.
19,240.00
In stock
The Sciencetech 9040 is a half meter, high performance monochromator/spectrograph. It supports large size gratings for high light throughput: three sizes are available: 64 × 64mm, 84 × 84 mm, and 102 × 102mm which allow it to achieve apertures of f/6.9, f/5.2 and f/4.0 respectively. This version is f/5.2, and suitable for use with up to 84 × 84mm sized ruled or holographic reflection gratings.
The 9040 is based on the Czerny-Turner optical configuration. The 9040 supports both single grating and triple grating turret configurations. This version is the single grating turret version and supports a single large size grating mounted on a rotating turret for wavelength selection. The grating is installed on a removable kinematic mount and can be manually swapped with other gratings without disruption to the optical alignment. The 9040 is also available in double additive and double subtractive versions to obtain even higher resolution or to minimize stray light.
The kinematic single grating mount (that can be exchanged with other gratings) can be upgraded to an automated three or four grating turret (F/# dependent).
This model includes a single SS-84 high-resolution manual slit at the input. If an output slit is required, it must be added separately. Motorized slits are available as an upgrade.
This monochromator is not configurable for double pass mode.
The system is configured by default for front input and output ports, but lateral or dual input and output ports can be added separately.
19,240.00 19240.0 USD
Price Valid only in North America


Set of 6 optical density filters in values of 0.15, 0.3, 0.4, 0.6, 0.9, and 2.5. Each is 25mm diameter and unmounted.
These are absorption filters (as opposed to reflective neutral density).
350.00
In stock
Set of 6 optical density filters in values of 0.15, 0.3, 0.4, 0.6, 0.9, and 2.5. Each is 25mm diameter and unmounted.
These are absorption filters (as opposed to reflective neutral density).
350.00 350.0 USD
Price Valid only in North America


.Substrate dimensions: 68 x 68 x 9.5 mm
Clear aperture: 64 x 64 mm
2,000.00
In stock
.Substrate dimensions: 68 x 68 x 9.5 mm
Clear aperture: 64 x 64 mm
2,000.00 2000.0 USD
Price Valid only in North America


.Substrate dimensions: 68 x 68 x 9.5 mm
Clear aperture: 64 x 64 mm
2,000.00
In stock
.Substrate dimensions: 68 x 68 x 9.5 mm
Clear aperture: 64 x 64 mm
2,000.00 2000.0 USD
Price Valid only in North America


The PTS-4-SSP is Sciencetech’s flagship measurement system. The PTS-4 includes all the measurement extensive measurement tools and capabilities of the PTS 1,2 and 3 and adds the powerful Steady State Photoconductivity (SSP) method. Steady state photoconductivity (SSP) measurements give information about the nature of defects, mobility-lifetime products, and the transport and recombination kinetics of photogenerated carriers. Since the states between quasi-Fermi levels act predominantly as recombination centres, steady state photoconductivity is sensitive to both the density and the nature of these states.

The PTS-4-SSP uses the PTS integrated monochromatic light source to perform steady state photoconductivity measurements. To perform SSP measurements the incident flux is first measured using the provided calibrated reference detector in AC mode. After system calibration is performed the light source chopper is turned off and set to the open position for DC measurements.

Under DC illumination the photocurrent is measured at each wavelength using the included electrometer.

A relative value for the absorption coefficient can be obtained from studies of the sample using the included CPM technique.

Reflectivity measurements are not included with the system and are generally performed using a secondary instrument.

The volume generation rate can be calculated from the measured values of incident flux, the sample thickness, relative absorption coefficient and reflectivity profile. With measurements of the photocurrent and volume generation rate the steady state photoconductivity can be determined.

Please speak to a Sciencetech Technical Specialist for further information.

PTS-4-SSP Includes:

-IV Testing
-Spectral Response
-Quantum Efficiency/IPCE
-CPM Measurements
-SSP Measurements

This system includes 4 IEC 60320 C13 compatible power cables. Region-specific version must be selected at the time of placing an order (see product 491-9001).
124,500.00
In stock
The PTS-4-SSP is Sciencetech’s flagship measurement system. The PTS-4 includes all the measurement extensive measurement tools and capabilities of the PTS 1,2 and 3 and adds the powerful Steady State Photoconductivity (SSP) method. Steady state photoconductivity (SSP) measurements give information about the nature of defects, mobility-lifetime products, and the transport and recombination kinetics of photogenerated carriers. Since the states between quasi-Fermi levels act predominantly as recombination centres, steady state photoconductivity is sensitive to both the density and the nature of these states.

