The Sciencetech PMH-01 Photon Counting Module is self-contained compact unit incorporating PMT tube, high-speed amplifier, discriminator, and high voltage power supply. The output signal (train of pulses, the number of which corresponds to the number of detected photons) can be sent via a BNC connector, to an external counting/displaying circuit. The PMH-01 outputs digital signal (pulses) only. There is no analog output port.

The photon counting head used has low power consumption (max 0.5W). It is already adjusted for best S/N ratio. There is no additional adjustment necessary to start the operation.

Parameter Value
Operating Temperature Range +5 to + 40 °C
Storage Temperature Range -20 to +50 °C
Effective Area 4 x 6 sq.mm
Spectral Response 185 to 900 nm
Dark Count (Typical) 400 cps
Dark Count (Max.) 800 cps
Counting Linearity 2.5 Mcps
Pulse Pair Resolution 35 ns
Output Pulse Width 30 ns
Output Logic TTL, positive
Input Voltage +5 V
Input Current at 2.5 Mcps Output max. 80 mA
Output Signal Cable RG-174/U
4,000.00
In stock
The Sciencetech PMH-01 Photon Counting Module is self-contained compact unit incorporating PMT tube, high-speed amplifier, discriminator, and high voltage power supply. The output signal (train of pulses, the number of which corresponds to the number of detected photons) can be sent via a BNC connector, to an external counting/displaying circuit. The PMH-01 outputs digital signal (pulses) only. There is no analog output port.

The photon counting head used has low power consumption (max 0.5W). It is already adjusted for best S/N ratio. There is no additional adjustment necessary to start the operation.

Parameter Value
Operating Temperature Range +5 to + 40 °C
Storage Temperature Range -20 to +50 °C
Effective Area 4 x 6 sq.mm
Spectral Response 185 to 900 nm
Dark Count (Typical) 400 cps
Dark Count (Max.) 800 cps
Counting Linearity 2.5 Mcps
Pulse Pair Resolution 35 ns
Output Pulse Width 30 ns
Output Logic TTL, positive
Input Voltage +5 V
Input Current at 2.5 Mcps Output max. 80 mA
Output Signal Cable RG-174/U
4,000.00 4000.0 USD
Price Valid only in North America


Sciencetech's Compact 1.75" Optical Liquid Filter is designed to filter wavelengths 1000nm and greater (if distilled water is used). The compact size allows it to be installed in one of Sciencetech's FH- style filter boxes. This filter requires a cooling water recirculator (sold separately).
1,099.00
In stock
Sciencetech's Compact 1.75" Optical Liquid Filter is designed to filter wavelengths 1000nm and greater (if distilled water is used). The compact size allows it to be installed in one of Sciencetech's FH- style filter boxes. This filter requires a cooling water recirculator (sold separately).
1,099.00 1099.0 USD
Price Valid only in North America


The Sciencetech variable focus assembly is coupled to the output port of Model 201-1K arc lamp housing for refocusing its collimated light into a divergent spot. An adjustable lever is used to move the 4 lens assembly along the optical axis. The output beam can be refocused at any f number from infinity (collimated) to f/2. This feature can be used as an intensity controller as the light can be concentrated to any size spot larger or smaller than the 2" diameter of the output port.

To adjust the focus simply use the handles provided to slide the lens tube in or out of the lamp housing. Note that the lens tube has approximately 1” of travel. Stoppers on either end of the lens tube prevent the lens tube from contacting the lamp or from being pulled out of the lamp house.

This assembly uses UV-Fused Silica lenses for optimal UV light transmission.
1,870.00
The Sciencetech variable focus assembly is coupled to the output port of Model 201-1K arc lamp housing for refocusing its collimated light into a divergent spot. An adjustable lever is used to move the 4 lens assembly along the optical axis. The output beam can be refocused at any f number from infinity (collimated) to f/2. This feature can be used as an intensity controller as the light can be concentrated to any size spot larger or smaller than the 2" diameter of the output port.

To adjust the focus simply use the handles provided to slide the lens tube in or out of the lamp housing. Note that the lens tube has approximately 1” of travel. Stoppers on either end of the lens tube prevent the lens tube from contacting the lamp or from being pulled out of the lamp house.