The PTS-4-SSP uses the PTS integrated monochromatic light source to perform steady state photoconductivity measurements. To perform SSP measurements the incident flux is first measured using the provided calibrated reference detector in AC mode. After system calibration is performed the light source chopper is turned off and set to the open position for DC measurements.

Under DC illumination the photocurrent is measured at each wavelength using the included electrometer.

A relative value for the absorption coefficient can be obtained from studies of the sample using the included CPM technique.

Reflectivity measurements are not included with the system and are generally performed using a secondary instrument.

The volume generation rate can be calculated from the measured values of incident flux, the sample thickness, relative absorption coefficient and reflectivity profile. With measurements of the photocurrent and volume generation rate the steady state photoconductivity can be determined.

Please speak to a Sciencetech Technical Specialist for further information.

PTS-4-SSP Includes:

-IV Testing
-Spectral Response
-Quantum Efficiency/IPCE
-CPM Measurements
-SSP Measurements

This system includes 4 IEC 60320 C13 compatible power cables. Region-specific version must be selected at the time of placing an order (see product 491-9001).
124,500.00 124500.0 USD
Price Valid only in North America


The PTS-3-PTD has the same capabilities to measure IV, Spectral Response, and Quantum Efficiency as the PTS-1 and PTS-2 systems, but adds the powerful photothermal deflection spectroscopy (PDS) method allowing for the direct measurement of the sub-gap absorption of the sample by utilizing the mirage effect. Please speak to a Sciencetech Technical Specialist for further information.
PTS-3-PTD Includes:
-IV Testing
-Spectral Response
-Quantum Efficiency/IPCE
-PDS Measurements

This system includes 2 IEC 60320 C13 compatible power cables. Region-specific version must be selected at the time of placing an order (see product 491-9001).
94,750.00
In stock
The PTS-3-PTD has the same capabilities to measure IV, Spectral Response, and Quantum Efficiency as the PTS-1 and PTS-2 systems, but adds the powerful photothermal deflection spectroscopy (PDS) method allowing for the direct measurement of the sub-gap absorption of the sample by utilizing the mirage effect. Please speak to a Sciencetech Technical Specialist for further information.
PTS-3-PTD Includes:
-IV Testing
-Spectral Response
-Quantum Efficiency/IPCE
-PDS Measurements

This system includes 2 IEC 60320 C13 compatible power cables. Region-specific version must be selected at the time of placing an order (see product 491-9001).
94,750.00 94750.0 USD
Price Valid only in North America


The PTS-3-DBM has the same ability to measure IV, spectral response, and quantum efficiency as the PTS-1 and PTS-2 systems, but adds the powerful technique of the dual beam photocurrent (DBM) method. The DBM system is based on maintaining constant photocurrent over the range of photon energy to get constant quasi-Fermi levels. Furthermore, the DBM system has the additional capability to vary the bias light source intensity. This changes the electron-hole and quasi-Fermi levels to yield additional information about defect states. Please speak to a Sciencetech Technical Specialist for further information.
PTS-3-DBM Includes:
-IV Testing
-Spectral Response
-Quantum Efficiency/IPCE
-DBM Measurements

This system includes 2 IEC 60320 C13 compatible power cables. Region-specific version must be selected at the time of placing an order (see product 491-9001).
93,800.00
In stock
The PTS-3-DBM has the same ability to measure IV, spectral response, and quantum efficiency as the PTS-1 and PTS-2 systems, but adds the powerful technique of the dual beam photocurrent (DBM) method. The DBM system is based on maintaining constant photocurrent over the range of photon energy to get constant quasi-Fermi levels. Furthermore, the DBM system has the additional capability to vary the bias light source intensity. This changes the electron-hole and quasi-Fermi levels to yield additional information about defect states. Please speak to a Sciencetech Technical Specialist for further information.
PTS-3-DBM Includes:
-IV Testing
-Spectral Response
-Quantum Efficiency/IPCE
-DBM Measurements

This system includes 2 IEC 60320 C13 compatible power cables. Region-specific version must be selected at the time of placing an order (see product 491-9001).
93,800.00 93800.0 USD
Price Valid only in North America


The Sciencetech 9055 is a 250mm asymmetric focal length modified Czerny-Turner monochromator. It has a flat field output for use as a spectrograph. This model has an f/3.5 aperture (for the "Fast" version with f/2.5, please see the 9055F). It has a computer-controlled interchangeable turret for automatic grating and wavelength selection.
Both the input and output ports are located on the front faceplate of the monochromator, and the system includes one SS80 slit at the input port. CE compliant.

It Includes a Sci-Mono, a Windows based software module with a simple graphical user interface for controlling Sciencetech stepping monochromator wavelength selection. SciMono is provided free of charge with a Sciencetech motorized monochromator when SciSpec software has not been purchased.

Sciencetech Software (Sci-Spec) is available at an additional cost. It is a standalone data acquisition and allows controlling the monochromator by itself.

This system does not include gratings or a host computer. If you require any of these components, please speak with your technical sales staff member.

Refer to the technical datasheet for additional information.

This system includes 1 IEC 60320 C13 compatible power cables. Region-specific version must be selected at the time of placing an order (see product 491-9001).
8,453.00
In stock
The Sciencetech 9055 is a 250mm asymmetric focal length modified Czerny-Turner monochromator. It has a flat field output for use as a spectrograph. This model has an f/3.5 aperture (for the "Fast" version with f/2.5, please see the 9055F). It has a computer-controlled interchangeable turret for automatic grating and wavelength selection.
Both the input and output ports are located on the front faceplate of the monochromator, and the system includes one SS80 slit at the input port. CE compliant.

It Includes a Sci-Mono, a Windows based software module with a simple graphical user interface for controlling Sciencetech stepping monochromator wavelength selection. SciMono is provided free of charge with a Sciencetech motorized monochromator when SciSpec software has not been purchased.

Sciencetech Software (Sci-Spec) is available at an additional cost. It is a standalone data acquisition and allows controlling the monochromator by itself.

This system does not include gratings or a host computer. If you require any of these components, please speak with your technical sales staff member.

Refer to the technical datasheet for additional information.

This system includes 1 IEC 60320 C13 compatible power cables. Region-specific version must be selected at the time of placing an order (see product 491-9001).
8,453.00 8453.0 USD
Price Valid only in North America


The PTS-3-CPM allows users the same ability to measure IV, Spectral Response, and Quantum Efficiency as the PTS-1 and PTS-2, but adds the powerful Constant Photocurrent Method (CPM). The CPM system illuminates the sample solar sell with a bias solar light source while a separate light source is modulated to cover a specified spectrum. The bias source ensures that the signal is not dominated by the non-linear response at low-level illumination, but rather gives a baseline response dependent on the wavelength of the modulated source. This allows for a highly precise measurement of defect density. Please speak with a Sciencetech Technical Specialist for more information.
PTS-3-CPM Includes:
-IV Testing
-Spectral Response
-Quantum Efficiency/IPCE
-CPM Measurements

This system includes 3 IEC 60320 C13 compatible power cables. Region-specific version must be selected at the time of placing an order (see product 491-9001).
92,500.00
In stock
The PTS-3-CPM allows users the same ability to measure IV, Spectral Response, and Quantum Efficiency as the PTS-1 and PTS-2, but adds the powerful Constant Photocurrent Method (CPM). The CPM system illuminates the sample solar sell with a bias solar light source while a separate light source is modulated to cover a specified spectrum. The bias source ensures that the signal is not dominated by the non-linear response at low-level illumination, but rather gives a baseline response dependent on the wavelength of the modulated source. This allows for a highly precise measurement of defect density. Please speak with a Sciencetech Technical Specialist for more information.
PTS-3-CPM Includes:
-IV Testing
-Spectral Response
-Quantum Efficiency/IPCE
-CPM Measurements

This system includes 3 IEC 60320 C13 compatible power cables. Region-specific version must be selected at the time of placing an order (see product 491-9001).
92,500.00 92500.0 USD
Price Valid only in North America