This assembly uses UV-Fused Silica lenses for optimal UV light transmission.
1,870.00 1870.0 USD
Price Valid only in North America


A 300W xenon short arc lamp bulb, using a fused silica glass envelope. Please note that this lamp produces ozone.
1,350.00
In stock
A 300W xenon short arc lamp bulb, using a fused silica glass envelope. Please note that this lamp produces ozone.
1,350.00 1350.0 USD
Price Valid only in North America


This is a high resolution slit designed to have 10 um resolution. The slits are manufactured from stainless steel to maximize mechanical accuracy. The height of the SS-84 slit can also be adjusted between 0-10 mm, 10-20 mm and 20-30 mm through built-in manual curtain sliders.

Please note that these slits are not designed to maximize throughput for extremely high resolution monochromators, due to the straight orientation of the slits. For maximum resolution, the slits need to be designed on a curve that corresponds to the curvature of the point of least confusion. However, this is only a significant factor for systems with optical pathlengths of 1m and greater. Please speak with your authorized Sciencetech technical sales staff member if you need maximum resolution for a long pathlength system.
1,030.00
In stock
This is a high resolution slit designed to have 10 um resolution. The slits are manufactured from stainless steel to maximize mechanical accuracy. The height of the SS-84 slit can also be adjusted between 0-10 mm, 10-20 mm and 20-30 mm through built-in manual curtain sliders.

Please note that these slits are not designed to maximize throughput for extremely high resolution monochromators, due to the straight orientation of the slits. For maximum resolution, the slits need to be designed on a curve that corresponds to the curvature of the point of least confusion. However, this is only a significant factor for systems with optical pathlengths of 1m and greater. Please speak with your authorized Sciencetech technical sales staff member if you need maximum resolution for a long pathlength system.
1,030.00 1030.0 USD
Price Valid only in North America


This standard optical liquid filter is equipped with BK7 windows (350 to 2000 nm). Can be operated either horizontally or vertically but horizontal operation is preferable due to potential risk of air gap in the light path. Stainless steel provides superior corrosion resistance compared to aluminum for corrosive liquids.
2,199.00
In stock
This standard optical liquid filter is equipped with BK7 windows (350 to 2000 nm). Can be operated either horizontally or vertically but horizontal operation is preferable due to potential risk of air gap in the light path. Stainless steel provides superior corrosion resistance compared to aluminum for corrosive liquids.
2,199.00 2199.0 USD
Price Valid only in North America


This standard optical liquid filter is equipped with fused quartz windows (270 to 2500 nm) which transmit UV light. This allows it to be used for UV applications. Can be operated either horizontally or vertically but horizontal operation is preferable due to potential risk of air gap in the light path. Stainless steel provides superior corrosion resistance compared to aluminum for corrosive liquids.
2,199.00
In stock
This standard optical liquid filter is equipped with fused quartz windows (270 to 2500 nm) which transmit UV light. This allows it to be used for UV applications. Can be operated either horizontally or vertically but horizontal operation is preferable due to potential risk of air gap in the light path. Stainless steel provides superior corrosion resistance compared to aluminum for corrosive liquids.
2,199.00 2199.0 USD
Price Valid only in North America


This is a coupling tube, without optics, designed to hold lenses for integrating systems. In most cases, a customer will require [120-8036] as it includes the optical components required to couple effectively.
99.00
In stock
This is a coupling tube, without optics, designed to hold lenses for integrating systems. In most cases, a customer will require [120-8036] as it includes the optical components required to couple effectively.
99.00 99.0 USD
Price Valid only in North America


Slip ring for coupling 2" diameter lens tubes to a Sciencetech S4 hole pattern.
99.00
In stock
Slip ring for coupling 2" diameter lens tubes to a Sciencetech S4 hole pattern.
99.00 99.0 USD
Price Valid only in North America


This filter set consists of three wire-mesh neutral-density filters to be installed in the filter wheel. This filter set is designed to be used with the Sciencetech's Solar Lightline fiber-based solar simulator. Optical density of each filter is selected such that the final beam output from the light guide and collimator will be selectable at 0.25, 0.5, 0.75 and 1 of maximum irradiance for the AX Lightline system.
350.00
In stock
This filter set consists of three wire-mesh neutral-density filters to be installed in the filter wheel. This filter set is designed to be used with the Sciencetech's Solar Lightline fiber-based solar simulator. Optical density of each filter is selected such that the final beam output from the light guide and collimator will be selectable at 0.25, 0.5, 0.75 and 1 of maximum irradiance for the AX Lightline system.
350.00 350.0 USD
Price Valid only in North America


Sciencetech's Model [210-REC] is a Cooling Water Recirculator. It can sink up to 2500W of heat.

-Dissipates up to 2500W of thermal heat
-External fan cooled radiator system
-Cools to ambient temperature
-Real time sample temperature display (in °C or °F)
-Adjustable cooling rate

Sciencetech's Model [210-REC] is a Cooling Water Recirculator. It can sink up to 2500W of heat.

-Dissipates up to 2500W of thermal heat
-External fan cooled radiator system
-Cools to ambient temperature
-Real time sample temperature display (in °C or °F)
-Adjustable cooling rate

2,200.00 2200.0 USD
Price Valid only in North America


This product consists of the Sciencetech SOL-METER and our SSIVT-REF sun calibrated reference detector. The SOL-METER is a digital meter for use with solar calibrated detectors such as detector models SSIVT-REF or SC-LT. The meter converts detector measurements to a Sun value. It has a handheld meter that is compact, has a sturdy design, and is appropriate for indoor or outdoor applications.

The Sciencetech Reference Detector, which is an integral part of solar simulator calibration and solar cell I-V characterization, consists of a single element silicon detector and is designed to be used for monitoring and verifying the Sun level of solar simulators. The SSIVT-REF detector is used effective in sensing wavelengths between 190 nm and 1100 nm and is calibrated at Sciencetech against a NIST traceable calibrated reference cell. Comes with a detachable cable with 4 banana plugs for connecting to a measurement device. CE compliant.

Rise time: 0.2 μs
Effective active area: 5.7 sqmm
Dimensions: 50.8 x 50.8 x 25.4 mm
2,800.00
In stock
This product consists of the Sciencetech SOL-METER and our SSIVT-REF sun calibrated reference detector. The SOL-METER is a digital meter for use with solar calibrated detectors such as detector models SSIVT-REF or SC-LT. The meter converts detector measurements to a Sun value. It has a handheld meter that is compact, has a sturdy design, and is appropriate for indoor or outdoor applications.

The Sciencetech Reference Detector, which is an integral part of solar simulator calibration and solar cell I-V characterization, consists of a single element silicon detector and is designed to be used for monitoring and verifying the Sun level of solar simulators. The SSIVT-REF detector is used effective in sensing wavelengths between 190 nm and 1100 nm and is calibrated at Sciencetech against a NIST traceable calibrated reference cell. Comes with a detachable cable with 4 banana plugs for connecting to a measurement device. CE compliant.

Rise time: 0.2 μs
Effective active area: 5.7 sqmm
Dimensions: 50.8 x 50.8 x 25.4 mm
2,800.00 2800.0 USD
Price Valid only in North America


The SOL-METER is a digital meter for use with solar calibrated detectors such as detector models SSIVT-REF or SOL-REF-Q. The meter converts detector measurements to a Sun value. It has a handheld meter that is compact, has a sturdy design, and is appropriate for indoor or outdoor applications. CE compliant.

Please refer to the technical datasheet for additional information.
2,212.00
In stock
The SOL-METER is a digital meter for use with solar calibrated detectors such as detector models SSIVT-REF or SOL-REF-Q. The meter converts detector measurements to a Sun value. It has a handheld meter that is compact, has a sturdy design, and is appropriate for indoor or outdoor applications. CE compliant.