The 9030DA double additive monochromator consists of two 9030 monochromators placed in series. Stray light is drastically reduced in a double monochromator, and in the 9030DA it is further minimized by the use of concave holographic gratings. The inbound light is dispersed by the first grating and again by the second. Both gratings rotate simultaneously in the same direction, and in the DA the monochromators are coupled so that the dispersion is double that of a single 9030 monochromator. Bandpass is half of the corresponding 9030 monochromator for the same output slit, and resolution using a 100 µm slit is 0.4 nm.
This includes one set of standard slits, but the grating must be selected/specified separately.
Mirror coatings have been chosen for this model to enhance performance in the VIS-NIR region.
4,628.00
In stock
The 9030DA double additive monochromator consists of two 9030 monochromators placed in series. Stray light is drastically reduced in a double monochromator, and in the 9030DA it is further minimized by the use of concave holographic gratings. The inbound light is dispersed by the first grating and again by the second. Both gratings rotate simultaneously in the same direction, and in the DA the monochromators are coupled so that the dispersion is double that of a single 9030 monochromator. Bandpass is half of the corresponding 9030 monochromator for the same output slit, and resolution using a 100 µm slit is 0.4 nm.
This includes one set of standard slits, but the grating must be selected/specified separately.
Mirror coatings have been chosen for this model to enhance performance in the VIS-NIR region.
4,628.00 4628.0 USD
Price Valid only in North America


The 9150 is Sciencetech's longest single path length monochromator with a 1.5 m focal length. Under optimum conditions with a 2400 l/mm grating it can achieve a resolution of 0.004 nm in single pass mode. This model of monochromator accomodates a grating on a removable kinematic mount, allowing the user to manually swap one grating for another without losing alignment. Please note that this product includes one slit, but does not include any additional slits or a grating. These must be purchased separately. Please speak with a technical sales member for assistance in selecting the right components for your system.
Please see the technical datasheet for additional information.
61,057.00
In stock
The 9150 is Sciencetech's longest single path length monochromator with a 1.5 m focal length. Under optimum conditions with a 2400 l/mm grating it can achieve a resolution of 0.004 nm in single pass mode. This model of monochromator accomodates a grating on a removable kinematic mount, allowing the user to manually swap one grating for another without losing alignment. Please note that this product includes one slit, but does not include any additional slits or a grating. These must be purchased separately. Please speak with a technical sales member for assistance in selecting the right components for your system.
Please see the technical datasheet for additional information.
61,057.00 61057.0 USD
Price Valid only in North America


.
730.00 730.0 USD
Price Valid only in North America


.
730.00 730.0 USD
Price Valid only in North America


Sciencetech's FSSP solar simulator is designed to illuminate targets of 1x1m with 1 sun, or smaller targets with multiple suns. The default spectral match is to ASTM AM1.5G. The flash itself is a stable 1ms length, with options available (purchased separately) to stretch the pulse. Timing and number of flashes can be computer controlled. This unit is a Class AAA flash solar simulator by default, with options available to reduce spatial uniformity in order to increase target size.

Sciencetech can also offer increased spectral ranges and other additional features upon request.

This product includes a flash system, power supply, lamp, and an air mass filter (AM1.5G). Other filters are available at additional cost. Available accessories include IV measurement systems, pre-configured host computers, and sample holding and cooling options. Please inquire with Sciencetech technical support staff about our automation and assembly line manufacturing partners.

Spectral Match: Class A
Spatial Non-Uniformity: Class A
Temporal Instability: Class A
Target Size: 1m × 1m (1 Sun) (Smaller targets available at higher intensities.)
Working Distance: 5-10m
Pulse Length: 1ms (Pulse stretching available)
Collimation: 2° half angle
42,816.00
In stock
Sciencetech's FSSP solar simulator is designed to illuminate targets of 1x1m with 1 sun, or smaller targets with multiple suns. The default spectral match is to ASTM AM1.5G. The flash itself is a stable 1ms length, with options available (purchased separately) to stretch the pulse. Timing and number of flashes can be computer controlled. This unit is a Class AAA flash solar simulator by default, with options available to reduce spatial uniformity in order to increase target size.

Sciencetech can also offer increased spectral ranges and other additional features upon request.

This product includes a flash system, power supply, lamp, and an air mass filter (AM1.5G). Other filters are available at additional cost. Available accessories include IV measurement systems, pre-configured host computers, and sample holding and cooling options. Please inquire with Sciencetech technical support staff about our automation and assembly line manufacturing partners.