Please refer to the technical datasheet for additional information.
2,212.00 2212.0 USD
Price Valid only in North America


Sciencetech is proud to offer a wide range of gratings in various sizes.
We are also happy to find custom gratings for highly specialized applications. If you feel one of the standard gratings we offer will not be sufficient for your specific application, please speak with one of our authorized Sciencetech technical sales staff members about your needs!
1,100.00
In stock
Sciencetech is proud to offer a wide range of gratings in various sizes.
We are also happy to find custom gratings for highly specialized applications. If you feel one of the standard gratings we offer will not be sufficient for your specific application, please speak with one of our authorized Sciencetech technical sales staff members about your needs!
1,100.00 1100.0 USD
Price Valid only in North America


The Sciencetech Polarizing variable frequency optical chopper is used with the detectors during Martin-Puplett mode. The chopper is positioned in front of the output port, and captures the output at 45 degrees from the two planes of polarization. This facilitates the retrieval of the Fourier Transform Interferogram during M-P mode. The chopper itself is designed for high stability and a broad range of frequency control (from 0.5Hz to 100Hz). The price includes the servo motor and software controller.
4,908.00
The Sciencetech Polarizing variable frequency optical chopper is used with the detectors during Martin-Puplett mode. The chopper is positioned in front of the output port, and captures the output at 45 degrees from the two planes of polarization. This facilitates the retrieval of the Fourier Transform Interferogram during M-P mode. The chopper itself is designed for high stability and a broad range of frequency control (from 0.5Hz to 100Hz). The price includes the servo motor and software controller.
4,908.00 4908.0 USD
Price Valid only in North America


This holder is economical choice for slits for Sciencetech monochromators such as the 9055.
This slit holder is required when using the fixed slits designed for the 9030 (Product Numbers 120-9010, 120-9011, 120-9012, 120-9013, 120-9033, and 120-9034).

Only one slit holder is required per input/output; different slits can be exchanged using the same slit holder. Please add the size of slit you would like to the order. Sizes are available from 0.05 mm (50 um) up to 3 mm. Slits are 8 mm tall.
285.00
In stock
This holder is economical choice for slits for Sciencetech monochromators such as the 9055.
This slit holder is required when using the fixed slits designed for the 9030 (Product Numbers 120-9010, 120-9011, 120-9012, 120-9013, 120-9033, and 120-9034).

Only one slit holder is required per input/output; different slits can be exchanged using the same slit holder. Please add the size of slit you would like to the order. Sizes are available from 0.05 mm (50 um) up to 3 mm. Slits are 8 mm tall.
285.00 285.0 USD
Price Valid only in North America


This mount will attach cryogenic detectors directly to a Sciencetech monochromator or spectrometer. Please note that this mount is designed specifically for cryogenically cooled detectors, and may not function for other types of detectors. If you are uncertain about whether you need this mount or not, please contact your Sciencetech Representative.
525.00
In stock
This mount will attach cryogenic detectors directly to a Sciencetech monochromator or spectrometer. Please note that this mount is designed specifically for cryogenically cooled detectors, and may not function for other types of detectors. If you are uncertain about whether you need this mount or not, please contact your Sciencetech Representative.
525.00 525.0 USD
Price Valid only in North America


The NIR-PMT is contained in a thermally insulated, sealed-off housing evacuated to a high vacuum. Simple operation by air cooled TE cooler. It is a high sensitivity detector with a large detection area of 18mm for collimated light. It includes a HV power supply with interlock function.
Fast response time
Rise Time: 900 ps
TTS: 300 ps
This unit includes the housing, power supply, and detector components, but does not include mounting to a monochromator or sample chamber. Please include mounting separately.
44,625.00
In stock
The NIR-PMT is contained in a thermally insulated, sealed-off housing evacuated to a high vacuum. Simple operation by air cooled TE cooler. It is a high sensitivity detector with a large detection area of 18mm for collimated light. It includes a HV power supply with interlock function.
Fast response time
Rise Time: 900 ps
TTS: 300 ps
This unit includes the housing, power supply, and detector components, but does not include mounting to a monochromator or sample chamber. Please include mounting separately.
44,625.00 44625.0 USD
Price Valid only in North America


This high-powered filter blocks UV light below 320 nm. This filter is designed for 0 degree angle of incidence. This filter is mounted in a FT style filter holder and has a clear aperture of 73 mm diameter.
400.00
In stock
This high-powered filter blocks UV light below 320 nm. This filter is designed for 0 degree angle of incidence. This filter is mounted in a FT style filter holder and has a clear aperture of 73 mm diameter.
400.00 400.0 USD
Price Valid only in North America


.
500.00 500.0 USD
Price Valid only in North America
Copyright © Sciencetech