Spectral Match: Class A
Spatial Non-Uniformity: Class A
Temporal Instability: Class A
Target Size: 1m × 1m (1 Sun) (Smaller targets available at higher intensities.)
Working Distance: 5-10m
Pulse Length: 1ms (Pulse stretching available)
Collimation: 2° half angle
42,816.00 42816.0 USD
Price Valid only in North America


This SMA Fiber Coupler mates a Sciencetech Beam Condensing Assembly to the input end of an SMA fiber such that the light collected is focused into the SMA fiber tip with great efficiency. The SMA Fiber Coupler screws onto the output end of the Beam Condensing Assembly. Once screwed on, the input tip of the fiber bundle is positioned at the output focal spot for optimum light collection. There are two flange sizes of the Fiber Bundle Coupler available to match the 1 and 2 inch diameter sizes of the Beam Condensing Assembly. Please note that the SMA Fiber Coupler should not be used on its own without the beam condensing assembly as otherwise the light collection efficiency from the light source will be very low.
437.00
In stock
This SMA Fiber Coupler mates a Sciencetech Beam Condensing Assembly to the input end of an SMA fiber such that the light collected is focused into the SMA fiber tip with great efficiency. The SMA Fiber Coupler screws onto the output end of the Beam Condensing Assembly. Once screwed on, the input tip of the fiber bundle is positioned at the output focal spot for optimum light collection. There are two flange sizes of the Fiber Bundle Coupler available to match the 1 and 2 inch diameter sizes of the Beam Condensing Assembly. Please note that the SMA Fiber Coupler should not be used on its own without the beam condensing assembly as otherwise the light collection efficiency from the light source will be very low.
437.00 437.0 USD
Price Valid only in North America


Sciencetech’s FSSP-HC-A highly collimated flash solar simulator is capable of illuminating targets up to 1.8 × 1.5m (or 1.5m diameter) with highly collimated light (up to 0.5° half angle). This allows testing of concentrated photovoltaics (CPV) or other applications requiring extremely high collimation. Within the illuminated area, the central 1 × 1m or larger meets Class A uniformity requirements. Please speak with your Sciencetech technical support staff for Class A uniformity matching over the entire illumination area. The default spectral match is to ASTM AM1.5D.

This product includes a flash system, power supply, collimating mirror, and lamp. Air mass filters are available separately (AM1.5D and AM1.5G, with additional filters available upon request). Available accessories include IV measurement systems, pre-configured host computers, and sample holding and cooling options. Please inquire with Sciencetech technical support staff about our automation and assembly line manufacturing partners.

Spectral Match: Class A
Spatial Non-Uniformity: Class A (Central 1m × 1m)
Temporal Instability: Class A
Target Size: 1.8m × 1.5m (1 Sun)
Working Distance: 5m
Pulse Length: 500µs at 90% of peak intensity, and 2.5ms at 50% of peak intensity
Collimation: 0.5° half angle
150,000.00
In stock
Sciencetech’s FSSP-HC-A highly collimated flash solar simulator is capable of illuminating targets up to 1.8 × 1.5m (or 1.5m diameter) with highly collimated light (up to 0.5° half angle). This allows testing of concentrated photovoltaics (CPV) or other applications requiring extremely high collimation. Within the illuminated area, the central 1 × 1m or larger meets Class A uniformity requirements. Please speak with your Sciencetech technical support staff for Class A uniformity matching over the entire illumination area. The default spectral match is to ASTM AM1.5D.

This product includes a flash system, power supply, collimating mirror, and lamp. Air mass filters are available separately (AM1.5D and AM1.5G, with additional filters available upon request). Available accessories include IV measurement systems, pre-configured host computers, and sample holding and cooling options. Please inquire with Sciencetech technical support staff about our automation and assembly line manufacturing partners.

Spectral Match: Class A
Spatial Non-Uniformity: Class A (Central 1m × 1m)
Temporal Instability: Class A
Target Size: 1.8m × 1.5m (1 Sun)
Working Distance: 5m
Pulse Length: 500µs at 90% of peak intensity, and 2.5ms at 50% of peak intensity
Collimation: 0.5° half angle
150,000.00 150000.0 USD
Price Valid only in North America
Copyright © Sciencetech